经支气管肺低温活检对弥漫性肺实质疾病诊断的诊断率和安全性:1.7 mm与1.9 mm探针的比较

IF 10.4 2区 医学 Q1 RESPIRATORY SYSTEM
Pulmonology Pub Date : 2025-12-31 Epub Date: 2025-01-21 DOI:10.1016/j.pulmoe.2023.04.003
C Ravaglia, F Sultani, S Piciucchi, A Dubini, A J De Grauw, S Martinello, S Oldani, S Maitan, F Stella, V Poletti
{"title":"经支气管肺低温活检对弥漫性肺实质疾病诊断的诊断率和安全性:1.7 mm与1.9 mm探针的比较","authors":"C Ravaglia, F Sultani, S Piciucchi, A Dubini, A J De Grauw, S Martinello, S Oldani, S Maitan, F Stella, V Poletti","doi":"10.1016/j.pulmoe.2023.04.003","DOIUrl":null,"url":null,"abstract":"<p><p><i>Purpose of the research</i>: transbronchial lung cryobiopsy has been recently accepted as a valid and less invasive alternative to surgical lung biopsy. The purpose of this randomized controlled study was to evaluate, for the first time, the quality and safety of biopsy specimens obtained by using the new disposable 1.7-mm cryoprobe compared with the standard re-usable 1.9 mm cryoprobe in the diagnosis of diffuse parenchymal lung diseases. <i>Methods</i>: 60 consecutive patients were prospectively enrolled and randomly assigned to two different groups: 1.9 mm (group A) and 1.7 mm (group B); primary endpoints were pathological and multidisciplinary diagnostic yield, sample size and complication rate. <i>Principal results</i>: the pathological diagnostic yield of cryobiopsy was 100% in group A and 93.3% in group B (<i>p</i> = 0.718); cryobiopsy median diameter was 6.8 mm in group A and 6.7 mm in group B (<i>p</i> = 0,5241). Pneumothorax occurred in 9 patients in group A and 10 in group B (<i>p</i> = 0.951); mild-to-moderate bleeding in 7 cases and 9 cases in group A and B respectively (<i>p</i> = 0.559). No death or severe adverse events were observed. <i>Conclusions</i>: there was no statistically significant difference between the two groups, regarding diagnostic yield, adverse events and sampling adequacy.</p>","PeriodicalId":54237,"journal":{"name":"Pulmonology","volume":" ","pages":"2416785"},"PeriodicalIF":10.4000,"publicationDate":"2025-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Diagnostic yield and safety of transbronchial lung cryobiopsy for diffuse parenchymal lung diseases diagnosis: Comparison between 1.7-mm and 1.9-mm probes.\",\"authors\":\"C Ravaglia, F Sultani, S Piciucchi, A Dubini, A J De Grauw, S Martinello, S Oldani, S Maitan, F Stella, V Poletti\",\"doi\":\"10.1016/j.pulmoe.2023.04.003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><i>Purpose of the research</i>: transbronchial lung cryobiopsy has been recently accepted as a valid and less invasive alternative to surgical lung biopsy. The purpose of this randomized controlled study was to evaluate, for the first time, the quality and safety of biopsy specimens obtained by using the new disposable 1.7-mm cryoprobe compared with the standard re-usable 1.9 mm cryoprobe in the diagnosis of diffuse parenchymal lung diseases. <i>Methods</i>: 60 consecutive patients were prospectively enrolled and randomly assigned to two different groups: 1.9 mm (group A) and 1.7 mm (group B); primary endpoints were pathological and multidisciplinary diagnostic yield, sample size and complication rate. <i>Principal results</i>: the pathological diagnostic yield of cryobiopsy was 100% in group A and 93.3% in group B (<i>p</i> = 0.718); cryobiopsy median diameter was 6.8 mm in group A and 6.7 mm in group B (<i>p</i> = 0,5241). Pneumothorax occurred in 9 patients in group A and 10 in group B (<i>p</i> = 0.951); mild-to-moderate bleeding in 7 cases and 9 cases in group A and B respectively (<i>p</i> = 0.559). No death or severe adverse events were observed. <i>Conclusions</i>: there was no statistically significant difference between the two groups, regarding diagnostic yield, adverse events and sampling adequacy.</p>\",\"PeriodicalId\":54237,\"journal\":{\"name\":\"Pulmonology\",\"volume\":\" \",\"pages\":\"2416785\"},\"PeriodicalIF\":10.4000,\"publicationDate\":\"2025-12-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pulmonology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1016/j.pulmoe.2023.04.003\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/1/21 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"RESPIRATORY SYSTEM\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pulmonology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.pulmoe.2023.04.003","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/21 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"RESPIRATORY SYSTEM","Score":null,"Total":0}
引用次数: 0

摘要

研究目的:经支气管肺低温活检最近被认为是手术肺活检的一种有效且侵入性较小的替代方法。本随机对照研究的目的是首次评价使用新型一次性1.7 mm冷冻探针与标准可重复使用1.9 mm冷冻探针获得的活检标本在弥漫性肺实质疾病诊断中的质量和安全性。方法:60例连续患者前瞻性入组,随机分为两组:1.9 mm (A组)和1.7 mm (B组);主要终点是病理和多学科诊断率、样本量和并发症发生率。主要结果:A组冷冻活检病理诊断率为100%,B组为93.3% (p = 0.718);A组冷冻切片中位直径为6.8 mm, B组为6.7 mm (p = 0,5241)。A组发生气胸9例,B组发生气胸10例(p = 0.951);A组轻中度出血7例,B组9例(p = 0.559)。未观察到死亡或严重不良事件。结论:两组在诊断率、不良事件和抽样充分性方面无统计学差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Diagnostic yield and safety of transbronchial lung cryobiopsy for diffuse parenchymal lung diseases diagnosis: Comparison between 1.7-mm and 1.9-mm probes.

Purpose of the research: transbronchial lung cryobiopsy has been recently accepted as a valid and less invasive alternative to surgical lung biopsy. The purpose of this randomized controlled study was to evaluate, for the first time, the quality and safety of biopsy specimens obtained by using the new disposable 1.7-mm cryoprobe compared with the standard re-usable 1.9 mm cryoprobe in the diagnosis of diffuse parenchymal lung diseases. Methods: 60 consecutive patients were prospectively enrolled and randomly assigned to two different groups: 1.9 mm (group A) and 1.7 mm (group B); primary endpoints were pathological and multidisciplinary diagnostic yield, sample size and complication rate. Principal results: the pathological diagnostic yield of cryobiopsy was 100% in group A and 93.3% in group B (p = 0.718); cryobiopsy median diameter was 6.8 mm in group A and 6.7 mm in group B (p = 0,5241). Pneumothorax occurred in 9 patients in group A and 10 in group B (p = 0.951); mild-to-moderate bleeding in 7 cases and 9 cases in group A and B respectively (p = 0.559). No death or severe adverse events were observed. Conclusions: there was no statistically significant difference between the two groups, regarding diagnostic yield, adverse events and sampling adequacy.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Pulmonology
Pulmonology Medicine-Pulmonary and Respiratory Medicine
CiteScore
14.30
自引率
5.10%
发文量
159
审稿时长
19 days
期刊介绍: Pulmonology (previously Revista Portuguesa de Pneumologia) is the official journal of the Portuguese Society of Pulmonology (Sociedade Portuguesa de Pneumologia/SPP). The journal publishes 6 issues per year and focuses on respiratory system diseases in adults and clinical research. It accepts various types of articles including peer-reviewed original articles, review articles, editorials, and opinion articles. The journal is published in English and is freely accessible through its website, as well as Medline and other databases. It is indexed in Science Citation Index Expanded, Journal of Citation Reports, Index Medicus/MEDLINE, Scopus, and EMBASE/Excerpta Medica.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信