透视引导下从两只猫的椎管中取出微芯片的手术。

IF 1.5 4区 农林科学 Q2 VETERINARY SCIENCES
Justin Mergl, Laura Nutt, Augusto Pareja
{"title":"透视引导下从两只猫的椎管中取出微芯片的手术。","authors":"Justin Mergl,&nbsp;Laura Nutt,&nbsp;Augusto Pareja","doi":"10.5326/JAAHA-MS-7356","DOIUrl":null,"url":null,"abstract":"<p><p>Two cats were presented with acute left-sided paresis after implantation of a microchip at the referring veterinary clinic. Neurological examinations were consistent with left-sided lesions between spinal cord segments C1 and C5. Orthogonal radiographs of the cervical spine showed a microchip dorsoventrally oriented, partially embedded in the cervical vertebral canal. Fluoroscopy was used to localize and retrieve the foreign body from the cervical spinal cord in each case. Improvement in clinical condition and return to ambulation was observed in both cats within 48 hr of surgical removal of the implant. No significant perioperative adverse events were noted during the surgical retrieval of the microchip. Two previously reported cases of intraspinal canal microchip placement had been treated surgically by hemilaminectomy. This approach carries a risk of complications, including hemorrhage from the venous sinus, iatrogenic damage to the spinal cord, and improper identification of the surgical site, requires advanced surgical training, and typically has an extended surgical time. The use of fluoroscopy to assist intraoperative localization of a spinal canal foreign body may lessen the requirement for more invasive surgical procedures.</p>","PeriodicalId":17185,"journal":{"name":"Journal of the American Animal Hospital Association","volume":"59 4","pages":"193-197"},"PeriodicalIF":1.5000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Fluoroscopy-Guided Surgical Removal of a Microchip from the Spinal Canal of Two Cats.\",\"authors\":\"Justin Mergl,&nbsp;Laura Nutt,&nbsp;Augusto Pareja\",\"doi\":\"10.5326/JAAHA-MS-7356\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Two cats were presented with acute left-sided paresis after implantation of a microchip at the referring veterinary clinic. Neurological examinations were consistent with left-sided lesions between spinal cord segments C1 and C5. Orthogonal radiographs of the cervical spine showed a microchip dorsoventrally oriented, partially embedded in the cervical vertebral canal. Fluoroscopy was used to localize and retrieve the foreign body from the cervical spinal cord in each case. Improvement in clinical condition and return to ambulation was observed in both cats within 48 hr of surgical removal of the implant. No significant perioperative adverse events were noted during the surgical retrieval of the microchip. Two previously reported cases of intraspinal canal microchip placement had been treated surgically by hemilaminectomy. This approach carries a risk of complications, including hemorrhage from the venous sinus, iatrogenic damage to the spinal cord, and improper identification of the surgical site, requires advanced surgical training, and typically has an extended surgical time. The use of fluoroscopy to assist intraoperative localization of a spinal canal foreign body may lessen the requirement for more invasive surgical procedures.</p>\",\"PeriodicalId\":17185,\"journal\":{\"name\":\"Journal of the American Animal Hospital Association\",\"volume\":\"59 4\",\"pages\":\"193-197\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2023-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the American Animal Hospital Association\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://doi.org/10.5326/JAAHA-MS-7356\",\"RegionNum\":4,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"VETERINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the American Animal Hospital Association","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.5326/JAAHA-MS-7356","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

在转诊兽医诊所植入微芯片后,两只猫出现了急性左脑麻痹。神经学检查与左侧脊髓节段C1和C5之间的病变一致。颈椎的正交x线片显示微芯片背侧定向,部分嵌入颈椎椎管。在每个病例中,都使用了透视来定位和取出颈脊髓中的异物。在手术移除植入物后48小时内,观察到两只猫的临床状况改善并恢复行走。在手术取出微芯片期间,未发现明显的围手术期不良事件。先前报道的两例椎管内植入微芯片的病例已通过半椎板切除术进行手术治疗。这种方法有并发症的风险,包括静脉窦出血、医源性脊髓损伤和手术部位的不正确识别,需要高级外科培训,通常需要延长手术时间。使用透视技术协助术中定位椎管异物可以减少对更具侵入性的外科手术的需求。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Fluoroscopy-Guided Surgical Removal of a Microchip from the Spinal Canal of Two Cats.

Two cats were presented with acute left-sided paresis after implantation of a microchip at the referring veterinary clinic. Neurological examinations were consistent with left-sided lesions between spinal cord segments C1 and C5. Orthogonal radiographs of the cervical spine showed a microchip dorsoventrally oriented, partially embedded in the cervical vertebral canal. Fluoroscopy was used to localize and retrieve the foreign body from the cervical spinal cord in each case. Improvement in clinical condition and return to ambulation was observed in both cats within 48 hr of surgical removal of the implant. No significant perioperative adverse events were noted during the surgical retrieval of the microchip. Two previously reported cases of intraspinal canal microchip placement had been treated surgically by hemilaminectomy. This approach carries a risk of complications, including hemorrhage from the venous sinus, iatrogenic damage to the spinal cord, and improper identification of the surgical site, requires advanced surgical training, and typically has an extended surgical time. The use of fluoroscopy to assist intraoperative localization of a spinal canal foreign body may lessen the requirement for more invasive surgical procedures.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.70
自引率
0.00%
发文量
57
审稿时长
18-36 weeks
期刊介绍: The purpose of the JAAHA is to publish relevant, original, timely scientific and technical information pertaining to the practice of small animal medicine and surgery.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信