Kan Yan Chloe Li, Hector Dejea, Koen De Winne, Anne Bonnin, Valentino D'Onofrio, Janneke A Cox, Patricia Garcia-Canadilla, Martin Lammens, Andrew C Cook, Bart Bijnens, Amélie Dendooven
{"title":"基于同步加速器的X射线相位对比成像作为组织病理学分析的补充技术的可行性和安全性。","authors":"Kan Yan Chloe Li, Hector Dejea, Koen De Winne, Anne Bonnin, Valentino D'Onofrio, Janneke A Cox, Patricia Garcia-Canadilla, Martin Lammens, Andrew C Cook, Bart Bijnens, Amélie Dendooven","doi":"10.1007/s00418-023-02220-6","DOIUrl":null,"url":null,"abstract":"<p><p>X-ray phase contrast imaging (X-PCI) is a powerful technique for high-resolution, three-dimensional imaging of soft tissue samples in a non-destructive manner. In this technical report, we assess the quality of standard histopathological techniques performed on formalin-fixed, paraffin-embedded (FFPE) human tissue samples that have been irradiated with different doses of X-rays in the context of an X-PCI experiment. The data from this study demonstrate that routine histochemical and immunohistochemical staining quality as well as DNA and RNA analyses are not affected by previous X-PCI on human FFPE samples. From these data we conclude it is feasible and acceptable to perform X-PCI on FFPE human biopsies.</p>","PeriodicalId":13107,"journal":{"name":"Histochemistry and Cell Biology","volume":null,"pages":null},"PeriodicalIF":2.1000,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Feasibility and safety of synchrotron-based X-ray phase contrast imaging as a technique complementary to histopathology analysis.\",\"authors\":\"Kan Yan Chloe Li, Hector Dejea, Koen De Winne, Anne Bonnin, Valentino D'Onofrio, Janneke A Cox, Patricia Garcia-Canadilla, Martin Lammens, Andrew C Cook, Bart Bijnens, Amélie Dendooven\",\"doi\":\"10.1007/s00418-023-02220-6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>X-ray phase contrast imaging (X-PCI) is a powerful technique for high-resolution, three-dimensional imaging of soft tissue samples in a non-destructive manner. In this technical report, we assess the quality of standard histopathological techniques performed on formalin-fixed, paraffin-embedded (FFPE) human tissue samples that have been irradiated with different doses of X-rays in the context of an X-PCI experiment. The data from this study demonstrate that routine histochemical and immunohistochemical staining quality as well as DNA and RNA analyses are not affected by previous X-PCI on human FFPE samples. From these data we conclude it is feasible and acceptable to perform X-PCI on FFPE human biopsies.</p>\",\"PeriodicalId\":13107,\"journal\":{\"name\":\"Histochemistry and Cell Biology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2023-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Histochemistry and Cell Biology\",\"FirstCategoryId\":\"99\",\"ListUrlMain\":\"https://doi.org/10.1007/s00418-023-02220-6\",\"RegionNum\":4,\"RegionCategory\":\"生物学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/7/31 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"CELL BIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Histochemistry and Cell Biology","FirstCategoryId":"99","ListUrlMain":"https://doi.org/10.1007/s00418-023-02220-6","RegionNum":4,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/7/31 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"CELL BIOLOGY","Score":null,"Total":0}
Feasibility and safety of synchrotron-based X-ray phase contrast imaging as a technique complementary to histopathology analysis.
X-ray phase contrast imaging (X-PCI) is a powerful technique for high-resolution, three-dimensional imaging of soft tissue samples in a non-destructive manner. In this technical report, we assess the quality of standard histopathological techniques performed on formalin-fixed, paraffin-embedded (FFPE) human tissue samples that have been irradiated with different doses of X-rays in the context of an X-PCI experiment. The data from this study demonstrate that routine histochemical and immunohistochemical staining quality as well as DNA and RNA analyses are not affected by previous X-PCI on human FFPE samples. From these data we conclude it is feasible and acceptable to perform X-PCI on FFPE human biopsies.
期刊介绍:
Histochemistry and Cell Biology is devoted to the field of molecular histology and cell biology, publishing original articles dealing with the localization and identification of molecular components, metabolic activities and cell biological aspects of cells and tissues. Coverage extends to the development, application, and/or evaluation of methods and probes that can be used in the entire area of histochemistry and cell biology.