{"title":"基台类型及树脂胶合剂对种植体修复体美观的影响。","authors":"Asena Çeken, Hamiyet Kılınç, Sedanur Turgut","doi":"10.4047/jap.2023.15.3.114","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The aim of the study was to evaluate the optical properties of new generation (3Y-TZP) monolithic zirconia (MZ) with different abutment types and resin cement shades.</p><p><strong>Materials and methods: </strong>A1/LT MZ specimens were prepared (10 × 12 × 1 mm, N = 30) and divided into 3 groups according to cement shades as transparent (Tr), yellow (Y) and opaque (O). Abutment specimens were obtained from 4 different materials including zirconia (Group Z), hybrid (Group H), titanium (Group T) and anodized yellow titanium (Group AT). MZ and abutment specimens were then cemented. L<sup>*</sup>, a<sup>*</sup>, and b<sup>*</sup> parameters were obtained from MZ, MZ + abutment, and MZ + abutment + cement. ΔE<sub>001</sub><sup>*</sup> (between MZ and MZ + abutment), ΔE<sub>002</sub><sup>*</sup> (between MZ and MZ + abutment + cement) and ΔE<sub>003</sub><sup>*</sup> (between MZ + abutment and MZ + abutment + cement) values were calculated. Statistical analyses included 2-way ANOVA, Bonferroni, and Paired Sample <i>t</i>-Tests (<i>P</i> < .05).</p><p><strong>Results: </strong>Abutment types and resin cements had significant effect on L<sup>*</sup>, a<sup>*</sup>, b<sup>*</sup>, ΔE<sub>001</sub><sup>*</sup>, ΔE<sub>002</sub><sup>*</sup>, and ΔE<sub>003</sub><sup>*</sup> values (<i>P</i> < .001). Without cementation, whereas zirconia abutment resulted in the least discoloration (ΔE<sub>001</sub><sup>*</sup> = 0.68), titanium abutment caused the most discoloration (ΔE<sub>001</sub><sup>*</sup> = 4.99). The least ΔE<sub>002</sub><sup>*</sup> = 0.68 value was seen using zirconia abutment after cementation with yellow shaded cement. Opaque shaded cement caused the most color change (ΔE<sub>003</sub><sup>*</sup> = 5.24). Cement application increased the L<sup>*</sup> values in all groups.</p><p><strong>Conclusion: </strong>The least color change with/without cement was observed in crown configurations created with zirconia abutments. Zirconia and hybrid abutments produced significantly lower ΔE<sub>002</sub><sup>*</sup> and ΔE<sub>003</sub><sup>*</sup> values in combination with yellow shaded cement. The usage of opaque shaded cement in titanium/anodized titanium groups may enable the clinically unacceptable ΔE<sub>00</sub><sup>*</sup> value to reach the acceptable level.</p>","PeriodicalId":51291,"journal":{"name":"Journal of Advanced Prosthodontics","volume":"15 3","pages":"114-125"},"PeriodicalIF":2.7000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/1e/0c/jap-15-114.PMC10333101.pdf","citationCount":"0","resultStr":"{\"title\":\"Effect of abutment types and resin cements on the esthetics of implant-supported restorations.\",\"authors\":\"Asena Çeken, Hamiyet Kılınç, Sedanur Turgut\",\"doi\":\"10.4047/jap.2023.15.3.114\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The aim of the study was to evaluate the optical properties of new generation (3Y-TZP) monolithic zirconia (MZ) with different abutment types and resin cement shades.</p><p><strong>Materials and methods: </strong>A1/LT MZ specimens were prepared (10 × 12 × 1 mm, N = 30) and divided into 3 groups according to cement shades as transparent (Tr), yellow (Y) and opaque (O). Abutment specimens were obtained from 4 different materials including zirconia (Group Z), hybrid (Group H), titanium (Group T) and anodized yellow titanium (Group AT). MZ and abutment specimens were then cemented. L<sup>*</sup>, a<sup>*</sup>, and b<sup>*</sup> parameters were obtained from MZ, MZ + abutment, and MZ + abutment + cement. ΔE<sub>001</sub><sup>*</sup> (between MZ and MZ + abutment), ΔE<sub>002</sub><sup>*</sup> (between MZ and MZ + abutment + cement) and ΔE<sub>003</sub><sup>*</sup> (between MZ + abutment and MZ + abutment + cement) values were calculated. Statistical analyses included 2-way ANOVA, Bonferroni, and Paired Sample <i>t</i>-Tests (<i>P</i> < .05).</p><p><strong>Results: </strong>Abutment types and resin cements had significant effect on L<sup>*</sup>, a<sup>*</sup>, b<sup>*</sup>, ΔE<sub>001</sub><sup>*</sup>, ΔE<sub>002</sub><sup>*</sup>, and ΔE<sub>003</sub><sup>*</sup> values (<i>P</i> < .001). Without cementation, whereas zirconia abutment resulted in the least discoloration (ΔE<sub>001</sub><sup>*</sup> = 0.68), titanium abutment caused the most discoloration (ΔE<sub>001</sub><sup>*</sup> = 4.99). The least ΔE<sub>002</sub><sup>*</sup> = 0.68 value was seen using zirconia abutment after cementation with yellow shaded cement. Opaque shaded cement caused the most color change (ΔE<sub>003</sub><sup>*</sup> = 5.24). Cement application increased the L<sup>*</sup> values in all groups.</p><p><strong>Conclusion: </strong>The least color change with/without cement was observed in crown configurations created with zirconia abutments. Zirconia and hybrid abutments produced significantly lower ΔE<sub>002</sub><sup>*</sup> and ΔE<sub>003</sub><sup>*</sup> values in combination with yellow shaded cement. The usage of opaque shaded cement in titanium/anodized titanium groups may enable the clinically unacceptable ΔE<sub>00</sub><sup>*</sup> value to reach the acceptable level.</p>\",\"PeriodicalId\":51291,\"journal\":{\"name\":\"Journal of Advanced Prosthodontics\",\"volume\":\"15 3\",\"pages\":\"114-125\"},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2023-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/1e/0c/jap-15-114.PMC10333101.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Advanced Prosthodontics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.4047/jap.2023.15.3.114\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Advanced Prosthodontics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4047/jap.2023.15.3.114","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
Effect of abutment types and resin cements on the esthetics of implant-supported restorations.
Purpose: The aim of the study was to evaluate the optical properties of new generation (3Y-TZP) monolithic zirconia (MZ) with different abutment types and resin cement shades.
Materials and methods: A1/LT MZ specimens were prepared (10 × 12 × 1 mm, N = 30) and divided into 3 groups according to cement shades as transparent (Tr), yellow (Y) and opaque (O). Abutment specimens were obtained from 4 different materials including zirconia (Group Z), hybrid (Group H), titanium (Group T) and anodized yellow titanium (Group AT). MZ and abutment specimens were then cemented. L*, a*, and b* parameters were obtained from MZ, MZ + abutment, and MZ + abutment + cement. ΔE001* (between MZ and MZ + abutment), ΔE002* (between MZ and MZ + abutment + cement) and ΔE003* (between MZ + abutment and MZ + abutment + cement) values were calculated. Statistical analyses included 2-way ANOVA, Bonferroni, and Paired Sample t-Tests (P < .05).
Results: Abutment types and resin cements had significant effect on L*, a*, b*, ΔE001*, ΔE002*, and ΔE003* values (P < .001). Without cementation, whereas zirconia abutment resulted in the least discoloration (ΔE001* = 0.68), titanium abutment caused the most discoloration (ΔE001* = 4.99). The least ΔE002* = 0.68 value was seen using zirconia abutment after cementation with yellow shaded cement. Opaque shaded cement caused the most color change (ΔE003* = 5.24). Cement application increased the L* values in all groups.
Conclusion: The least color change with/without cement was observed in crown configurations created with zirconia abutments. Zirconia and hybrid abutments produced significantly lower ΔE002* and ΔE003* values in combination with yellow shaded cement. The usage of opaque shaded cement in titanium/anodized titanium groups may enable the clinically unacceptable ΔE00* value to reach the acceptable level.
期刊介绍:
This journal aims to convey scientific and clinical progress in the field of prosthodontics and its related areas to many dental communities concerned with esthetic and functional restorations, occlusion, implants, prostheses, and biomaterials related to prosthodontics.
This journal publishes
• Original research data of high scientific merit in the field of diagnosis, function, esthetics and stomatognathic physiology related to prosthodontic rehabilitation, physiology and mechanics of occlusion, mechanical and biologic aspects of prosthodontic materials including dental implants.
• Review articles by experts on controversies and new developments in prosthodontics.
• Case reports if they provide or document new fundamental knowledge.