Katriina Paasikallio, Reijo Sund, Simo Miettinen, Sonja Kauranen, Hannu Sorsa, Heikki Kröger, Joonas Sirola
{"title":"桡骨远端骨折位错测量的观察者内部和观察者之间的一致性。","authors":"Katriina Paasikallio, Reijo Sund, Simo Miettinen, Sonja Kauranen, Hannu Sorsa, Heikki Kröger, Joonas Sirola","doi":"10.2340/17453674.2023.13707","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and purpose: </strong>Most displaced distal radius fractures (DRF) are treated nonoperatively, with reduction and immobilization in a cast. Studies assessing intra- or inter-observer agreement on radiologic measurements of casting position have not been published, which was the aim of our study.</p><p><strong>Patients and methods: </strong>Our study is based on the Kuopio Osteoporosis Risk Factor and Prevention (OSTPRE) study. All detected DRFs during the OSTPRE follow-up were retrieved and based on sample size calculations 50 fractures were randomly selected for the study. 5 independent reviewers measured dislocation parameters and wrist position in a cast from the radiographs. A linear mixed model was used to estimate the concordance correlation coefficient (CCC) and total deviance index (TDI) that were used to evaluate intra- and inter-observer agreement. We used Kappa values to determine intra- and inter-rater agreement on radiographically acceptable reduction of the DRF. Limits of acceptable position were those defined by Finnish Current Care Guidelines.</p><p><strong>Results: </strong>For radial inclination, radial shortening, and dorsal/volar tilt, intra- and inter-observer correlations were high (CCC > 0.76). In addition, measurements of wrist angle in a splint had high correlations (CCC > 0.78), whereas measurement of intra-articular gap and step had poor correlations (CCC < 0.52). The Kappa value for overall agreement on the radiographically acceptable position of the DRF was modest (0.59).</p><p><strong>Conclusion: </strong>Intra- and inter-observer repeatability of casting position of radial inclination, radial shortening, and dorsal/volar tilt were high whereas intra-articular gap and step had poor correlations.</p>","PeriodicalId":6916,"journal":{"name":"Acta Orthopaedica","volume":"94 ","pages":"379-386"},"PeriodicalIF":2.5000,"publicationDate":"2023-07-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/58/fb/ActaO-94-13707.PMC10370410.pdf","citationCount":"0","resultStr":"{\"title\":\"Intra- and inter-observer agreement in distal radius fracture dislocation measurement of casting position.\",\"authors\":\"Katriina Paasikallio, Reijo Sund, Simo Miettinen, Sonja Kauranen, Hannu Sorsa, Heikki Kröger, Joonas Sirola\",\"doi\":\"10.2340/17453674.2023.13707\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background and purpose: </strong>Most displaced distal radius fractures (DRF) are treated nonoperatively, with reduction and immobilization in a cast. Studies assessing intra- or inter-observer agreement on radiologic measurements of casting position have not been published, which was the aim of our study.</p><p><strong>Patients and methods: </strong>Our study is based on the Kuopio Osteoporosis Risk Factor and Prevention (OSTPRE) study. All detected DRFs during the OSTPRE follow-up were retrieved and based on sample size calculations 50 fractures were randomly selected for the study. 5 independent reviewers measured dislocation parameters and wrist position in a cast from the radiographs. A linear mixed model was used to estimate the concordance correlation coefficient (CCC) and total deviance index (TDI) that were used to evaluate intra- and inter-observer agreement. We used Kappa values to determine intra- and inter-rater agreement on radiographically acceptable reduction of the DRF. Limits of acceptable position were those defined by Finnish Current Care Guidelines.</p><p><strong>Results: </strong>For radial inclination, radial shortening, and dorsal/volar tilt, intra- and inter-observer correlations were high (CCC > 0.76). In addition, measurements of wrist angle in a splint had high correlations (CCC > 0.78), whereas measurement of intra-articular gap and step had poor correlations (CCC < 0.52). The Kappa value for overall agreement on the radiographically acceptable position of the DRF was modest (0.59).</p><p><strong>Conclusion: </strong>Intra- and inter-observer repeatability of casting position of radial inclination, radial shortening, and dorsal/volar tilt were high whereas intra-articular gap and step had poor correlations.</p>\",\"PeriodicalId\":6916,\"journal\":{\"name\":\"Acta Orthopaedica\",\"volume\":\"94 \",\"pages\":\"379-386\"},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2023-07-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/58/fb/ActaO-94-13707.PMC10370410.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta Orthopaedica\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.2340/17453674.2023.13707\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Orthopaedica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2340/17453674.2023.13707","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
Intra- and inter-observer agreement in distal radius fracture dislocation measurement of casting position.
Background and purpose: Most displaced distal radius fractures (DRF) are treated nonoperatively, with reduction and immobilization in a cast. Studies assessing intra- or inter-observer agreement on radiologic measurements of casting position have not been published, which was the aim of our study.
Patients and methods: Our study is based on the Kuopio Osteoporosis Risk Factor and Prevention (OSTPRE) study. All detected DRFs during the OSTPRE follow-up were retrieved and based on sample size calculations 50 fractures were randomly selected for the study. 5 independent reviewers measured dislocation parameters and wrist position in a cast from the radiographs. A linear mixed model was used to estimate the concordance correlation coefficient (CCC) and total deviance index (TDI) that were used to evaluate intra- and inter-observer agreement. We used Kappa values to determine intra- and inter-rater agreement on radiographically acceptable reduction of the DRF. Limits of acceptable position were those defined by Finnish Current Care Guidelines.
Results: For radial inclination, radial shortening, and dorsal/volar tilt, intra- and inter-observer correlations were high (CCC > 0.76). In addition, measurements of wrist angle in a splint had high correlations (CCC > 0.78), whereas measurement of intra-articular gap and step had poor correlations (CCC < 0.52). The Kappa value for overall agreement on the radiographically acceptable position of the DRF was modest (0.59).
Conclusion: Intra- and inter-observer repeatability of casting position of radial inclination, radial shortening, and dorsal/volar tilt were high whereas intra-articular gap and step had poor correlations.
期刊介绍:
Acta Orthopaedica (previously Acta Orthopaedica Scandinavica) presents original articles of basic research interest, as well as clinical studies in the field of orthopedics and related sub disciplines. Ever since the journal was founded in 1930, by a group of Scandinavian orthopedic surgeons, the journal has been published for an international audience. Acta Orthopaedica is owned by the Nordic Orthopaedic Federation and is the official publication of this federation.