Halime Serinçay, Hayrullah Uğur Güler, Kezban Ulubayram, Naşide Mangır
{"title":"组织间置皮瓣在膀胱阴道瘘修复中的应用综述。","authors":"Halime Serinçay, Hayrullah Uğur Güler, Kezban Ulubayram, Naşide Mangır","doi":"10.1177/17562872231182217","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Research on the use of tissue interposition flaps (TIFs) in vesicovaginal fistulae (VVF) repair is a broad area where a very wide range of natural and synthetic materials have been used. The occurrence of VVF is also diverse in the social and clinical settings, resulting in a parallel heterogeneity in the published literature on its treatment. The use of synthetic and autologous TIFs in VVF repair is not yet standardized with a lack of the most efficacious type and technique of the TIF.</p><p><strong>Objectives: </strong>The aim of this study was to systematically review all synthetic and autologous TIFs used in the surgical repair of VVFs.</p><p><strong>Data sources and methods: </strong>In this scoping review, the surgical outcomes of autologous and synthetic interposition flaps used in VVF treatment meeting the inclusion criteria were determined. We searched the literature using Ovid MEDLINE and PubMed databases between 1974 and 2022. Study characteristics were recorded, and data on the change in fistulae size and location, surgical approach, success rate, preoperative patient evaluation and outcome evaluation were extracted from each study independently by two authors.</p><p><strong>Results: </strong>A total of 25 articles that met the inclusion criteria were included in the final analysis. A total of 943 and 127 patients who had received autologous and synthetic flaps, respectively, were included in this scoping review. The fistulae characteristics were highly variable with regard to their size, complexity, aetiology, location and radiation. Outcome assessments of fistulae repair in included studies were mostly based on symptom evaluation. Physical examination, cystogram and methylene blue test were the methods in order of preference. Postoperative complications, such as infection, bleeding, donor site, pain, voiding dysfunction and other complications, were reported in patients after fistulae repair in all included studies.</p><p><strong>Conclusion: </strong>The use of TIFs in VVF repair was common especially in complex and large fistulae. Autologous TIFs appear to be the standard of care at the moment, and synthetic TIFs were investigated in prospective clinical trials in a limited number of selected cases. Evidence levels of clinical studies evaluating the effectiveness of interposition flaps were overall low.</p>","PeriodicalId":23010,"journal":{"name":"Therapeutic Advances in Urology","volume":null,"pages":null},"PeriodicalIF":2.6000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/3d/ef/10.1177_17562872231182217.PMC10331086.pdf","citationCount":"0","resultStr":"{\"title\":\"A scoping review of tissue interposition flaps used in vesicovaginal fistulae repair.\",\"authors\":\"Halime Serinçay, Hayrullah Uğur Güler, Kezban Ulubayram, Naşide Mangır\",\"doi\":\"10.1177/17562872231182217\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Research on the use of tissue interposition flaps (TIFs) in vesicovaginal fistulae (VVF) repair is a broad area where a very wide range of natural and synthetic materials have been used. The occurrence of VVF is also diverse in the social and clinical settings, resulting in a parallel heterogeneity in the published literature on its treatment. The use of synthetic and autologous TIFs in VVF repair is not yet standardized with a lack of the most efficacious type and technique of the TIF.</p><p><strong>Objectives: </strong>The aim of this study was to systematically review all synthetic and autologous TIFs used in the surgical repair of VVFs.</p><p><strong>Data sources and methods: </strong>In this scoping review, the surgical outcomes of autologous and synthetic interposition flaps used in VVF treatment meeting the inclusion criteria were determined. We searched the literature using Ovid MEDLINE and PubMed databases between 1974 and 2022. Study characteristics were recorded, and data on the change in fistulae size and location, surgical approach, success rate, preoperative patient evaluation and outcome evaluation were extracted from each study independently by two authors.</p><p><strong>Results: </strong>A total of 25 articles that met the inclusion criteria were included in the final analysis. A total of 943 and 127 patients who had received autologous and synthetic flaps, respectively, were included in this scoping review. The fistulae characteristics were highly variable with regard to their size, complexity, aetiology, location and radiation. Outcome assessments of fistulae repair in included studies were mostly based on symptom evaluation. Physical examination, cystogram and methylene blue test were the methods in order of preference. Postoperative complications, such as infection, bleeding, donor site, pain, voiding dysfunction and other complications, were reported in patients after fistulae repair in all included studies.</p><p><strong>Conclusion: </strong>The use of TIFs in VVF repair was common especially in complex and large fistulae. Autologous TIFs appear to be the standard of care at the moment, and synthetic TIFs were investigated in prospective clinical trials in a limited number of selected cases. Evidence levels of clinical studies evaluating the effectiveness of interposition flaps were overall low.</p>\",\"PeriodicalId\":23010,\"journal\":{\"name\":\"Therapeutic Advances in Urology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/3d/ef/10.1177_17562872231182217.PMC10331086.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Therapeutic Advances in Urology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/17562872231182217\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"UROLOGY & NEPHROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Therapeutic Advances in Urology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/17562872231182217","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
A scoping review of tissue interposition flaps used in vesicovaginal fistulae repair.
Background: Research on the use of tissue interposition flaps (TIFs) in vesicovaginal fistulae (VVF) repair is a broad area where a very wide range of natural and synthetic materials have been used. The occurrence of VVF is also diverse in the social and clinical settings, resulting in a parallel heterogeneity in the published literature on its treatment. The use of synthetic and autologous TIFs in VVF repair is not yet standardized with a lack of the most efficacious type and technique of the TIF.
Objectives: The aim of this study was to systematically review all synthetic and autologous TIFs used in the surgical repair of VVFs.
Data sources and methods: In this scoping review, the surgical outcomes of autologous and synthetic interposition flaps used in VVF treatment meeting the inclusion criteria were determined. We searched the literature using Ovid MEDLINE and PubMed databases between 1974 and 2022. Study characteristics were recorded, and data on the change in fistulae size and location, surgical approach, success rate, preoperative patient evaluation and outcome evaluation were extracted from each study independently by two authors.
Results: A total of 25 articles that met the inclusion criteria were included in the final analysis. A total of 943 and 127 patients who had received autologous and synthetic flaps, respectively, were included in this scoping review. The fistulae characteristics were highly variable with regard to their size, complexity, aetiology, location and radiation. Outcome assessments of fistulae repair in included studies were mostly based on symptom evaluation. Physical examination, cystogram and methylene blue test were the methods in order of preference. Postoperative complications, such as infection, bleeding, donor site, pain, voiding dysfunction and other complications, were reported in patients after fistulae repair in all included studies.
Conclusion: The use of TIFs in VVF repair was common especially in complex and large fistulae. Autologous TIFs appear to be the standard of care at the moment, and synthetic TIFs were investigated in prospective clinical trials in a limited number of selected cases. Evidence levels of clinical studies evaluating the effectiveness of interposition flaps were overall low.
期刊介绍:
Therapeutic Advances in Urology delivers the highest quality peer-reviewed articles, reviews, and scholarly comment on pioneering efforts and innovative studies across all areas of urology.
The journal has a strong clinical and pharmacological focus and is aimed at clinicians and researchers in urology, providing a forum in print and online for publishing the highest quality articles in this area. The editors welcome articles of current interest across all areas of urology, including treatment of urological disorders, with a focus on emerging pharmacological therapies.