{"title":"偏见,未完成的交响曲。","authors":"Abdurrahman Coşkun","doi":"10.11613/BM.2022.030402","DOIUrl":null,"url":null,"abstract":"<p><p>In laboratory medicine, mathematical equations are frequently used to calculate various parameters including bias, imprecision, measurement uncertainty, sigma metric (SM), creatinine clearance, LDL-cholesterol concentration, <i>etc</i>. Mathematical equations have strict limitations and cannot be used in all situations and are not open to manipulations. Recently, a paper \"Bias estimation for Sigma metric calculation: Arithmetic mean <i>versus</i> quadratic mean\" was published in Biochemia Medica. In the paper, the author criticized the approach of taking the arithmetic mean of the multiple biases to obtain a single bias and proposed a quadratic method to estimate the overall bias using external quality assurance services (EQAS) data for SM calculation. This approach does not fit the purpose and it should be noted that using the correct equation in calculations is as important as using the correct reagent in the measurement of the analytes, therefore before using an equation, its suitability should be checked and confirmed.</p>","PeriodicalId":9021,"journal":{"name":"Biochemia Medica","volume":"32 3","pages":"030402"},"PeriodicalIF":3.8000,"publicationDate":"2022-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9562803/pdf/","citationCount":"2","resultStr":"{\"title\":\"Bias, the unfinished symphony.\",\"authors\":\"Abdurrahman Coşkun\",\"doi\":\"10.11613/BM.2022.030402\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In laboratory medicine, mathematical equations are frequently used to calculate various parameters including bias, imprecision, measurement uncertainty, sigma metric (SM), creatinine clearance, LDL-cholesterol concentration, <i>etc</i>. Mathematical equations have strict limitations and cannot be used in all situations and are not open to manipulations. Recently, a paper \\\"Bias estimation for Sigma metric calculation: Arithmetic mean <i>versus</i> quadratic mean\\\" was published in Biochemia Medica. In the paper, the author criticized the approach of taking the arithmetic mean of the multiple biases to obtain a single bias and proposed a quadratic method to estimate the overall bias using external quality assurance services (EQAS) data for SM calculation. This approach does not fit the purpose and it should be noted that using the correct equation in calculations is as important as using the correct reagent in the measurement of the analytes, therefore before using an equation, its suitability should be checked and confirmed.</p>\",\"PeriodicalId\":9021,\"journal\":{\"name\":\"Biochemia Medica\",\"volume\":\"32 3\",\"pages\":\"030402\"},\"PeriodicalIF\":3.8000,\"publicationDate\":\"2022-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9562803/pdf/\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biochemia Medica\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.11613/BM.2022.030402\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"MEDICAL LABORATORY TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biochemia Medica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.11613/BM.2022.030402","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
In laboratory medicine, mathematical equations are frequently used to calculate various parameters including bias, imprecision, measurement uncertainty, sigma metric (SM), creatinine clearance, LDL-cholesterol concentration, etc. Mathematical equations have strict limitations and cannot be used in all situations and are not open to manipulations. Recently, a paper "Bias estimation for Sigma metric calculation: Arithmetic mean versus quadratic mean" was published in Biochemia Medica. In the paper, the author criticized the approach of taking the arithmetic mean of the multiple biases to obtain a single bias and proposed a quadratic method to estimate the overall bias using external quality assurance services (EQAS) data for SM calculation. This approach does not fit the purpose and it should be noted that using the correct equation in calculations is as important as using the correct reagent in the measurement of the analytes, therefore before using an equation, its suitability should be checked and confirmed.
期刊介绍:
Biochemia Medica is the official peer-reviewed journal of the Croatian Society of Medical Biochemistry and Laboratory Medicine. Journal provides a wide coverage of research in all aspects of clinical chemistry and laboratory medicine. Following categories fit into the scope of the Journal: general clinical chemistry, haematology and haemostasis, molecular diagnostics and endocrinology. Development, validation and verification of analytical techniques and methods applicable to clinical chemistry and laboratory medicine are welcome as well as studies dealing with laboratory organization, automation and quality control. Journal publishes on a regular basis educative preanalytical case reports (Preanalytical mysteries), articles dealing with applied biostatistics (Lessons in biostatistics) and research integrity (Research integrity corner).