不同金属桩、水泥和暴露参数对锥束计算机断层伪影的影响。

IF 1.7 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
Ana Priscila Lira de Farias Freitas, Larissa Rangel Peixoto, Fernanda Clotilde Mariz Suassuna, Patrícia Meira Bento, Ana Marly Araújo Maia Amorim, Karla Rovaris Silva, Renata Quirino de Almeida Barros, Andrea Dos Anjos Pontual de Andrade Lima, Daniela Pita de Melo
{"title":"不同金属桩、水泥和暴露参数对锥束计算机断层伪影的影响。","authors":"Ana Priscila Lira de Farias Freitas,&nbsp;Larissa Rangel Peixoto,&nbsp;Fernanda Clotilde Mariz Suassuna,&nbsp;Patrícia Meira Bento,&nbsp;Ana Marly Araújo Maia Amorim,&nbsp;Karla Rovaris Silva,&nbsp;Renata Quirino de Almeida Barros,&nbsp;Andrea Dos Anjos Pontual de Andrade Lima,&nbsp;Daniela Pita de Melo","doi":"10.5624/isd.20220185","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study assessed the intensity of artifacts produced by 2 metal posts, 2 cements, and different exposure parameters using 2 cone-beam computed tomography (CBCT) units.</p><p><strong>Materials and methods: </strong>The sample was composed of 20 single-rooted premolars, divided into 4 groups: Ni-Cr/zinc phosphate, Ni-Cr/resin cement, Ag-Pd/zinc phosphate, and Ag-Pd/resin cement. Samples were scanned before and after post insertion and cementation using a CS9000 3D scanner with 4 exposure parameters (85/90 kV and 6.3/10 mA) and an i-CAT scanner with 120 kV and 5 mA. The presence of artifacts was assessed subjectively by 2 observers and objectively by a trained observer using ImageJ software. The Mann-Whitney, Wilcoxon, weighted kappa, and chi-square tests were used to assess data at a 95% confidence level (α<0.05).</p><p><strong>Results: </strong>In the subjective analyses, AgPd presented more hypodense and hyperdense lines than NiCr (<i>P</i><0.05), and more hypodense halos were found using i-CAT (<i>P</i><0.05) than using CS9000 3D. More hypodense halos, hypodense lines, and hyperdense lines were observed at 10 mA than at 6.3 mA (<i>P</i><0.05). More hypodense halos were observed at 85 kV than at 90 kV (<i>P</i><0.05). CS9000 3D presented more hypodense and hyperdense lines than i-CAT (<i>P</i><0.05). In the objective analyses, AgPd presented higher percentages of hyperdense and hypodense artifacts than NiCr (<i>P</i><0.05). Zinc phosphate cement presented higher hyperdense artifact percentages on CS9000 3D scans (<i>P</i><0.05). CS9000 3D presented higher artifact percentages than i-CAT (<i>P</i><0.05).</p><p><strong>Conclusion: </strong>High-atomic-number alloys, higher tube current, and lower tube voltage may increase the artifacts present in CBCT images.</p>","PeriodicalId":51714,"journal":{"name":"Imaging Science in Dentistry","volume":"53 2","pages":"127-135"},"PeriodicalIF":1.7000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/d6/b0/isd-53-127.PMC10315228.pdf","citationCount":"0","resultStr":"{\"title\":\"The effects of different metal posts, cements, and exposure parameters on cone-beam computed tomography artifacts.\",\"authors\":\"Ana Priscila Lira de Farias Freitas,&nbsp;Larissa Rangel Peixoto,&nbsp;Fernanda Clotilde Mariz Suassuna,&nbsp;Patrícia Meira Bento,&nbsp;Ana Marly Araújo Maia Amorim,&nbsp;Karla Rovaris Silva,&nbsp;Renata Quirino de Almeida Barros,&nbsp;Andrea Dos Anjos Pontual de Andrade Lima,&nbsp;Daniela Pita de Melo\",\"doi\":\"10.5624/isd.20220185\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>This study assessed the intensity of artifacts produced by 2 metal posts, 2 cements, and different exposure parameters using 2 cone-beam computed tomography (CBCT) units.</p><p><strong>Materials and methods: </strong>The sample was composed of 20 single-rooted premolars, divided into 4 groups: Ni-Cr/zinc phosphate, Ni-Cr/resin cement, Ag-Pd/zinc phosphate, and Ag-Pd/resin cement. Samples were scanned before and after post insertion and cementation using a CS9000 3D scanner with 4 exposure parameters (85/90 kV and 6.3/10 mA) and an i-CAT scanner with 120 kV and 5 mA. The presence of artifacts was assessed subjectively by 2 observers and objectively by a trained observer using ImageJ software. The Mann-Whitney, Wilcoxon, weighted kappa, and chi-square tests were used to assess data at a 95% confidence level (α<0.05).</p><p><strong>Results: </strong>In the subjective analyses, AgPd presented more hypodense and hyperdense lines than NiCr (<i>P</i><0.05), and more hypodense halos were found using i-CAT (<i>P</i><0.05) than using CS9000 3D. More hypodense halos, hypodense lines, and hyperdense lines were observed at 10 mA than at 6.3 mA (<i>P</i><0.05). More hypodense halos were observed at 85 kV than at 90 kV (<i>P</i><0.05). CS9000 3D presented more hypodense and hyperdense lines than i-CAT (<i>P</i><0.05). In the objective analyses, AgPd presented higher percentages of hyperdense and hypodense artifacts than NiCr (<i>P</i><0.05). Zinc phosphate cement presented higher hyperdense artifact percentages on CS9000 3D scans (<i>P</i><0.05). CS9000 3D presented higher artifact percentages than i-CAT (<i>P</i><0.05).</p><p><strong>Conclusion: </strong>High-atomic-number alloys, higher tube current, and lower tube voltage may increase the artifacts present in CBCT images.</p>\",\"PeriodicalId\":51714,\"journal\":{\"name\":\"Imaging Science in Dentistry\",\"volume\":\"53 2\",\"pages\":\"127-135\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2023-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/d6/b0/isd-53-127.PMC10315228.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Imaging Science in Dentistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5624/isd.20220185\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Imaging Science in Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5624/isd.20220185","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究利用2台锥形束计算机断层扫描(CBCT)设备评估了2根金属桩、2种水泥和不同暴露参数所产生的假影强度。材料与方法:样品由20颗单根前磨牙组成,分为4组:Ni-Cr/磷酸锌、Ni-Cr/树脂水泥、Ag-Pd/磷酸锌、Ag-Pd/树脂水泥。在插入和胶合前后,使用具有4个曝光参数(85/90 kV和6.3/10 mA)的CS9000 3D扫描仪和120 kV和5 mA的i-CAT扫描仪对样品进行扫描。人工制品的存在由2名观察者主观地评估,客观地由训练有素的观察者使用ImageJ软件评估。采用Mann-Whitney、Wilcoxon、加权kappa和卡方检验对数据进行95%置信水平的评估(α)结果:在主观分析中,AgPd比NiCr (ppppppppppp)呈现出更多的低密度和高密度线。结论:高原子序数合金、高管电流和低管电压可能会增加CBCT图像中的伪像。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

The effects of different metal posts, cements, and exposure parameters on cone-beam computed tomography artifacts.

The effects of different metal posts, cements, and exposure parameters on cone-beam computed tomography artifacts.

The effects of different metal posts, cements, and exposure parameters on cone-beam computed tomography artifacts.

The effects of different metal posts, cements, and exposure parameters on cone-beam computed tomography artifacts.

Purpose: This study assessed the intensity of artifacts produced by 2 metal posts, 2 cements, and different exposure parameters using 2 cone-beam computed tomography (CBCT) units.

Materials and methods: The sample was composed of 20 single-rooted premolars, divided into 4 groups: Ni-Cr/zinc phosphate, Ni-Cr/resin cement, Ag-Pd/zinc phosphate, and Ag-Pd/resin cement. Samples were scanned before and after post insertion and cementation using a CS9000 3D scanner with 4 exposure parameters (85/90 kV and 6.3/10 mA) and an i-CAT scanner with 120 kV and 5 mA. The presence of artifacts was assessed subjectively by 2 observers and objectively by a trained observer using ImageJ software. The Mann-Whitney, Wilcoxon, weighted kappa, and chi-square tests were used to assess data at a 95% confidence level (α<0.05).

Results: In the subjective analyses, AgPd presented more hypodense and hyperdense lines than NiCr (P<0.05), and more hypodense halos were found using i-CAT (P<0.05) than using CS9000 3D. More hypodense halos, hypodense lines, and hyperdense lines were observed at 10 mA than at 6.3 mA (P<0.05). More hypodense halos were observed at 85 kV than at 90 kV (P<0.05). CS9000 3D presented more hypodense and hyperdense lines than i-CAT (P<0.05). In the objective analyses, AgPd presented higher percentages of hyperdense and hypodense artifacts than NiCr (P<0.05). Zinc phosphate cement presented higher hyperdense artifact percentages on CS9000 3D scans (P<0.05). CS9000 3D presented higher artifact percentages than i-CAT (P<0.05).

Conclusion: High-atomic-number alloys, higher tube current, and lower tube voltage may increase the artifacts present in CBCT images.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Imaging Science in Dentistry
Imaging Science in Dentistry DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
2.90
自引率
11.10%
发文量
42
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信