化学灭菌和高压灭菌前后复合树脂(双色度)色度指南与Vita陶瓷色度的比较。

Shekhar Gupta, Mohammed E Sayed, Bharti Gupta, Aditya Patel, Khurshid Mattoo, Noura Turki Alotaibi, Salha I Alnemi, Hossam F Jokhadar, Boshra Mohammed Mashhor, Maha Abdu Othman, Maryam H Mugri, Amit Porwal, Shankargouda Patil
{"title":"化学灭菌和高压灭菌前后复合树脂(双色度)色度指南与Vita陶瓷色度的比较。","authors":"Shekhar Gupta,&nbsp;Mohammed E Sayed,&nbsp;Bharti Gupta,&nbsp;Aditya Patel,&nbsp;Khurshid Mattoo,&nbsp;Noura Turki Alotaibi,&nbsp;Salha I Alnemi,&nbsp;Hossam F Jokhadar,&nbsp;Boshra Mohammed Mashhor,&nbsp;Maha Abdu Othman,&nbsp;Maryam H Mugri,&nbsp;Amit Porwal,&nbsp;Shankargouda Patil","doi":"10.12659/MSM.940949","DOIUrl":null,"url":null,"abstract":"<p><p>BACKGROUND This study aimed to compare a composite resin (Duo-Shade) shade guide with Vita ceramic shades before/after chemical and autoclave sterilization. MATERIAL AND METHODS Color values (L*a*b*) were recorded directly from shade tabs of prefabricated composite resin (Brilliant NG Universal Duo-Shade) and ceramic (Vita classic) shade guide with a calibrated spectrophotometer (Vita Easy Shade Advance 4.0). Seventy-two composite resin disk samples with 6 different shades (A1/B1, A2/B2, A3/D3, A3.5/B3, A4/C4, and C2/C3) (n=12 each) were divided into 2 groups (Gp) - Gp A (Autoclave) and Gp C (Chemical) (15 cycles) - to assess their influence on respective shades. Mean values calculated the color differences (ΔE) while differences in color values (L*a*b*) were graded on the National Bureau of Standards (NBS) 6-grade scale and assessed for Clinical Acceptance/Perceptible Threshold (CAT), (CPT). All differences were considered significant if the color difference ΔE was ≥3.3. RESULTS Only 2 out of 12 Shade tabs (C2C3, A4C4) of composite resin matched to Vita shade tab C2 and C4 (ΔE ≤3.3). Both groups showed notable color differences after respective sterilization protocols, with color differences in Gp A significantly higher than Gp C (DE ³3.3). Within groups, all shades in Gp A showed remarkably different color changes, with shade C2C3 and A1B1 being denoted as clinically unacceptable. CONCLUSIONS Manufacturer-provided shade guides do not match ceramic shades as claimed and chemical sterilization using 10% Deconex was associated with less color changes than with autoclave sterilization.</p>","PeriodicalId":18276,"journal":{"name":"Medical Science Monitor : International Medical Journal of Experimental and Clinical Research","volume":"29 ","pages":"e940949"},"PeriodicalIF":0.0000,"publicationDate":"2023-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/b6/98/medscimonit-29-e940949.PMC10318931.pdf","citationCount":"0","resultStr":"{\"title\":\"Comparison of Composite Resin (Duo-Shade) Shade Guide with Vita Ceramic Shades Before and After Chemical and Autoclave Sterilization.\",\"authors\":\"Shekhar Gupta,&nbsp;Mohammed E Sayed,&nbsp;Bharti Gupta,&nbsp;Aditya Patel,&nbsp;Khurshid Mattoo,&nbsp;Noura Turki Alotaibi,&nbsp;Salha I Alnemi,&nbsp;Hossam F Jokhadar,&nbsp;Boshra Mohammed Mashhor,&nbsp;Maha Abdu Othman,&nbsp;Maryam H Mugri,&nbsp;Amit Porwal,&nbsp;Shankargouda Patil\",\"doi\":\"10.12659/MSM.940949\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>BACKGROUND This study aimed to compare a composite resin (Duo-Shade) shade guide with Vita ceramic shades before/after chemical and autoclave sterilization. MATERIAL AND METHODS Color values (L*a*b*) were recorded directly from shade tabs of prefabricated composite resin (Brilliant NG Universal Duo-Shade) and ceramic (Vita classic) shade guide with a calibrated spectrophotometer (Vita Easy Shade Advance 4.0). Seventy-two composite resin disk samples with 6 different shades (A1/B1, A2/B2, A3/D3, A3.5/B3, A4/C4, and C2/C3) (n=12 each) were divided into 2 groups (Gp) - Gp A (Autoclave) and Gp C (Chemical) (15 cycles) - to assess their influence on respective shades. Mean values calculated the color differences (ΔE) while differences in color values (L*a*b*) were graded on the National Bureau of Standards (NBS) 6-grade scale and assessed for Clinical Acceptance/Perceptible Threshold (CAT), (CPT). All differences were considered significant if the color difference ΔE was ≥3.3. RESULTS Only 2 out of 12 Shade tabs (C2C3, A4C4) of composite resin matched to Vita shade tab C2 and C4 (ΔE ≤3.3). Both groups showed notable color differences after respective sterilization protocols, with color differences in Gp A significantly higher than Gp C (DE ³3.3). Within groups, all shades in Gp A showed remarkably different color changes, with shade C2C3 and A1B1 being denoted as clinically unacceptable. CONCLUSIONS Manufacturer-provided shade guides do not match ceramic shades as claimed and chemical sterilization using 10% Deconex was associated with less color changes than with autoclave sterilization.</p>\",\"PeriodicalId\":18276,\"journal\":{\"name\":\"Medical Science Monitor : International Medical Journal of Experimental and Clinical Research\",\"volume\":\"29 \",\"pages\":\"e940949\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-06-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/b6/98/medscimonit-29-e940949.PMC10318931.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Medical Science Monitor : International Medical Journal of Experimental and Clinical Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.12659/MSM.940949\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Science Monitor : International Medical Journal of Experimental and Clinical Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12659/MSM.940949","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本研究旨在比较化学灭菌和高压灭菌前后复合树脂(Duo-Shade)荫罩与Vita陶瓷荫罩的对比。材料和方法颜色值(L*a*b*)直接从预制复合树脂(Brilliant NG Universal Duo-Shade)和陶瓷(Vita classic)阴影指南的阴影标签上记录,并使用校准的分光光度计(Vita Easy shade Advance 4.0)。将72个6种不同色度(A1/B1、A2/B2、A3/D3、A3.5/B3、A4/C4和C2/C3)的复合树脂盘样品(n=12)分为2组(Gp) - Gp A(高压灭菌)和Gp C(化学)(15个循环),以评估其对各自色度的影响。平均值计算色差(ΔE),色差(L*a*b*)根据国家标准局(NBS) 6级量表进行分级,并进行临床接受/可感知阈值(CAT) (CPT)评估。如果色差ΔE≥3.3,则认为所有差异都具有显著性。结果复合树脂的12个遮光片中只有2个(C2C3、A4C4)与Vita遮光片C2和C4匹配(ΔE≤3.3)。两组在各自灭菌方案后颜色差异显著,其中Gp A的颜色差异显著高于Gp C (DE³3.3)。组内Gp A各色度颜色变化差异显著,其中色度C2C3和A1B1为临床不可接受。结论:制造商提供的色度指南与所声称的陶瓷色度不匹配,使用10%的Deconex进行化学灭菌与高压灭菌相比,颜色变化更少。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Comparison of Composite Resin (Duo-Shade) Shade Guide with Vita Ceramic Shades Before and After Chemical and Autoclave Sterilization.

Comparison of Composite Resin (Duo-Shade) Shade Guide with Vita Ceramic Shades Before and After Chemical and Autoclave Sterilization.

Comparison of Composite Resin (Duo-Shade) Shade Guide with Vita Ceramic Shades Before and After Chemical and Autoclave Sterilization.

BACKGROUND This study aimed to compare a composite resin (Duo-Shade) shade guide with Vita ceramic shades before/after chemical and autoclave sterilization. MATERIAL AND METHODS Color values (L*a*b*) were recorded directly from shade tabs of prefabricated composite resin (Brilliant NG Universal Duo-Shade) and ceramic (Vita classic) shade guide with a calibrated spectrophotometer (Vita Easy Shade Advance 4.0). Seventy-two composite resin disk samples with 6 different shades (A1/B1, A2/B2, A3/D3, A3.5/B3, A4/C4, and C2/C3) (n=12 each) were divided into 2 groups (Gp) - Gp A (Autoclave) and Gp C (Chemical) (15 cycles) - to assess their influence on respective shades. Mean values calculated the color differences (ΔE) while differences in color values (L*a*b*) were graded on the National Bureau of Standards (NBS) 6-grade scale and assessed for Clinical Acceptance/Perceptible Threshold (CAT), (CPT). All differences were considered significant if the color difference ΔE was ≥3.3. RESULTS Only 2 out of 12 Shade tabs (C2C3, A4C4) of composite resin matched to Vita shade tab C2 and C4 (ΔE ≤3.3). Both groups showed notable color differences after respective sterilization protocols, with color differences in Gp A significantly higher than Gp C (DE ³3.3). Within groups, all shades in Gp A showed remarkably different color changes, with shade C2C3 and A1B1 being denoted as clinically unacceptable. CONCLUSIONS Manufacturer-provided shade guides do not match ceramic shades as claimed and chemical sterilization using 10% Deconex was associated with less color changes than with autoclave sterilization.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信