Accura球囊扩张导管在成人经皮球囊肺瓣膜成形术中的应用。

IF 1.3
Najeeb Ullah Sofi, Mohit Sachan, Santosh K Sinha, Mukesh J Jha, Umeshwar Pandey, Mahmodullah Razi, Awadhesh K Sharma, Praveen Shukla, Puneet Aggarwal, Kumar Himanshu, Prachi Sharma, Ramesh Thakur
{"title":"Accura球囊扩张导管在成人经皮球囊肺瓣膜成形术中的应用。","authors":"Najeeb Ullah Sofi,&nbsp;Mohit Sachan,&nbsp;Santosh K Sinha,&nbsp;Mukesh J Jha,&nbsp;Umeshwar Pandey,&nbsp;Mahmodullah Razi,&nbsp;Awadhesh K Sharma,&nbsp;Praveen Shukla,&nbsp;Puneet Aggarwal,&nbsp;Kumar Himanshu,&nbsp;Prachi Sharma,&nbsp;Ramesh Thakur","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Percutaneous balloon pulmonary valvuloplasty (PBPV) is the treatment of choice for hemodynamically significant pulmonary stenosis (PS). Currently, the Tyshak balloon is preferred but requires multiple dilatations because of its instability across the valve leading to a watermelon seeding effect. Accura balloon (Vascular Concept, UK) offers an advantage in its self-positioning configuration, variable diameter, and rapid inflation-deflation sequence which shortens the procedural time and valve injury.</p><p><strong>Method: </strong>43 patients with severe pulmonary valve stenosis underwent PBPV using an Accura balloon at LPS Institute of Cardiology, GSVM Medical College, Kanpur, UP, India from March 2018 to February 2022. The procedure was carried out using the standard technique but the metallic straightener was removed when the catheter reached the right atrium to facilitate its delivery across the pulmonary valve. Patients were followed up by 2D echo at 24 hours and 6 months.</p><p><strong>Result: </strong>Successful BPV was done in all 43 patients [with mean age 21.9 (range 18-41); 31 males and 12 females] among which 5 patients had dysplastic valves. The mean diameter of the annulus was 18.5 (range 15-21) mm. Immediate hemodynamic improvement was observed in 38 patients (88%) as peak systolic gradient reduced from 84±13 to 22±12 mmHg (P<0.005) while 5 patients (12%) had <50% reduction of resting gradient, though it came down significantly at 6 months. Fluoroscopy and procedural time were 5.2±1.9 min and 22.6±3.4 min respectively. Major complications (death, cardiac perforation, tamponade, tricuspid regurgitation, requirement of blood transfusion) were none. Minor complications (transient hypotension, ventricular premature contraction, transient bradycardia) were reported in all patients. Accura balloon being bulky were delivered over left atrial and super stiff Amplatz wire in 36 and 7 patients respectively.</p><p><strong>Conclusion: </strong>PBPV using Accura balloon is safe and effective for both stenosed and dysplastic valves. In a few patients, maximal effect will be observed over a period of 6 months.</p>","PeriodicalId":7427,"journal":{"name":"American journal of cardiovascular disease","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10352819/pdf/ajcd0013-0152.pdf","citationCount":"0","resultStr":"{\"title\":\"Accura balloon dilatation catheter for percutaneous balloon pulmonary valvuloplasty among adult patients-its protean use.\",\"authors\":\"Najeeb Ullah Sofi,&nbsp;Mohit Sachan,&nbsp;Santosh K Sinha,&nbsp;Mukesh J Jha,&nbsp;Umeshwar Pandey,&nbsp;Mahmodullah Razi,&nbsp;Awadhesh K Sharma,&nbsp;Praveen Shukla,&nbsp;Puneet Aggarwal,&nbsp;Kumar Himanshu,&nbsp;Prachi Sharma,&nbsp;Ramesh Thakur\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Percutaneous balloon pulmonary valvuloplasty (PBPV) is the treatment of choice for hemodynamically significant pulmonary stenosis (PS). Currently, the Tyshak balloon is preferred but requires multiple dilatations because of its instability across the valve leading to a watermelon seeding effect. Accura balloon (Vascular Concept, UK) offers an advantage in its self-positioning configuration, variable diameter, and rapid inflation-deflation sequence which shortens the procedural time and valve injury.</p><p><strong>Method: </strong>43 patients with severe pulmonary valve stenosis underwent PBPV using an Accura balloon at LPS Institute of Cardiology, GSVM Medical College, Kanpur, UP, India from March 2018 to February 2022. The procedure was carried out using the standard technique but the metallic straightener was removed when the catheter reached the right atrium to facilitate its delivery across the pulmonary valve. Patients were followed up by 2D echo at 24 hours and 6 months.</p><p><strong>Result: </strong>Successful BPV was done in all 43 patients [with mean age 21.9 (range 18-41); 31 males and 12 females] among which 5 patients had dysplastic valves. The mean diameter of the annulus was 18.5 (range 15-21) mm. Immediate hemodynamic improvement was observed in 38 patients (88%) as peak systolic gradient reduced from 84±13 to 22±12 mmHg (P<0.005) while 5 patients (12%) had <50% reduction of resting gradient, though it came down significantly at 6 months. Fluoroscopy and procedural time were 5.2±1.9 min and 22.6±3.4 min respectively. Major complications (death, cardiac perforation, tamponade, tricuspid regurgitation, requirement of blood transfusion) were none. Minor complications (transient hypotension, ventricular premature contraction, transient bradycardia) were reported in all patients. Accura balloon being bulky were delivered over left atrial and super stiff Amplatz wire in 36 and 7 patients respectively.</p><p><strong>Conclusion: </strong>PBPV using Accura balloon is safe and effective for both stenosed and dysplastic valves. In a few patients, maximal effect will be observed over a period of 6 months.</p>\",\"PeriodicalId\":7427,\"journal\":{\"name\":\"American journal of cardiovascular disease\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10352819/pdf/ajcd0013-0152.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"American journal of cardiovascular disease\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of cardiovascular disease","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景:经皮球囊肺动脉瓣成形术(PBPV)是血流动力学显著性肺动脉狭窄(PS)的首选治疗方法。目前,Tyshak气球是首选,但需要多次膨胀,因为它在阀门上不稳定,导致西瓜播种效应。Accura球囊(Vascular Concept, UK)的优势在于其自定位结构、可变直径和快速充气-放气顺序,缩短了操作时间和阀门损伤。方法:2018年3月至2022年2月,在印度北方邦坎普尔GSVM医学院LPS心脏病研究所,43例严重肺动脉瓣狭窄患者采用Accura球囊行PBPV。手术采用标准技术进行,但当导管到达右心房时,金属矫直器被移除,以方便其通过肺动脉瓣输送。分别于24小时和6个月行二维超声随访。结果:43例患者均成功行BPV手术[平均年龄21.9岁(18-41岁);男31例,女12例],其中瓣膜发育不良5例。环的平均直径为18.5(范围15-21)mm。38例(88%)患者的血流动力学立即得到改善,峰值收缩梯度从84±13降低到22±12 mmHg(结论:使用Accura球囊的PBPV治疗狭窄和发育不良的瓣膜是安全有效的。在少数患者中,最大效果将在6个月的时间内观察到。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Accura balloon dilatation catheter for percutaneous balloon pulmonary valvuloplasty among adult patients-its protean use.

Background: Percutaneous balloon pulmonary valvuloplasty (PBPV) is the treatment of choice for hemodynamically significant pulmonary stenosis (PS). Currently, the Tyshak balloon is preferred but requires multiple dilatations because of its instability across the valve leading to a watermelon seeding effect. Accura balloon (Vascular Concept, UK) offers an advantage in its self-positioning configuration, variable diameter, and rapid inflation-deflation sequence which shortens the procedural time and valve injury.

Method: 43 patients with severe pulmonary valve stenosis underwent PBPV using an Accura balloon at LPS Institute of Cardiology, GSVM Medical College, Kanpur, UP, India from March 2018 to February 2022. The procedure was carried out using the standard technique but the metallic straightener was removed when the catheter reached the right atrium to facilitate its delivery across the pulmonary valve. Patients were followed up by 2D echo at 24 hours and 6 months.

Result: Successful BPV was done in all 43 patients [with mean age 21.9 (range 18-41); 31 males and 12 females] among which 5 patients had dysplastic valves. The mean diameter of the annulus was 18.5 (range 15-21) mm. Immediate hemodynamic improvement was observed in 38 patients (88%) as peak systolic gradient reduced from 84±13 to 22±12 mmHg (P<0.005) while 5 patients (12%) had <50% reduction of resting gradient, though it came down significantly at 6 months. Fluoroscopy and procedural time were 5.2±1.9 min and 22.6±3.4 min respectively. Major complications (death, cardiac perforation, tamponade, tricuspid regurgitation, requirement of blood transfusion) were none. Minor complications (transient hypotension, ventricular premature contraction, transient bradycardia) were reported in all patients. Accura balloon being bulky were delivered over left atrial and super stiff Amplatz wire in 36 and 7 patients respectively.

Conclusion: PBPV using Accura balloon is safe and effective for both stenosed and dysplastic valves. In a few patients, maximal effect will be observed over a period of 6 months.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
American journal of cardiovascular disease
American journal of cardiovascular disease CARDIAC & CARDIOVASCULAR SYSTEMS-
自引率
0.00%
发文量
21
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信