{"title":"站立骨盆倾斜与跑步时的动态骨盆倾斜有关,这是通过三维运动捕捉来测量的。","authors":"Madison S Mach,&nbsp;Kyle T Ebersole,&nbsp;Hayley E Ericksen,&nbsp;Anh-Dung Nguyen,&nbsp;Jennifer E Earl-Boehm","doi":"10.1123/jab.2022-0226","DOIUrl":null,"url":null,"abstract":"<p><p>Standing pelvic tilt (PT) is related to biomechanics linked with increased risk of injury such as dynamic knee valgus. However, there is limited evidence on how standing PT relates to dynamic PT and whether the palpation meter (PALM), a tool to measure standing PT, is valid against 3-dimensional (3D) motion analysis. The purposes of this study were to (1) determine the criterion validity of the PALM for measuring standing PT and (2) identify the relationship between standing PT and dynamic PT during running. Participants (n = 25; 10 males and 15 females) had their standing PT measured by the PALM and 3D motion analysis. Dynamic PT variables were defined at initial contact and toe off. No relationship between the 2 tools was found. Significant large positive relationships between standing PT and PT at initial contact (r = .751, N = 25, P < .001) and PT at toe off (r = .761, N = 25, P < .001) were found. Since no relationship was found between standing PT measured by the PALM and 3D motion analysis, the PALM is not a valid alternative to 3D motion analysis. Clinicians may be able to measure standing PT and gain valuable information on dynamic PT, allowing clinicians to quickly assess whether further biomechanical testing is needed.</p>","PeriodicalId":54883,"journal":{"name":"Journal of Applied Biomechanics","volume":"39 4","pages":"230-236"},"PeriodicalIF":1.1000,"publicationDate":"2023-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Standing Pelvic Tilt Is Associated With Dynamic Pelvic Tilt During Running When Measured by 3-Dimensional Motion Capture.\",\"authors\":\"Madison S Mach,&nbsp;Kyle T Ebersole,&nbsp;Hayley E Ericksen,&nbsp;Anh-Dung Nguyen,&nbsp;Jennifer E Earl-Boehm\",\"doi\":\"10.1123/jab.2022-0226\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Standing pelvic tilt (PT) is related to biomechanics linked with increased risk of injury such as dynamic knee valgus. However, there is limited evidence on how standing PT relates to dynamic PT and whether the palpation meter (PALM), a tool to measure standing PT, is valid against 3-dimensional (3D) motion analysis. The purposes of this study were to (1) determine the criterion validity of the PALM for measuring standing PT and (2) identify the relationship between standing PT and dynamic PT during running. Participants (n = 25; 10 males and 15 females) had their standing PT measured by the PALM and 3D motion analysis. Dynamic PT variables were defined at initial contact and toe off. No relationship between the 2 tools was found. Significant large positive relationships between standing PT and PT at initial contact (r = .751, N = 25, P < .001) and PT at toe off (r = .761, N = 25, P < .001) were found. Since no relationship was found between standing PT measured by the PALM and 3D motion analysis, the PALM is not a valid alternative to 3D motion analysis. Clinicians may be able to measure standing PT and gain valuable information on dynamic PT, allowing clinicians to quickly assess whether further biomechanical testing is needed.</p>\",\"PeriodicalId\":54883,\"journal\":{\"name\":\"Journal of Applied Biomechanics\",\"volume\":\"39 4\",\"pages\":\"230-236\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2023-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Applied Biomechanics\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1123/jab.2022-0226\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Biomechanics","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1123/jab.2022-0226","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

站立骨盆倾斜(PT)与生物力学有关,与动态膝外翻等损伤风险增加有关。然而,关于站立PT与动态PT之间的关系,以及测量站立PT的触诊仪(PALM)是否适用于三维(3D)运动分析,证据有限。本研究的目的是:(1)确定PALM测量站立PT的标准效度;(2)确定跑步时站立PT与动态PT之间的关系。参与者(n = 25;10名男性和15名女性)通过PALM和3D运动分析测量了他们的站立PT。在初始接触和脚趾脱落时定义动态PT变量。没有发现这两种工具之间的关系。站立PT与初次接触PT (r = .751, N = 25, P < .001)和脚尖PT (r = .761, N = 25, P < .001)呈显著正相关。由于没有发现PALM测量的站立PT与3D运动分析之间的关系,因此PALM不是3D运动分析的有效替代方案。临床医生可能能够测量站立PT并获得动态PT的有价值信息,从而使临床医生能够快速评估是否需要进一步的生物力学测试。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Standing Pelvic Tilt Is Associated With Dynamic Pelvic Tilt During Running When Measured by 3-Dimensional Motion Capture.

Standing pelvic tilt (PT) is related to biomechanics linked with increased risk of injury such as dynamic knee valgus. However, there is limited evidence on how standing PT relates to dynamic PT and whether the palpation meter (PALM), a tool to measure standing PT, is valid against 3-dimensional (3D) motion analysis. The purposes of this study were to (1) determine the criterion validity of the PALM for measuring standing PT and (2) identify the relationship between standing PT and dynamic PT during running. Participants (n = 25; 10 males and 15 females) had their standing PT measured by the PALM and 3D motion analysis. Dynamic PT variables were defined at initial contact and toe off. No relationship between the 2 tools was found. Significant large positive relationships between standing PT and PT at initial contact (r = .751, N = 25, P < .001) and PT at toe off (r = .761, N = 25, P < .001) were found. Since no relationship was found between standing PT measured by the PALM and 3D motion analysis, the PALM is not a valid alternative to 3D motion analysis. Clinicians may be able to measure standing PT and gain valuable information on dynamic PT, allowing clinicians to quickly assess whether further biomechanical testing is needed.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Applied Biomechanics
Journal of Applied Biomechanics 医学-工程:生物医学
CiteScore
2.00
自引率
0.00%
发文量
47
审稿时长
6-12 weeks
期刊介绍: The mission of the Journal of Applied Biomechanics (JAB) is to disseminate the highest quality peer-reviewed studies that utilize biomechanical strategies to advance the study of human movement. Areas of interest include clinical biomechanics, gait and posture mechanics, musculoskeletal and neuromuscular biomechanics, sport mechanics, and biomechanical modeling. Studies of sport performance that explicitly generalize to broader activities, contribute substantially to fundamental understanding of human motion, or are in a sport that enjoys wide participation, are welcome. Also within the scope of JAB are studies using biomechanical strategies to investigate the structure, control, function, and state (health and disease) of animals.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信