{"title":"自旋标记磁共振成像中胰腺汁流可视化的平板标记与铅笔束标记的比较","authors":"Hideki Hoshi, Reiji Sugita, Yoshio Machida","doi":"10.2463/mrms.tn.2022-0132","DOIUrl":null,"url":null,"abstract":"<p><p>The usefulness of a highly targeted pencil beam (PB) label was compared with the commonly used slab label for direct visualization of pancreaticobiliary reflux using the time-spatial labeling inversion pulse (time-SLIP) technique. Signal profiles of flow phantom images obtained with a 1.5T MRI were analyzed. Both labels had similar labeling capabilities, but the edge characteristics of the PB label were blunt. Next, sixty-eight patients were classified into two groups according to the angle of the pancreaticobiliary ducts, and the displacement of the pancreatic ducts in respiratory fluctuation was measured. The results were approximately 7 mm in both groups. The blunt edge characteristics of the PB label suggest that it is robust to respiratory fluctuations. The overall labeling ability of the PB is comparable to that of the slab. In the larger angle of pancreaticobiliary ducts, the PB label may be able to label the pancreatic duct more selectively.</p>","PeriodicalId":18119,"journal":{"name":"Magnetic Resonance in Medical Sciences","volume":" ","pages":"502-513"},"PeriodicalIF":2.5000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11447465/pdf/","citationCount":"0","resultStr":"{\"title\":\"Comparison of Slab and Pencil Beam Labeling in Spin-labeled MR Imaging for Pancreatic Juice Flow Visualization.\",\"authors\":\"Hideki Hoshi, Reiji Sugita, Yoshio Machida\",\"doi\":\"10.2463/mrms.tn.2022-0132\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The usefulness of a highly targeted pencil beam (PB) label was compared with the commonly used slab label for direct visualization of pancreaticobiliary reflux using the time-spatial labeling inversion pulse (time-SLIP) technique. Signal profiles of flow phantom images obtained with a 1.5T MRI were analyzed. Both labels had similar labeling capabilities, but the edge characteristics of the PB label were blunt. Next, sixty-eight patients were classified into two groups according to the angle of the pancreaticobiliary ducts, and the displacement of the pancreatic ducts in respiratory fluctuation was measured. The results were approximately 7 mm in both groups. The blunt edge characteristics of the PB label suggest that it is robust to respiratory fluctuations. The overall labeling ability of the PB is comparable to that of the slab. In the larger angle of pancreaticobiliary ducts, the PB label may be able to label the pancreatic duct more selectively.</p>\",\"PeriodicalId\":18119,\"journal\":{\"name\":\"Magnetic Resonance in Medical Sciences\",\"volume\":\" \",\"pages\":\"502-513\"},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11447465/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Magnetic Resonance in Medical Sciences\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.2463/mrms.tn.2022-0132\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/6/21 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic Resonance in Medical Sciences","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2463/mrms.tn.2022-0132","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/6/21 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Comparison of Slab and Pencil Beam Labeling in Spin-labeled MR Imaging for Pancreatic Juice Flow Visualization.
The usefulness of a highly targeted pencil beam (PB) label was compared with the commonly used slab label for direct visualization of pancreaticobiliary reflux using the time-spatial labeling inversion pulse (time-SLIP) technique. Signal profiles of flow phantom images obtained with a 1.5T MRI were analyzed. Both labels had similar labeling capabilities, but the edge characteristics of the PB label were blunt. Next, sixty-eight patients were classified into two groups according to the angle of the pancreaticobiliary ducts, and the displacement of the pancreatic ducts in respiratory fluctuation was measured. The results were approximately 7 mm in both groups. The blunt edge characteristics of the PB label suggest that it is robust to respiratory fluctuations. The overall labeling ability of the PB is comparable to that of the slab. In the larger angle of pancreaticobiliary ducts, the PB label may be able to label the pancreatic duct more selectively.
期刊介绍:
Magnetic Resonance in Medical Sciences (MRMS or Magn
Reson Med Sci) is an international journal pursuing the
publication of original articles contributing to the progress
of magnetic resonance in the field of biomedical sciences
including technical developments and clinical applications.
MRMS is an official journal of the Japanese Society for
Magnetic Resonance in Medicine (JSMRM).