在用于人体血液样本免疫监测的标准3激光全谱流式细胞仪上解析31种颜色。

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS
Linda Hammerich, Yaroslava Shevchenko, Jana Knorr, Wiebke Werner, Alix Bruneau, Frank Tacke
{"title":"在用于人体血液样本免疫监测的标准3激光全谱流式细胞仪上解析31种颜色。","authors":"Linda Hammerich,&nbsp;Yaroslava Shevchenko,&nbsp;Jana Knorr,&nbsp;Wiebke Werner,&nbsp;Alix Bruneau,&nbsp;Frank Tacke","doi":"10.1002/cyto.b.22126","DOIUrl":null,"url":null,"abstract":"<p>Immune monitoring of patients on a single-cell level is becoming increasingly important in various diseases. Due to the often very limited availability of human specimens and our increased understanding of the immune systems there is an increasing demand to analyze as many markers as possible simultaneously in one panel. Full spectrum flow cytometry is emerging as a powerful tool for immune monitoring since 5-laser instruments enable characterization of 40 parameters or more in a single sample. Nevertheless, even if only machines with fewer lasers are available, development of novel fluorophore families enables increasing panel sizes. Here, we demonstrate that careful panel design enables the use of 31-color panels on a 3-laser Cytek® Aurora cytometer for analyzing human peripheral blood leukocytes, without the need for custom configuration and using only commercially available fluorochromes. The panel presented here should serve as an example of a 31-fluorochrome combination that can be resolved on a 3-laser full spectrum cytometer and that can be adapted to comprise other (and possibly more) markers of interest depending on the research focus.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2023-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/cyto.b.22126","citationCount":"3","resultStr":"{\"title\":\"Resolving 31 colors on a standard 3-laser full spectrum flow cytometer for immune monitoring of human blood samples\",\"authors\":\"Linda Hammerich,&nbsp;Yaroslava Shevchenko,&nbsp;Jana Knorr,&nbsp;Wiebke Werner,&nbsp;Alix Bruneau,&nbsp;Frank Tacke\",\"doi\":\"10.1002/cyto.b.22126\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Immune monitoring of patients on a single-cell level is becoming increasingly important in various diseases. Due to the often very limited availability of human specimens and our increased understanding of the immune systems there is an increasing demand to analyze as many markers as possible simultaneously in one panel. Full spectrum flow cytometry is emerging as a powerful tool for immune monitoring since 5-laser instruments enable characterization of 40 parameters or more in a single sample. Nevertheless, even if only machines with fewer lasers are available, development of novel fluorophore families enables increasing panel sizes. Here, we demonstrate that careful panel design enables the use of 31-color panels on a 3-laser Cytek® Aurora cytometer for analyzing human peripheral blood leukocytes, without the need for custom configuration and using only commercially available fluorochromes. The panel presented here should serve as an example of a 31-fluorochrome combination that can be resolved on a 3-laser full spectrum cytometer and that can be adapted to comprise other (and possibly more) markers of interest depending on the research focus.</p>\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2023-05-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1002/cyto.b.22126\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/cyto.b.22126\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/cyto.b.22126","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 3

摘要

在各种疾病中,单细胞水平的患者免疫监测变得越来越重要。由于人类标本的可用性通常非常有限,并且我们对免疫系统的了解不断增加,因此在一个面板中同时分析尽可能多的标记物的需求越来越大。全谱流式细胞术正在成为一种强大的免疫监测工具,因为5激光仪器能够在单个样本中表征40个或更多的参数。然而,即使只有具有较少激光器的机器可用,新型荧光团家族的开发也能够增加面板尺寸。在这里,我们证明了仔细的面板设计可以在3激光Cytek®Aurora细胞仪上使用31种颜色的面板来分析人类外周血白细胞,而不需要自定义配置,并且只使用市售的荧光染料。这里介绍的小组应该作为31种荧光染料组合的例子,该组合可以在3酶全谱细胞仪上解析,并且可以根据研究重点调整为包括其他(可能更多)感兴趣的标记。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Resolving 31 colors on a standard 3-laser full spectrum flow cytometer for immune monitoring of human blood samples

Resolving 31 colors on a standard 3-laser full spectrum flow cytometer for immune monitoring of human blood samples

Immune monitoring of patients on a single-cell level is becoming increasingly important in various diseases. Due to the often very limited availability of human specimens and our increased understanding of the immune systems there is an increasing demand to analyze as many markers as possible simultaneously in one panel. Full spectrum flow cytometry is emerging as a powerful tool for immune monitoring since 5-laser instruments enable characterization of 40 parameters or more in a single sample. Nevertheless, even if only machines with fewer lasers are available, development of novel fluorophore families enables increasing panel sizes. Here, we demonstrate that careful panel design enables the use of 31-color panels on a 3-laser Cytek® Aurora cytometer for analyzing human peripheral blood leukocytes, without the need for custom configuration and using only commercially available fluorochromes. The panel presented here should serve as an example of a 31-fluorochrome combination that can be resolved on a 3-laser full spectrum cytometer and that can be adapted to comprise other (and possibly more) markers of interest depending on the research focus.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信