陶瓷牙种植体:系统回顾和荟萃分析。

IF 16.4 1区 化学 Q1 CHEMISTRY, MULTIDISCIPLINARY
Jörg Neugebauer, Todd R Schoenbaum, Joan Pi-Anfruns, Min Yang, Bradley Lander, Markus B Blatz, Joseph P Fiorellini
{"title":"陶瓷牙种植体:系统回顾和荟萃分析。","authors":"Jörg Neugebauer,&nbsp;Todd R Schoenbaum,&nbsp;Joan Pi-Anfruns,&nbsp;Min Yang,&nbsp;Bradley Lander,&nbsp;Markus B Blatz,&nbsp;Joseph P Fiorellini","doi":"10.11607/jomi.10500","DOIUrl":null,"url":null,"abstract":"<p><p><b>Purpose:</b> To evaluate the performance of one- and two-piece ceramic implants regarding implant survival and success and patient satisfaction. <b>Materials and Methods:</b> This review followed the PRISMA 2020 guidelines using PICO format and analyzed clinical studies of partially or completely edentulous patients. The electronic search was conducted in PubMed/MEDLINE using Medical Subject Headings (MeSH) keywords related to dental zirconia ceramic implants, and 1,029 records were received for detailed screening. The data obtained from the literature were analyzed by single-arm, weighted meta-analyses using a random-effects model. Forest plots were used to synthesize pooled means and 95% CI for the change in marginal bone level (MBL) for short-term (1 year), mid-term (2 to 5 years), and long-term (over 5 years) follow-up time intervals. <b>Results:</b> Among the 155 included studies, the case reports, review articles, and preclinical studies were analyzed for background information. A meta-analysis was performed for 11 studies for one-piece implants. The results indicated that the MBL change after 1 year was 0.94 ± 0.11 mm, with a lower bound of 0.72 and an upper bound of 1.16. For the mid term, the MBL was 1.2 ± 0.14 mm with a lower bound of 0.92 and an upper bound of 1.48. For the long term, the MBL change was 1.24 ± 0.16 mm with a lower bound of 0.92 and an upper bound of 1.56. <b>Conclusion:</b> Based on this literature review, one-piece ceramic implants achieve osseointegration similar to titanium implants, with a stable MBL or a slight bone gain after an individual initial design depending on crestal remodeling. The risk of implant fracture is low for current commercially available implants. Immediate loading or temporization of the implants does not interfere with the course of osseointegration. Scientific evidence for two-piece implants is rare.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Ceramic Dental Implants: A Systematic Review and Meta-analysis.\",\"authors\":\"Jörg Neugebauer,&nbsp;Todd R Schoenbaum,&nbsp;Joan Pi-Anfruns,&nbsp;Min Yang,&nbsp;Bradley Lander,&nbsp;Markus B Blatz,&nbsp;Joseph P Fiorellini\",\"doi\":\"10.11607/jomi.10500\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Purpose:</b> To evaluate the performance of one- and two-piece ceramic implants regarding implant survival and success and patient satisfaction. <b>Materials and Methods:</b> This review followed the PRISMA 2020 guidelines using PICO format and analyzed clinical studies of partially or completely edentulous patients. The electronic search was conducted in PubMed/MEDLINE using Medical Subject Headings (MeSH) keywords related to dental zirconia ceramic implants, and 1,029 records were received for detailed screening. The data obtained from the literature were analyzed by single-arm, weighted meta-analyses using a random-effects model. Forest plots were used to synthesize pooled means and 95% CI for the change in marginal bone level (MBL) for short-term (1 year), mid-term (2 to 5 years), and long-term (over 5 years) follow-up time intervals. <b>Results:</b> Among the 155 included studies, the case reports, review articles, and preclinical studies were analyzed for background information. A meta-analysis was performed for 11 studies for one-piece implants. The results indicated that the MBL change after 1 year was 0.94 ± 0.11 mm, with a lower bound of 0.72 and an upper bound of 1.16. For the mid term, the MBL was 1.2 ± 0.14 mm with a lower bound of 0.92 and an upper bound of 1.48. For the long term, the MBL change was 1.24 ± 0.16 mm with a lower bound of 0.92 and an upper bound of 1.56. <b>Conclusion:</b> Based on this literature review, one-piece ceramic implants achieve osseointegration similar to titanium implants, with a stable MBL or a slight bone gain after an individual initial design depending on crestal remodeling. The risk of implant fracture is low for current commercially available implants. Immediate loading or temporization of the implants does not interfere with the course of osseointegration. Scientific evidence for two-piece implants is rare.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2023-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.11607/jomi.10500\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.11607/jomi.10500","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

目的:评价一片式和两片式陶瓷种植体在种植体存活、成功和患者满意度方面的性能。材料和方法:本综述采用PICO格式,遵循PRISMA 2020指南,分析部分或完全无牙患者的临床研究。使用与牙科氧化锆陶瓷种植体相关的医学主题词(MeSH)在PubMed/MEDLINE中进行电子检索,收到1029份记录进行详细筛选。从文献中获得的数据采用随机效应模型进行单臂加权meta分析。森林图用于综合短期(1年)、中期(2 - 5年)和长期(超过5年)随访时间间隔的边际骨水平(MBL)变化的汇总平均值和95% CI。结果:在纳入的155项研究中,分析了病例报告、综述文章和临床前研究的背景信息。对11项连体植入物的研究进行了荟萃分析。结果表明,1年后MBL变化为0.94±0.11 mm,下界为0.72,上界为1.16。中期MBL为1.2±0.14 mm,下界0.92,上界1.48。长期MBL变化为1.24±0.16 mm,下界0.92,上界1.56。结论:基于这篇文献综述,一体式陶瓷种植体实现了与钛种植体相似的骨整合,根据牙冠重塑的个体初始设计具有稳定的MBL或轻微的骨增加。目前市售的植入物骨折的风险很低。即刻加载或暂时放置种植体不会影响骨整合的过程。两件式植入的科学证据很少。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Ceramic Dental Implants: A Systematic Review and Meta-analysis.

Purpose: To evaluate the performance of one- and two-piece ceramic implants regarding implant survival and success and patient satisfaction. Materials and Methods: This review followed the PRISMA 2020 guidelines using PICO format and analyzed clinical studies of partially or completely edentulous patients. The electronic search was conducted in PubMed/MEDLINE using Medical Subject Headings (MeSH) keywords related to dental zirconia ceramic implants, and 1,029 records were received for detailed screening. The data obtained from the literature were analyzed by single-arm, weighted meta-analyses using a random-effects model. Forest plots were used to synthesize pooled means and 95% CI for the change in marginal bone level (MBL) for short-term (1 year), mid-term (2 to 5 years), and long-term (over 5 years) follow-up time intervals. Results: Among the 155 included studies, the case reports, review articles, and preclinical studies were analyzed for background information. A meta-analysis was performed for 11 studies for one-piece implants. The results indicated that the MBL change after 1 year was 0.94 ± 0.11 mm, with a lower bound of 0.72 and an upper bound of 1.16. For the mid term, the MBL was 1.2 ± 0.14 mm with a lower bound of 0.92 and an upper bound of 1.48. For the long term, the MBL change was 1.24 ± 0.16 mm with a lower bound of 0.92 and an upper bound of 1.56. Conclusion: Based on this literature review, one-piece ceramic implants achieve osseointegration similar to titanium implants, with a stable MBL or a slight bone gain after an individual initial design depending on crestal remodeling. The risk of implant fracture is low for current commercially available implants. Immediate loading or temporization of the implants does not interfere with the course of osseointegration. Scientific evidence for two-piece implants is rare.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信