三种不同光固化体系对不锈钢支架剪切强度的影响。

Q2 Dentistry
Shashank Soni, Richa Shree, Vijeta Patri, Gaurav Jasoria, Sapana Singh, Ashish Kushwah
{"title":"三种不同光固化体系对不锈钢支架剪切强度的影响。","authors":"Shashank Soni,&nbsp;Richa Shree,&nbsp;Vijeta Patri,&nbsp;Gaurav Jasoria,&nbsp;Sapana Singh,&nbsp;Ashish Kushwah","doi":"10.4103/jos.jos_83_22","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To evaluate and compare the shear bond strength of stainless-steel brackets using three different light curing units.</p><p><strong>Material and methods: </strong>Using three LED curing units (3M ESPE Elipar, Ivoclar bluephase, and Woodpecker I LED light cure), 120 precoated metal brackets (Gemini series, 3M Unitek) were cured. The shear bond strength was recorded using a universal testing machine.</p><p><strong>Result: </strong>The shear strength of the bracket in different light-curing systems was examined with ANOVA test. The mean shear strength of group A, group B, and group C were 16.03 ± 14.30 MPA, 16.86 ± 11.89 MPA, and 20.51 ± 19.40, respectively. The result of the analysis shows that there is a major difference in shear bond strength of these three different light-curing systems with F value = 3.94 and <i>P</i> value 0.04.</p><p><strong>Conclusion: </strong>We used three LED light-curing units with different intensities and manufacturing companies. The result showed that woodpecker I LED light had significantly highest mean SBS than the other two (Elipar LED curing light and 3M ESPE, Ivoclar bluephase).</p>","PeriodicalId":16604,"journal":{"name":"Journal of Orthodontic Science","volume":"12 ","pages":"20"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/bf/96/JOS-12-20.PMC10282525.pdf","citationCount":"0","resultStr":"{\"title\":\"Comparison of shear bond strength of bonded stainless steel brackets using three different light curing systems: An <i>in vitro</i> study.\",\"authors\":\"Shashank Soni,&nbsp;Richa Shree,&nbsp;Vijeta Patri,&nbsp;Gaurav Jasoria,&nbsp;Sapana Singh,&nbsp;Ashish Kushwah\",\"doi\":\"10.4103/jos.jos_83_22\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>To evaluate and compare the shear bond strength of stainless-steel brackets using three different light curing units.</p><p><strong>Material and methods: </strong>Using three LED curing units (3M ESPE Elipar, Ivoclar bluephase, and Woodpecker I LED light cure), 120 precoated metal brackets (Gemini series, 3M Unitek) were cured. The shear bond strength was recorded using a universal testing machine.</p><p><strong>Result: </strong>The shear strength of the bracket in different light-curing systems was examined with ANOVA test. The mean shear strength of group A, group B, and group C were 16.03 ± 14.30 MPA, 16.86 ± 11.89 MPA, and 20.51 ± 19.40, respectively. The result of the analysis shows that there is a major difference in shear bond strength of these three different light-curing systems with F value = 3.94 and <i>P</i> value 0.04.</p><p><strong>Conclusion: </strong>We used three LED light-curing units with different intensities and manufacturing companies. The result showed that woodpecker I LED light had significantly highest mean SBS than the other two (Elipar LED curing light and 3M ESPE, Ivoclar bluephase).</p>\",\"PeriodicalId\":16604,\"journal\":{\"name\":\"Journal of Orthodontic Science\",\"volume\":\"12 \",\"pages\":\"20\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/bf/96/JOS-12-20.PMC10282525.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Orthodontic Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/jos.jos_83_22\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orthodontic Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jos.jos_83_22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

摘要

目的:评价和比较三种不同光固化装置对不锈钢支架的剪切粘结强度。材料与方法:采用3种LED光固化装置(3M ESPE Elipar, Ivoclar bluephase, Woodpecker I LED光固化),固化120个预涂金属支架(Gemini系列,3M Unitek)。用万能试验机记录剪切粘接强度。结果:采用方差分析检验了不同光固化体系下支架的抗剪强度。A、B、C组的平均抗剪强度分别为16.03±14.30 MPA、16.86±11.89 MPA、20.51±19.40 MPA。分析结果表明,三种不同光固化体系的剪切粘结强度存在较大差异,F值为3.94,P值为0.04。结论:我们使用了三个不同强度的LED光固化单元和不同的制造公司。结果表明,啄木鸟I型LED光的平均SBS显著高于其他两种(Elipar LED固化光和3M ESPE, Ivoclar蓝相)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Comparison of shear bond strength of bonded stainless steel brackets using three different light curing systems: An <i>in vitro</i> study.

Comparison of shear bond strength of bonded stainless steel brackets using three different light curing systems: An <i>in vitro</i> study.

Comparison of shear bond strength of bonded stainless steel brackets using three different light curing systems: An <i>in vitro</i> study.

Comparison of shear bond strength of bonded stainless steel brackets using three different light curing systems: An in vitro study.

Objectives: To evaluate and compare the shear bond strength of stainless-steel brackets using three different light curing units.

Material and methods: Using three LED curing units (3M ESPE Elipar, Ivoclar bluephase, and Woodpecker I LED light cure), 120 precoated metal brackets (Gemini series, 3M Unitek) were cured. The shear bond strength was recorded using a universal testing machine.

Result: The shear strength of the bracket in different light-curing systems was examined with ANOVA test. The mean shear strength of group A, group B, and group C were 16.03 ± 14.30 MPA, 16.86 ± 11.89 MPA, and 20.51 ± 19.40, respectively. The result of the analysis shows that there is a major difference in shear bond strength of these three different light-curing systems with F value = 3.94 and P value 0.04.

Conclusion: We used three LED light-curing units with different intensities and manufacturing companies. The result showed that woodpecker I LED light had significantly highest mean SBS than the other two (Elipar LED curing light and 3M ESPE, Ivoclar bluephase).

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Orthodontic Science
Journal of Orthodontic Science Dentistry-Orthodontics
CiteScore
0.90
自引率
0.00%
发文量
46
审稿时长
19 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信