前交叉韧带重建髌骨骨折:体外分析。

IF 0.5 4区 医学 Q4 ORTHOPEDICS
Marcelo DE Almeida Ferrer, Mariana DE Oliveira Lobo, Laís Maria Pinto Almeida, Anderson Freitas, Sílvio Leite DE Macedo Neto, Leonardo Morais Paiva, Leonardo Rigobello Battaglion
{"title":"前交叉韧带重建髌骨骨折:体外分析。","authors":"Marcelo DE Almeida Ferrer,&nbsp;Mariana DE Oliveira Lobo,&nbsp;Laís Maria Pinto Almeida,&nbsp;Anderson Freitas,&nbsp;Sílvio Leite DE Macedo Neto,&nbsp;Leonardo Morais Paiva,&nbsp;Leonardo Rigobello Battaglion","doi":"10.1590/1413-785220233102e259557","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To determine, by biomechanical analysis, safe patellar cut limits in anterior cruciate ligament (ACL) reconstruction that minimize fracture risks.</p><p><strong>Methods: </strong>From three-dimensional reconstruction, triangular cuts were made in the patella, with a depth of 6.5 mm and variable width and length (10 to 20 mm and 8 to 12 mm, respectively, both with an interval of 1 mm). The combinations of cuts constituted 55 models for tests, with five variations in width and 11 variations in length, tested with the finite element method (FEM).</p><p><strong>Results: </strong>The mean of the localized principal maximum (traction force) values was 4.36 Pa (SD 0.87 ± 0.76) and the localized principal minimum (compression force) was -4.33 Pa (SD 1.05 ± 1.11). Comparing width and length to the tension force of the values of the main maximum, we found statistical significance from 11 mm for width and 13 mm for length.</p><p><strong>Conclusion: </strong>In ACL reconstruction, the removal of the patellar bone fragment is safe for fragments smaller than 11 mm in width and 13 mm in length, which corresponds to 24% of the width and 28% of the length of the patella used. <b><i>Level of Evidence II, Comparative Prospective Study.</i></b></p>","PeriodicalId":55563,"journal":{"name":"Acta Ortopedica Brasileira","volume":null,"pages":null},"PeriodicalIF":0.5000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10158969/pdf/","citationCount":"0","resultStr":"{\"title\":\"PATELLAR FRACTURE IN ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION: IN VITRO ANALYSIS.\",\"authors\":\"Marcelo DE Almeida Ferrer,&nbsp;Mariana DE Oliveira Lobo,&nbsp;Laís Maria Pinto Almeida,&nbsp;Anderson Freitas,&nbsp;Sílvio Leite DE Macedo Neto,&nbsp;Leonardo Morais Paiva,&nbsp;Leonardo Rigobello Battaglion\",\"doi\":\"10.1590/1413-785220233102e259557\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>To determine, by biomechanical analysis, safe patellar cut limits in anterior cruciate ligament (ACL) reconstruction that minimize fracture risks.</p><p><strong>Methods: </strong>From three-dimensional reconstruction, triangular cuts were made in the patella, with a depth of 6.5 mm and variable width and length (10 to 20 mm and 8 to 12 mm, respectively, both with an interval of 1 mm). The combinations of cuts constituted 55 models for tests, with five variations in width and 11 variations in length, tested with the finite element method (FEM).</p><p><strong>Results: </strong>The mean of the localized principal maximum (traction force) values was 4.36 Pa (SD 0.87 ± 0.76) and the localized principal minimum (compression force) was -4.33 Pa (SD 1.05 ± 1.11). Comparing width and length to the tension force of the values of the main maximum, we found statistical significance from 11 mm for width and 13 mm for length.</p><p><strong>Conclusion: </strong>In ACL reconstruction, the removal of the patellar bone fragment is safe for fragments smaller than 11 mm in width and 13 mm in length, which corresponds to 24% of the width and 28% of the length of the patella used. <b><i>Level of Evidence II, Comparative Prospective Study.</i></b></p>\",\"PeriodicalId\":55563,\"journal\":{\"name\":\"Acta Ortopedica Brasileira\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10158969/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta Ortopedica Brasileira\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1590/1413-785220233102e259557\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Ortopedica Brasileira","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1590/1413-785220233102e259557","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

目的:通过生物力学分析,确定前交叉韧带(ACL)重建中安全的髌骨切面范围,以减少骨折风险。方法:从三维重建出发,在髌骨处做三角形切口,切口深度为6.5 mm,宽度和长度分别为10 ~ 20mm和8 ~ 12mm,间隔均为1mm。这些切割组合构成了55个用于测试的模型,其中宽度有5个变化,长度有11个变化,并采用有限元法进行了测试。结果:局部主最大值(牵引力)平均值为4.36 Pa (SD 0.87±0.76),局部主最小值(压缩力)平均值为-4.33 Pa (SD 1.05±1.11)。比较宽度和长度对拉力的主要最大值的值,我们发现从宽度11 mm到长度13 mm有统计学意义。结论:在ACL重建中,对于宽度小于11 mm、长度小于13 mm的碎片,即所使用髌骨宽度的24%和长度的28%,髌骨碎片的移除是安全的。证据水平II,比较前瞻性研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

PATELLAR FRACTURE IN ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION: IN VITRO ANALYSIS.

PATELLAR FRACTURE IN ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION: IN VITRO ANALYSIS.

PATELLAR FRACTURE IN ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION: IN VITRO ANALYSIS.

PATELLAR FRACTURE IN ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION: IN VITRO ANALYSIS.

Objective: To determine, by biomechanical analysis, safe patellar cut limits in anterior cruciate ligament (ACL) reconstruction that minimize fracture risks.

Methods: From three-dimensional reconstruction, triangular cuts were made in the patella, with a depth of 6.5 mm and variable width and length (10 to 20 mm and 8 to 12 mm, respectively, both with an interval of 1 mm). The combinations of cuts constituted 55 models for tests, with five variations in width and 11 variations in length, tested with the finite element method (FEM).

Results: The mean of the localized principal maximum (traction force) values was 4.36 Pa (SD 0.87 ± 0.76) and the localized principal minimum (compression force) was -4.33 Pa (SD 1.05 ± 1.11). Comparing width and length to the tension force of the values of the main maximum, we found statistical significance from 11 mm for width and 13 mm for length.

Conclusion: In ACL reconstruction, the removal of the patellar bone fragment is safe for fragments smaller than 11 mm in width and 13 mm in length, which corresponds to 24% of the width and 28% of the length of the patella used. Level of Evidence II, Comparative Prospective Study.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.90
自引率
14.30%
发文量
67
审稿时长
25 weeks
期刊介绍: A Revista Acta Ortopédica Brasileira, órgão oficial do Departamento de Ortopedia e Traumatologia da Faculdade de Medicina da Universidade de São Paulo (DOT/FMUSP), é publicada bimestralmente em seis edições ao ano (jan/fev, mar/abr, maio/jun, jul/ago, set/out e nov/dez) com versão em inglês disponível nos principais indexadores nacionais e internacionais e instituições de ensino do Brasil. Sendo hoje reconhecidamente uma importante contribuição para os especialistas da área com sua seriedade e árduo trabalho para as indexações já conquistadas.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信