{"title":"应用PuraStat®2小时后的内镜图像:止血夹失败后使用PuraStat®实现胃后病变活检出血的止血病例。","authors":"Yoshitsugu Misumi, Kouichi Nonaka, Maiko Kishino","doi":"10.1155/2023/5620348","DOIUrl":null,"url":null,"abstract":"<p><p>PuraStat® (3D Matrix, Tokyo, Japan) is a novel, self-assembling peptide hemostatic hydrogel that can be used endoscopically. Hemostasis can be physically obtained by covering bleeding points; however, there are no reports of how long PuraStat remains in the upper gastrointestinal tract. Herein, we report a case wherein esophagogastroduodenoscopy (EGD) was performed 2 hours after PuraStat application. A 73-year-old man underwent EGD for evaluation of lesions in the posterior wall of the stomach. A biopsy was then performed on the gastric lesions; however, massive bleeding occurred. A hemostatic clip was used to stop bleeding but failed; primary hemostasis was obtained by applying PuraStat. EGD performed 2 hours later to determine whether the patient could be discharged revealed that the white-turning PuraStat gel remained firmly in the applied area, confirming complete hemostasis. PuraStat is a hemostatic agent capable of physical hemostasis that reliably remains in the stomach even after a few hours of use and, thus, may replace some conventional hemostasis methods.</p>","PeriodicalId":45645,"journal":{"name":"Case Reports in Gastrointestinal Medicine","volume":"2023 ","pages":"5620348"},"PeriodicalIF":0.6000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10397489/pdf/","citationCount":"1","resultStr":"{\"title\":\"Endoscopic Image 2 Hours after PuraStat® Application: A Case of Achieving Hemostasis Using PuraStat® for Postgastric Lesion Biopsy Bleeding after Hemostatic Clips Failed.\",\"authors\":\"Yoshitsugu Misumi, Kouichi Nonaka, Maiko Kishino\",\"doi\":\"10.1155/2023/5620348\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>PuraStat® (3D Matrix, Tokyo, Japan) is a novel, self-assembling peptide hemostatic hydrogel that can be used endoscopically. Hemostasis can be physically obtained by covering bleeding points; however, there are no reports of how long PuraStat remains in the upper gastrointestinal tract. Herein, we report a case wherein esophagogastroduodenoscopy (EGD) was performed 2 hours after PuraStat application. A 73-year-old man underwent EGD for evaluation of lesions in the posterior wall of the stomach. A biopsy was then performed on the gastric lesions; however, massive bleeding occurred. A hemostatic clip was used to stop bleeding but failed; primary hemostasis was obtained by applying PuraStat. EGD performed 2 hours later to determine whether the patient could be discharged revealed that the white-turning PuraStat gel remained firmly in the applied area, confirming complete hemostasis. PuraStat is a hemostatic agent capable of physical hemostasis that reliably remains in the stomach even after a few hours of use and, thus, may replace some conventional hemostasis methods.</p>\",\"PeriodicalId\":45645,\"journal\":{\"name\":\"Case Reports in Gastrointestinal Medicine\",\"volume\":\"2023 \",\"pages\":\"5620348\"},\"PeriodicalIF\":0.6000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10397489/pdf/\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Case Reports in Gastrointestinal Medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1155/2023/5620348\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"GASTROENTEROLOGY & HEPATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Case Reports in Gastrointestinal Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2023/5620348","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
引用次数: 1
摘要
PuraStat®(3D Matrix, Tokyo, Japan)是一种新型的自组装肽止血水凝胶,可用于内窥镜检查。止血可以通过遮盖出血点来实现;然而,没有PuraStat在上胃肠道停留多久的报道。在此,我们报告一例在应用PuraStat 2小时后进行食管胃十二指肠镜检查的病例。一位73岁的男性接受EGD评估胃后壁病变。然后对胃病变进行活检;然而,发生了大量出血。止血夹止血失败;应用PuraStat获得初步止血。2小时后进行EGD以确定患者是否可以出院,结果显示变白的PuraStat凝胶牢固地停留在应用区域,确认完全止血。PuraStat是一种能够物理止血的止血剂,即使在使用几个小时后仍能可靠地留在胃中,因此可以取代一些传统的止血方法。
Endoscopic Image 2 Hours after PuraStat® Application: A Case of Achieving Hemostasis Using PuraStat® for Postgastric Lesion Biopsy Bleeding after Hemostatic Clips Failed.
PuraStat® (3D Matrix, Tokyo, Japan) is a novel, self-assembling peptide hemostatic hydrogel that can be used endoscopically. Hemostasis can be physically obtained by covering bleeding points; however, there are no reports of how long PuraStat remains in the upper gastrointestinal tract. Herein, we report a case wherein esophagogastroduodenoscopy (EGD) was performed 2 hours after PuraStat application. A 73-year-old man underwent EGD for evaluation of lesions in the posterior wall of the stomach. A biopsy was then performed on the gastric lesions; however, massive bleeding occurred. A hemostatic clip was used to stop bleeding but failed; primary hemostasis was obtained by applying PuraStat. EGD performed 2 hours later to determine whether the patient could be discharged revealed that the white-turning PuraStat gel remained firmly in the applied area, confirming complete hemostasis. PuraStat is a hemostatic agent capable of physical hemostasis that reliably remains in the stomach even after a few hours of use and, thus, may replace some conventional hemostasis methods.