{"title":"胎儿心脏左心室功能评价:参考间隔和2D斑点跟踪超声心动图测量的观察者间变异性。","authors":"Liliana Gozar,&nbsp;Maria Oana Sasaran,&nbsp;Daniela Toma,&nbsp;Andreea Cerghit-Paler,&nbsp;Claudiu Molnar-Varlam,&nbsp;Claudiu Mărginean,&nbsp;Vlăduț Săsăran","doi":"10.11152/mu-4021","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>Measurement of myocardial strain using 2D speckle-tracking echocardiography can successfully quantify ventricular function, being considered superior to conventional echocardiography. This study aimed to establish reference intervals, interobserver agreements and reliability of two fetal echocardiographic parameters which reflect left ventricular myocardial function, left ventricular apical 4 chamber endo peak strain (AP4pLS) and ejection fraction (EF).</p><p><strong>Material and methods: </strong>We conducted a prospective study on 103 healthy fetuses. In each case, cardiac ultrasound images obtained were stored and afterwards were subject to offline 2D speckle-tracking echocardiographic analyses. In 15 randomly chosen subjects a second examiner also carried out an offline analysis of the 4-chamber view and the archived images, in order to assess inter-observer reproducibility and agreement level. Our study group was sub-divided into four different gestational age groups.</p><p><strong>Results: </strong>Reference ranges were established for the two measured parameters, AP4pLS and EF, which did not differ significantly between four different gestational age groups (p=0.98 and p=0.64) and neither correlated with gestational age progression (p=0.37 and p=0.08). An excellent level of agreement between the two examiners was found for the echocardiographic measurements, expressed through an intra-class correlation coefficient (ICC) value of 0.85 (0.62-0.94 for 95%CI) for AP4pLS and 0.78 (0.47- 0.92 for 95% CI) for EF.</p><p><strong>Conclusions: </strong>Speckle tracking AP4pLS and EF parameters are useful for assessment of ventricular myocardial function in healthy fetuses and can be reliably reproduced by two different skilled examiners. Further studies conducted on larger populations are required to standardize reference values of fetal speckle-tracking measurements.</p>","PeriodicalId":48781,"journal":{"name":"Medical Ultrasonography","volume":"25 2","pages":"168-174"},"PeriodicalIF":1.8000,"publicationDate":"2023-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Left ventricular function evaluation of the fetal heart: reference intervals and inter-observer variability of 2D speckle-tracking echocardiography measurements.\",\"authors\":\"Liliana Gozar,&nbsp;Maria Oana Sasaran,&nbsp;Daniela Toma,&nbsp;Andreea Cerghit-Paler,&nbsp;Claudiu Molnar-Varlam,&nbsp;Claudiu Mărginean,&nbsp;Vlăduț Săsăran\",\"doi\":\"10.11152/mu-4021\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aims: </strong>Measurement of myocardial strain using 2D speckle-tracking echocardiography can successfully quantify ventricular function, being considered superior to conventional echocardiography. This study aimed to establish reference intervals, interobserver agreements and reliability of two fetal echocardiographic parameters which reflect left ventricular myocardial function, left ventricular apical 4 chamber endo peak strain (AP4pLS) and ejection fraction (EF).</p><p><strong>Material and methods: </strong>We conducted a prospective study on 103 healthy fetuses. In each case, cardiac ultrasound images obtained were stored and afterwards were subject to offline 2D speckle-tracking echocardiographic analyses. In 15 randomly chosen subjects a second examiner also carried out an offline analysis of the 4-chamber view and the archived images, in order to assess inter-observer reproducibility and agreement level. Our study group was sub-divided into four different gestational age groups.</p><p><strong>Results: </strong>Reference ranges were established for the two measured parameters, AP4pLS and EF, which did not differ significantly between four different gestational age groups (p=0.98 and p=0.64) and neither correlated with gestational age progression (p=0.37 and p=0.08). An excellent level of agreement between the two examiners was found for the echocardiographic measurements, expressed through an intra-class correlation coefficient (ICC) value of 0.85 (0.62-0.94 for 95%CI) for AP4pLS and 0.78 (0.47- 0.92 for 95% CI) for EF.</p><p><strong>Conclusions: </strong>Speckle tracking AP4pLS and EF parameters are useful for assessment of ventricular myocardial function in healthy fetuses and can be reliably reproduced by two different skilled examiners. Further studies conducted on larger populations are required to standardize reference values of fetal speckle-tracking measurements.</p>\",\"PeriodicalId\":48781,\"journal\":{\"name\":\"Medical Ultrasonography\",\"volume\":\"25 2\",\"pages\":\"168-174\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2023-06-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Medical Ultrasonography\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.11152/mu-4021\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ACOUSTICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Ultrasonography","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.11152/mu-4021","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0

摘要

目的:利用二维斑点跟踪超声心动图测量心肌应变可以成功地量化心室功能,被认为优于传统超声心动图。本研究旨在建立反映左心室心肌功能、左心室尖室内室峰值应变(AP4pLS)和射血分数(EF)的两个胎儿超声心动图参数的参考区间、观察者间一致性和可靠性。材料和方法:我们对103例健康胎儿进行了前瞻性研究。在每种情况下,获得的心脏超声图像被存储,然后进行离线二维斑点跟踪超声心动图分析。在15名随机选择的受试者中,第二名审查员还对4室视图和存档图像进行了离线分析,以评估观察者之间的再现性和一致性水平。我们的研究组被细分为四个不同的胎龄组。结果:AP4pLS和EF两项测量参数的参考值范围在4个不同胎龄组间无显著差异(p=0.98和p=0.64),且与胎龄进展均无相关性(p=0.37和p=0.08)。在超声心动图测量中,两位检查者之间的一致性非常好,AP4pLS的类内相关系数(ICC)值为0.85 (95%CI为0.62-0.94),EF的类内相关系数(ICC)值为0.78 (95%CI为0.47- 0.92)。结论:斑点跟踪AP4pLS和EF参数可用于评估健康胎儿心室心肌功能,并可由两名熟练的检查人员可靠地再现。需要在更大的人群中进行进一步的研究来标准化胎儿斑点跟踪测量的参考值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Left ventricular function evaluation of the fetal heart: reference intervals and inter-observer variability of 2D speckle-tracking echocardiography measurements.

Aims: Measurement of myocardial strain using 2D speckle-tracking echocardiography can successfully quantify ventricular function, being considered superior to conventional echocardiography. This study aimed to establish reference intervals, interobserver agreements and reliability of two fetal echocardiographic parameters which reflect left ventricular myocardial function, left ventricular apical 4 chamber endo peak strain (AP4pLS) and ejection fraction (EF).

Material and methods: We conducted a prospective study on 103 healthy fetuses. In each case, cardiac ultrasound images obtained were stored and afterwards were subject to offline 2D speckle-tracking echocardiographic analyses. In 15 randomly chosen subjects a second examiner also carried out an offline analysis of the 4-chamber view and the archived images, in order to assess inter-observer reproducibility and agreement level. Our study group was sub-divided into four different gestational age groups.

Results: Reference ranges were established for the two measured parameters, AP4pLS and EF, which did not differ significantly between four different gestational age groups (p=0.98 and p=0.64) and neither correlated with gestational age progression (p=0.37 and p=0.08). An excellent level of agreement between the two examiners was found for the echocardiographic measurements, expressed through an intra-class correlation coefficient (ICC) value of 0.85 (0.62-0.94 for 95%CI) for AP4pLS and 0.78 (0.47- 0.92 for 95% CI) for EF.

Conclusions: Speckle tracking AP4pLS and EF parameters are useful for assessment of ventricular myocardial function in healthy fetuses and can be reliably reproduced by two different skilled examiners. Further studies conducted on larger populations are required to standardize reference values of fetal speckle-tracking measurements.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Medical Ultrasonography
Medical Ultrasonography RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
3.20
自引率
5.90%
发文量
79
期刊介绍: The journal aims to promote ultrasound diagnosis by publishing papers in a variety of categories, including editorial letters, original papers, review articles, pictorial essays, technical developments, case reports, letters to the editor or occasional special reports (fundamental, clinical as well as methodological and educational papers). The papers published cover the whole spectrum of the applications of diagnostic medical ultrasonography, including basic science and therapeutic applications. The journal hosts information regarding the society''s activities, scheduling of accredited training courses in ultrasound diagnosis, as well as the agenda of national and international scientific events.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信