血色素和伊红染色有助于减少用于水滴形痣诊断的短串联重复基因分型中的母体污染。

IF 1.6 4区 医学 Q3 OBSTETRICS & GYNECOLOGY
Yating Zhao, Luya Cai, Xiaofei Zhang, Huifang Zhang, Limeng Cai, Lin Zhou, Bo Huang, Jianhua Qian
{"title":"血色素和伊红染色有助于减少用于水滴形痣诊断的短串联重复基因分型中的母体污染。","authors":"Yating Zhao, Luya Cai, Xiaofei Zhang, Huifang Zhang, Limeng Cai, Lin Zhou, Bo Huang, Jianhua Qian","doi":"10.1097/PGP.0000000000000973","DOIUrl":null,"url":null,"abstract":"<p><p>Short tandem repeat (STR) genotyping provides parental origin information about aneuploidy pregnancy loss and has become the current gold standard for hydatidiform mole diagnosis. STR genotyping diagnostic support most commonly relies on formalin-fixed paraffin-embedded samples, but maternal contamination is one of the most common issues based on traditional unstained sections. To evaluate the influence of hematoxylin and eosin (H&E) staining on DNA quality and STR genotyping, DNA was isolated from unstained, deparaffinized hydrated, and H&E-stained tissue sections (i.e. 3 groups) from each of 6 formalin-fixed paraffin-embedded placentas. The macrodissected view field, DNA quality, and polymerase chain reaction amplification efficiency were compared among groups. STR genotyping analysis was performed in both the test cohort (n = 6) and the validation cohort (n = 149). H&E staining not only did not interfere with molecular DNA testing of formalin-fixed paraffin-embedded tissue but also had a clearer macrodissected field of vision. In the test cohort, H&E-stained sections were the only group that did not exhibit maternal miscellaneous peaks in STR genotyping results. In the validation cohort, 138 (92.62%) cases yielded satisfactory amplification results without maternal contamination. Thus, H&E staining helped to reduce maternal contamination in STR genotyping for hydatidiform mole diagnosis, suggesting that H&E-stained sections can be incorporated into the hydatidiform mole molecular diagnostic workflow.</p>","PeriodicalId":14001,"journal":{"name":"International Journal of Gynecological Pathology","volume":" ","pages":"253-263"},"PeriodicalIF":1.6000,"publicationDate":"2024-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11022989/pdf/","citationCount":"0","resultStr":"{\"title\":\"Hematoxylin and Eosin Staining Helps Reduce Maternal Contamination in Short Tandem Repeat Genotyping for Hydatidiform Mole Diagnosis.\",\"authors\":\"Yating Zhao, Luya Cai, Xiaofei Zhang, Huifang Zhang, Limeng Cai, Lin Zhou, Bo Huang, Jianhua Qian\",\"doi\":\"10.1097/PGP.0000000000000973\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Short tandem repeat (STR) genotyping provides parental origin information about aneuploidy pregnancy loss and has become the current gold standard for hydatidiform mole diagnosis. STR genotyping diagnostic support most commonly relies on formalin-fixed paraffin-embedded samples, but maternal contamination is one of the most common issues based on traditional unstained sections. To evaluate the influence of hematoxylin and eosin (H&E) staining on DNA quality and STR genotyping, DNA was isolated from unstained, deparaffinized hydrated, and H&E-stained tissue sections (i.e. 3 groups) from each of 6 formalin-fixed paraffin-embedded placentas. The macrodissected view field, DNA quality, and polymerase chain reaction amplification efficiency were compared among groups. STR genotyping analysis was performed in both the test cohort (n = 6) and the validation cohort (n = 149). H&E staining not only did not interfere with molecular DNA testing of formalin-fixed paraffin-embedded tissue but also had a clearer macrodissected field of vision. In the test cohort, H&E-stained sections were the only group that did not exhibit maternal miscellaneous peaks in STR genotyping results. In the validation cohort, 138 (92.62%) cases yielded satisfactory amplification results without maternal contamination. Thus, H&E staining helped to reduce maternal contamination in STR genotyping for hydatidiform mole diagnosis, suggesting that H&E-stained sections can be incorporated into the hydatidiform mole molecular diagnostic workflow.</p>\",\"PeriodicalId\":14001,\"journal\":{\"name\":\"International Journal of Gynecological Pathology\",\"volume\":\" \",\"pages\":\"253-263\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2024-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11022989/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Gynecological Pathology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/PGP.0000000000000973\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/8/11 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"OBSTETRICS & GYNECOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Gynecological Pathology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/PGP.0000000000000973","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/8/11 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"OBSTETRICS & GYNECOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

短串联重复(STR)基因分型可提供有关非整倍体妊娠损失的亲本来源信息,已成为目前诊断水滴形痣的金标准。STR 基因分型诊断支持通常依赖于福尔马林固定的石蜡包埋样本,但基于传统的未染色切片,母体污染是最常见的问题之一。为了评估苏木精和伊红(H&E)染色对 DNA 质量和 STR 基因分型的影响,我们从 6 个福尔马林固定石蜡包埋胎盘的未染色、去石蜡水合和 H&E 染色组织切片(即 3 组)中各分离出 DNA。比较各组的大切片视野、DNA 质量和聚合酶链反应扩增效率。对测试组(n = 6)和验证组(n = 149)进行了 STR 基因分型分析。H&E 染色不仅不会干扰福尔马林固定石蜡包埋组织的 DNA 分子检测,而且大切片视野更清晰。在测试人群中,H&E 染色切片是唯一没有在 STR 基因分型结果中出现母体杂峰的组别。在验证组群中,138 个(92.62%)病例的扩增结果令人满意,没有出现母体污染。因此,H&E 染色有助于减少水滴形痣诊断 STR 基因分型中的母体污染,建议将 H&E 染色切片纳入水滴形痣分子诊断工作流程。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Hematoxylin and Eosin Staining Helps Reduce Maternal Contamination in Short Tandem Repeat Genotyping for Hydatidiform Mole Diagnosis.

Short tandem repeat (STR) genotyping provides parental origin information about aneuploidy pregnancy loss and has become the current gold standard for hydatidiform mole diagnosis. STR genotyping diagnostic support most commonly relies on formalin-fixed paraffin-embedded samples, but maternal contamination is one of the most common issues based on traditional unstained sections. To evaluate the influence of hematoxylin and eosin (H&E) staining on DNA quality and STR genotyping, DNA was isolated from unstained, deparaffinized hydrated, and H&E-stained tissue sections (i.e. 3 groups) from each of 6 formalin-fixed paraffin-embedded placentas. The macrodissected view field, DNA quality, and polymerase chain reaction amplification efficiency were compared among groups. STR genotyping analysis was performed in both the test cohort (n = 6) and the validation cohort (n = 149). H&E staining not only did not interfere with molecular DNA testing of formalin-fixed paraffin-embedded tissue but also had a clearer macrodissected field of vision. In the test cohort, H&E-stained sections were the only group that did not exhibit maternal miscellaneous peaks in STR genotyping results. In the validation cohort, 138 (92.62%) cases yielded satisfactory amplification results without maternal contamination. Thus, H&E staining helped to reduce maternal contamination in STR genotyping for hydatidiform mole diagnosis, suggesting that H&E-stained sections can be incorporated into the hydatidiform mole molecular diagnostic workflow.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.90
自引率
12.50%
发文量
154
审稿时长
6-12 weeks
期刊介绍: International Journal of Gynecological Pathology is the official journal of the International Society of Gynecological Pathologists (ISGyP), and provides complete and timely coverage of advances in the understanding and management of gynecological disease. Emphasis is placed on investigations in the field of anatomic pathology. Articles devoted to experimental or animal pathology clearly relevant to an understanding of human disease are published, as are pathological and clinicopathological studies and individual case reports that offer new insights.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信