Erica P McCune, David Q Le, Peter Lindholm, Kathryn R Nightingale, Paul A Dayton, Virginie Papadopoulou
{"title":"超声生物效应及其对潜水后持续监测安全的潜在影响。","authors":"Erica P McCune, David Q Le, Peter Lindholm, Kathryn R Nightingale, Paul A Dayton, Virginie Papadopoulou","doi":"10.28920/dhm52.2.136-148","DOIUrl":null,"url":null,"abstract":"<p><p>Ultrasound monitoring, both in the form of Doppler and 2D echocardiography, has been used post-dive to detect decompression bubbles circulating in the bloodstream. With large variability in both bubble time course and loads, it has been hypothesised that shorter periods between imaging, or even continuous imaging, could provide more accurate post-dive assessments. However, while considering applications of ultrasound imaging post-decompression, it may also be prudent to consider the possibility of ultrasound-induced bioeffects. Clinical ultrasound studies using microbubble contrast agents have shown bioeffect generation with acoustic powers much lower than those used in post-dive monitoring. However, to date no studies have specifically investigated potential bioeffect generation from continuous post-dive echocardiography. This review discusses what can be drawn from the current ultrasound and diving literature on the safety of bubble sonication and highlights areas where more studies are needed. An overview of the ultrasound-bubble mechanisms that lead to bioeffects and analyses of ultrasound contrast agent studies on bioeffect generation in the pulmonary and cardiovascular systems are provided to illustrate how bubbles under ultrasound can cause damage within the body. Along with clinical ultrasound studies, studies investigating the effects of decompression bubbles under ultrasound are analysed and open questions regarding continuous post-dive monitoring safety are discussed.</p>","PeriodicalId":11296,"journal":{"name":"Diving and hyperbaric medicine","volume":"52 2","pages":"136-148"},"PeriodicalIF":0.8000,"publicationDate":"2022-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9522608/pdf/DHM-52-136.pdf","citationCount":"2","resultStr":"{\"title\":\"Perspective on ultrasound bioeffects and possible implications for continuous post-dive monitoring safety.\",\"authors\":\"Erica P McCune, David Q Le, Peter Lindholm, Kathryn R Nightingale, Paul A Dayton, Virginie Papadopoulou\",\"doi\":\"10.28920/dhm52.2.136-148\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Ultrasound monitoring, both in the form of Doppler and 2D echocardiography, has been used post-dive to detect decompression bubbles circulating in the bloodstream. With large variability in both bubble time course and loads, it has been hypothesised that shorter periods between imaging, or even continuous imaging, could provide more accurate post-dive assessments. However, while considering applications of ultrasound imaging post-decompression, it may also be prudent to consider the possibility of ultrasound-induced bioeffects. Clinical ultrasound studies using microbubble contrast agents have shown bioeffect generation with acoustic powers much lower than those used in post-dive monitoring. However, to date no studies have specifically investigated potential bioeffect generation from continuous post-dive echocardiography. This review discusses what can be drawn from the current ultrasound and diving literature on the safety of bubble sonication and highlights areas where more studies are needed. An overview of the ultrasound-bubble mechanisms that lead to bioeffects and analyses of ultrasound contrast agent studies on bioeffect generation in the pulmonary and cardiovascular systems are provided to illustrate how bubbles under ultrasound can cause damage within the body. Along with clinical ultrasound studies, studies investigating the effects of decompression bubbles under ultrasound are analysed and open questions regarding continuous post-dive monitoring safety are discussed.</p>\",\"PeriodicalId\":11296,\"journal\":{\"name\":\"Diving and hyperbaric medicine\",\"volume\":\"52 2\",\"pages\":\"136-148\"},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2022-06-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9522608/pdf/DHM-52-136.pdf\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Diving and hyperbaric medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.28920/dhm52.2.136-148\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diving and hyperbaric medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.28920/dhm52.2.136-148","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH","Score":null,"Total":0}
Perspective on ultrasound bioeffects and possible implications for continuous post-dive monitoring safety.
Ultrasound monitoring, both in the form of Doppler and 2D echocardiography, has been used post-dive to detect decompression bubbles circulating in the bloodstream. With large variability in both bubble time course and loads, it has been hypothesised that shorter periods between imaging, or even continuous imaging, could provide more accurate post-dive assessments. However, while considering applications of ultrasound imaging post-decompression, it may also be prudent to consider the possibility of ultrasound-induced bioeffects. Clinical ultrasound studies using microbubble contrast agents have shown bioeffect generation with acoustic powers much lower than those used in post-dive monitoring. However, to date no studies have specifically investigated potential bioeffect generation from continuous post-dive echocardiography. This review discusses what can be drawn from the current ultrasound and diving literature on the safety of bubble sonication and highlights areas where more studies are needed. An overview of the ultrasound-bubble mechanisms that lead to bioeffects and analyses of ultrasound contrast agent studies on bioeffect generation in the pulmonary and cardiovascular systems are provided to illustrate how bubbles under ultrasound can cause damage within the body. Along with clinical ultrasound studies, studies investigating the effects of decompression bubbles under ultrasound are analysed and open questions regarding continuous post-dive monitoring safety are discussed.
期刊介绍:
Diving and Hyperbaric Medicine (DHM) is the combined journal of the South Pacific Underwater Medicine Society (SPUMS) and the European Underwater and Baromedical Society (EUBS). It seeks to publish papers of high quality on all aspects of diving and hyperbaric medicine of interest to diving medical professionals, physicians of all specialties, scientists, members of the diving and hyperbaric industries, and divers. Manuscripts must be offered exclusively to Diving and Hyperbaric Medicine, unless clearly authenticated copyright exemption accompaniesthe manuscript. All manuscripts will be subject to peer review. Accepted contributions will also be subject to editing.