数字颌骨关系记录评估新的咬合垂直尺寸使用CAD/ cam制造牙色夹板:1例报告。

IF 1.8 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE
Janosch Goob, Otto Prandtner, Josef Schweiger, Jan-Frederik Güth, Daniel Edelhoff
{"title":"数字颌骨关系记录评估新的咬合垂直尺寸使用CAD/ cam制造牙色夹板:1例报告。","authors":"Janosch Goob, Otto Prandtner, Josef Schweiger, Jan-Frederik Güth, Daniel Edelhoff","doi":"10.3290/j.ijcd.b3960939","DOIUrl":null,"url":null,"abstract":"<p><p>Pronounced defects of the dental hard tissue can be caused by different etiologic factors. Most frequently, they are associated with changes in the vertical dimension of occlusion (VDO), which may also influence the condylar positions. These defects can lead to irreversible loss of tooth structure and have dramatic functional and esthetic consequences, often requiring complex rehabilitation. In this situation, CAD/CAM-fabricated occlusal splints made of tooth-colored polycarbonate are a proven and safe pretreatment approach in terms of esthetics and function. Rebuilding lost dental hard tissue to restore the occlusion and VDO to an adequate condylar position is a prerequisite for any sustainable and functional rehabilitation. In the future, digital systems will support this complex process, customizing it and making it simpler and more precise. The DMD-System (Ignident) provides patient-specific jaw movement data to optimize the CAD/CAM workflow. This system allows real movement patterns to be digitized and analyzed for functional and potential therapeutic purposes, integrating them into the dental and laboratory workflow. In the present case, the familiar tooth-colored CAD/CAM-fabricated occlusal splint is supplemented by digital centric jaw relation recording and individual movement data.</p>","PeriodicalId":48666,"journal":{"name":"International Journal of Computerized Dentistry","volume":"0 0","pages":"347-363"},"PeriodicalIF":1.8000,"publicationDate":"2023-11-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Digital jaw relation recording to evaluate a new vertical dimension of occlusion using CAD/CAM-fabricated tooth-colored splints: a case report.\",\"authors\":\"Janosch Goob, Otto Prandtner, Josef Schweiger, Jan-Frederik Güth, Daniel Edelhoff\",\"doi\":\"10.3290/j.ijcd.b3960939\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Pronounced defects of the dental hard tissue can be caused by different etiologic factors. Most frequently, they are associated with changes in the vertical dimension of occlusion (VDO), which may also influence the condylar positions. These defects can lead to irreversible loss of tooth structure and have dramatic functional and esthetic consequences, often requiring complex rehabilitation. In this situation, CAD/CAM-fabricated occlusal splints made of tooth-colored polycarbonate are a proven and safe pretreatment approach in terms of esthetics and function. Rebuilding lost dental hard tissue to restore the occlusion and VDO to an adequate condylar position is a prerequisite for any sustainable and functional rehabilitation. In the future, digital systems will support this complex process, customizing it and making it simpler and more precise. The DMD-System (Ignident) provides patient-specific jaw movement data to optimize the CAD/CAM workflow. This system allows real movement patterns to be digitized and analyzed for functional and potential therapeutic purposes, integrating them into the dental and laboratory workflow. In the present case, the familiar tooth-colored CAD/CAM-fabricated occlusal splint is supplemented by digital centric jaw relation recording and individual movement data.</p>\",\"PeriodicalId\":48666,\"journal\":{\"name\":\"International Journal of Computerized Dentistry\",\"volume\":\"0 0\",\"pages\":\"347-363\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2023-11-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Computerized Dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3290/j.ijcd.b3960939\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Computerized Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3290/j.ijcd.b3960939","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

牙硬组织的明显缺损可由不同的病因引起。最常见的是,它们与咬合的垂直尺寸(VDO)的变化有关,这也可能影响髁的位置。这些缺陷可导致牙齿结构的不可逆转的损失,并具有戏剧性的功能和美学后果,通常需要复杂的康复。在这种情况下,由牙色聚碳酸酯制成的CAD/ cam制造的咬合夹板在美观和功能方面是一种经过验证的安全的预处理方法。重建失去的牙硬组织以恢复咬合和VDO到适当的髁突位置是任何可持续和功能康复的先决条件。在未来,数字系统将支持这一复杂的过程,定制它,使其更简单,更精确。dmd系统(Ignident)提供患者特定的下颌运动数据,以优化CAD/CAM工作流程。该系统允许对真实的运动模式进行数字化和分析,用于功能和潜在的治疗目的,并将其集成到牙科和实验室工作流程中。在本案例中,我们使用数字中心颌关系记录和个体运动数据来补充我们熟悉的牙色CAD/ cam制作的咬合夹板。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Digital jaw relation recording to evaluate a new vertical dimension of occlusion using CAD/CAM-fabricated tooth-colored splints: a case report.

Pronounced defects of the dental hard tissue can be caused by different etiologic factors. Most frequently, they are associated with changes in the vertical dimension of occlusion (VDO), which may also influence the condylar positions. These defects can lead to irreversible loss of tooth structure and have dramatic functional and esthetic consequences, often requiring complex rehabilitation. In this situation, CAD/CAM-fabricated occlusal splints made of tooth-colored polycarbonate are a proven and safe pretreatment approach in terms of esthetics and function. Rebuilding lost dental hard tissue to restore the occlusion and VDO to an adequate condylar position is a prerequisite for any sustainable and functional rehabilitation. In the future, digital systems will support this complex process, customizing it and making it simpler and more precise. The DMD-System (Ignident) provides patient-specific jaw movement data to optimize the CAD/CAM workflow. This system allows real movement patterns to be digitized and analyzed for functional and potential therapeutic purposes, integrating them into the dental and laboratory workflow. In the present case, the familiar tooth-colored CAD/CAM-fabricated occlusal splint is supplemented by digital centric jaw relation recording and individual movement data.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal of Computerized Dentistry
International Journal of Computerized Dentistry Dentistry-Dentistry (miscellaneous)
CiteScore
2.90
自引率
0.00%
发文量
49
期刊介绍: This journal explores the myriad innovations in the emerging field of computerized dentistry and how to integrate them into clinical practice. The bulk of the journal is devoted to the science of computer-assisted dentistry, with research articles and clinical reports on all aspects of computer-based diagnostic and therapeutic applications, with special emphasis placed on CAD/CAM and image-processing systems. Articles also address the use of computer-based communication to support patient care, assess the quality of care, and enhance clinical decision making. The journal is presented in a bilingual format, with each issue offering three types of articles: science-based, application-based, and national society reports.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信