{"title":"隐性听力损失患者各频率纯音测听与失真产物耳声发射之间的相关性。","authors":"Yongqing Ding, Yachao Liu, Dong Li, Ruili Hu, Zedong Tian, Qi Xie","doi":"10.1080/02648725.2023.2209408","DOIUrl":null,"url":null,"abstract":"<p><p>To explore the correlation between pure tone audiometry at all frequencies and distortion product otoacoustic emission (DPOAE) of hidden hearing loss (HHL). The workers exposed to noise from a factory in Zhangjiakou (noise exposure group, <i>n</i> = 73) and normal young and middle-aged people recruited by society (control group, <i>n</i> = 77) from August 2021 to April 2022 were study subjects, and all of them underwent audiometry in clinic. Compared with the control group, the noise exposure group had significantly higher threshold by extended high-frequency audiometry at all frequencies and higher signal-to-noise ratio threshold (SNR50) (all <i>P</i> < 0.001), and higher amplitude ratio of SP to AP of the waveform induced by short sound at 96, 90, 80 and 70 dB nHL and lower SNR at 6 kHz and above (all P < 0.05). The pure tone audiometry was correlated with DPOAE test results at the frequencies of 6, 8, 9 and 10 kHz (<i>P</i> < 0.001). The results of speech audiometry in noise were related to the average SNR of DPOAE test at each frequency (<i>P</i> = 0.026,<i>r</i> = -0.265). The ratio of SP to AP in electrocochleogram recorded at the intensity of 96 dB nHL was correlated with the average SNR at 6 kHz and above in DPOAE test (<i>P</i> = 0.018,<i>r</i> = -0.461), and with the average auditory threshold at each frequency in extended high-frequency audiometry (<i>P</i> = 0.032, <i>r</i> = 0.421). DPOAE has certain value in detecting HHL.</p>","PeriodicalId":55355,"journal":{"name":"Biotechnology & Genetic Engineering Reviews","volume":" ","pages":"4250-4261"},"PeriodicalIF":6.5000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Correlation between pure tone audiometry at all frequencies and distortion product otoacoustic emission of patients with hidden hearing loss.\",\"authors\":\"Yongqing Ding, Yachao Liu, Dong Li, Ruili Hu, Zedong Tian, Qi Xie\",\"doi\":\"10.1080/02648725.2023.2209408\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>To explore the correlation between pure tone audiometry at all frequencies and distortion product otoacoustic emission (DPOAE) of hidden hearing loss (HHL). The workers exposed to noise from a factory in Zhangjiakou (noise exposure group, <i>n</i> = 73) and normal young and middle-aged people recruited by society (control group, <i>n</i> = 77) from August 2021 to April 2022 were study subjects, and all of them underwent audiometry in clinic. Compared with the control group, the noise exposure group had significantly higher threshold by extended high-frequency audiometry at all frequencies and higher signal-to-noise ratio threshold (SNR50) (all <i>P</i> < 0.001), and higher amplitude ratio of SP to AP of the waveform induced by short sound at 96, 90, 80 and 70 dB nHL and lower SNR at 6 kHz and above (all P < 0.05). The pure tone audiometry was correlated with DPOAE test results at the frequencies of 6, 8, 9 and 10 kHz (<i>P</i> < 0.001). The results of speech audiometry in noise were related to the average SNR of DPOAE test at each frequency (<i>P</i> = 0.026,<i>r</i> = -0.265). The ratio of SP to AP in electrocochleogram recorded at the intensity of 96 dB nHL was correlated with the average SNR at 6 kHz and above in DPOAE test (<i>P</i> = 0.018,<i>r</i> = -0.461), and with the average auditory threshold at each frequency in extended high-frequency audiometry (<i>P</i> = 0.032, <i>r</i> = 0.421). DPOAE has certain value in detecting HHL.</p>\",\"PeriodicalId\":55355,\"journal\":{\"name\":\"Biotechnology & Genetic Engineering Reviews\",\"volume\":\" \",\"pages\":\"4250-4261\"},\"PeriodicalIF\":6.5000,\"publicationDate\":\"2024-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biotechnology & Genetic Engineering Reviews\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1080/02648725.2023.2209408\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/5/12 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"BIOTECHNOLOGY & APPLIED MICROBIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biotechnology & Genetic Engineering Reviews","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1080/02648725.2023.2209408","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/5/12 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"BIOTECHNOLOGY & APPLIED MICROBIOLOGY","Score":null,"Total":0}
引用次数: 0
摘要
目的 探讨各频率纯音测听与隐性听力损失(HHL)的失真产物耳声发射(DPOAE)之间的相关性。以2021年8月至2022年4月期间暴露于张家口某工厂噪声的工人(噪声暴露组,n = 73)和社会招聘的正常中青年(对照组,n = 77)为研究对象,对他们全部进行门诊听力测定。与对照组相比,噪声暴露组所有频率的扩展高频测听阈值均明显升高,信噪比阈值(SNR50)也明显升高(均P P P = 0.026,r = -0.265)。在 96 dB nHL 强度下记录的电听图中 SP 与 AP 的比值与 DPOAE 测试中 6 kHz 及以上频率的平均信噪比相关(P = 0.018,r = -0.461),与扩展高频测听中各频率的平均听阈相关(P = 0.032,r = 0.421)。DPOAE 对检测 HHL 有一定价值。
Correlation between pure tone audiometry at all frequencies and distortion product otoacoustic emission of patients with hidden hearing loss.
To explore the correlation between pure tone audiometry at all frequencies and distortion product otoacoustic emission (DPOAE) of hidden hearing loss (HHL). The workers exposed to noise from a factory in Zhangjiakou (noise exposure group, n = 73) and normal young and middle-aged people recruited by society (control group, n = 77) from August 2021 to April 2022 were study subjects, and all of them underwent audiometry in clinic. Compared with the control group, the noise exposure group had significantly higher threshold by extended high-frequency audiometry at all frequencies and higher signal-to-noise ratio threshold (SNR50) (all P < 0.001), and higher amplitude ratio of SP to AP of the waveform induced by short sound at 96, 90, 80 and 70 dB nHL and lower SNR at 6 kHz and above (all P < 0.05). The pure tone audiometry was correlated with DPOAE test results at the frequencies of 6, 8, 9 and 10 kHz (P < 0.001). The results of speech audiometry in noise were related to the average SNR of DPOAE test at each frequency (P = 0.026,r = -0.265). The ratio of SP to AP in electrocochleogram recorded at the intensity of 96 dB nHL was correlated with the average SNR at 6 kHz and above in DPOAE test (P = 0.018,r = -0.461), and with the average auditory threshold at each frequency in extended high-frequency audiometry (P = 0.032, r = 0.421). DPOAE has certain value in detecting HHL.
期刊介绍:
Biotechnology & Genetic Engineering Reviews publishes major invited review articles covering important developments in industrial, agricultural and medical applications of biotechnology.