评估磷脂酰乙醇(PEth)临界值的敏感性和特异性,以识别酒精暴露的妊娠

IF 2.9 Q2 TOXICOLOGY
Julie M. Hasken , Anna-Susan Marais , Marlene M. de Vries , Wendy O. Kalberg , David Buckley , Charles D.H. Parry , Soraya Seedat , Philip A. May
{"title":"评估磷脂酰乙醇(PEth)临界值的敏感性和特异性,以识别酒精暴露的妊娠","authors":"Julie M. Hasken ,&nbsp;Anna-Susan Marais ,&nbsp;Marlene M. de Vries ,&nbsp;Wendy O. Kalberg ,&nbsp;David Buckley ,&nbsp;Charles D.H. Parry ,&nbsp;Soraya Seedat ,&nbsp;Philip A. May","doi":"10.1016/j.crtox.2023.100105","DOIUrl":null,"url":null,"abstract":"<div><p>In the literature on alcohol use biomarkers, there has been debate as to what a valid and/or utilitarian cut off level should be for various research applications. In this manuscript, we assessed the sensitivity and specificity of multiple cutoff values for phosphatidylethanol (PEth) from bloodspots relative to self-report, the Alcohol Use Disorder Identification Test (AUDIT) scores, and another alcohol use biomarker ethyl glucuronide (EtG) from fingernails in a sample of 222 pregnant women in the Western Cape Province of South Africa. Receiver operating characteristic (ROC) curves were used to assess the area under the curve (AUC) and assess PEth cutoff values of ≥2, ≥4, ≥8, ≥14, and ≥20 nanograms per milliliter (ng/ml). The highest AUC value was attained when PEth was compared to an AUDIT score of 1 or more. Depending on the cutoff used to determine alcohol consumption, PEth identified 47%–70% of the individuals as alcohol-consuming while 62.6%–75.2% were identified by self-reported measures, and 35.6% were identified by EtG. In this sample, sensitivity and accuracy were highest at less stringent PEth cutoffs when compared to self-report, AUDIT score of 1 or more, 5 or more, 8 or more, and EtG ≥ 8 picograms per milligram (pg/mg). For research purposes, less stringent cutoffs, such as PEth ≥ 8 ng/ml, may be considered a valid, positive cutoff for identifying women who consume alcohol during pregnancy in this population. A cutoff of PEth ≥ 20 ng/ml may miss individuals who reported consuming alcohol (false negatives).</p></div>","PeriodicalId":11236,"journal":{"name":"Current Research in Toxicology","volume":"4 ","pages":"Article 100105"},"PeriodicalIF":2.9000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10123138/pdf/main.pdf","citationCount":"3","resultStr":"{\"title\":\"Assessing the sensitivity and specificity of phosphatidylethanol (PEth) cutoffs to identify alcohol exposed pregnancies\",\"authors\":\"Julie M. Hasken ,&nbsp;Anna-Susan Marais ,&nbsp;Marlene M. de Vries ,&nbsp;Wendy O. Kalberg ,&nbsp;David Buckley ,&nbsp;Charles D.H. Parry ,&nbsp;Soraya Seedat ,&nbsp;Philip A. May\",\"doi\":\"10.1016/j.crtox.2023.100105\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>In the literature on alcohol use biomarkers, there has been debate as to what a valid and/or utilitarian cut off level should be for various research applications. In this manuscript, we assessed the sensitivity and specificity of multiple cutoff values for phosphatidylethanol (PEth) from bloodspots relative to self-report, the Alcohol Use Disorder Identification Test (AUDIT) scores, and another alcohol use biomarker ethyl glucuronide (EtG) from fingernails in a sample of 222 pregnant women in the Western Cape Province of South Africa. Receiver operating characteristic (ROC) curves were used to assess the area under the curve (AUC) and assess PEth cutoff values of ≥2, ≥4, ≥8, ≥14, and ≥20 nanograms per milliliter (ng/ml). The highest AUC value was attained when PEth was compared to an AUDIT score of 1 or more. Depending on the cutoff used to determine alcohol consumption, PEth identified 47%–70% of the individuals as alcohol-consuming while 62.6%–75.2% were identified by self-reported measures, and 35.6% were identified by EtG. In this sample, sensitivity and accuracy were highest at less stringent PEth cutoffs when compared to self-report, AUDIT score of 1 or more, 5 or more, 8 or more, and EtG ≥ 8 picograms per milligram (pg/mg). For research purposes, less stringent cutoffs, such as PEth ≥ 8 ng/ml, may be considered a valid, positive cutoff for identifying women who consume alcohol during pregnancy in this population. A cutoff of PEth ≥ 20 ng/ml may miss individuals who reported consuming alcohol (false negatives).</p></div>\",\"PeriodicalId\":11236,\"journal\":{\"name\":\"Current Research in Toxicology\",\"volume\":\"4 \",\"pages\":\"Article 100105\"},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10123138/pdf/main.pdf\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Current Research in Toxicology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2666027X23000038\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"TOXICOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Research in Toxicology","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666027X23000038","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"TOXICOLOGY","Score":null,"Total":0}
引用次数: 3

摘要

在关于酒精使用生物标志物的文献中,对于各种研究应用的有效和/或实用截止水平应该是多少,一直存在争议。在这篇手稿中,我们在南非西开普省222名孕妇的样本中评估了血泊中磷脂酰乙醇(PEth)的多个临界值相对于自我报告、酒精使用障碍识别测试(AUDIT)评分和指甲中另一种酒精使用生物标志物乙基葡糖苷酸(EtG)的敏感性和特异性。受试者工作特性(ROC)曲线用于评估曲线下面积(AUC),并评估PEth临界值≥2、≥4、≥8、≥14和≥20纳克/毫升(ng/ml)。当将PEth与AUDIT得分1或更高时,获得最高AUC值。根据用于确定饮酒量的临界值,PEth确定47%–70%的人饮酒,62.6%–75.2%的人通过自我报告的措施确定,35.6%的人通过EtG确定。在该样本中,与自我报告、AUDIT评分为1或以上、5或以上、8或以上以及EtG≥8皮克/毫克(pg/mg)相比,在不太严格的PEth截止值下,敏感性和准确性最高。出于研究目的,不太严格的临界值,如PEth≥8 ng/ml,可以被认为是识别该人群中怀孕期间饮酒女性的有效、积极的临界值。PEth≥20 ng/ml的临界值可能会漏掉报告饮酒的个体(假阴性)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Assessing the sensitivity and specificity of phosphatidylethanol (PEth) cutoffs to identify alcohol exposed pregnancies

Assessing the sensitivity and specificity of phosphatidylethanol (PEth) cutoffs to identify alcohol exposed pregnancies

In the literature on alcohol use biomarkers, there has been debate as to what a valid and/or utilitarian cut off level should be for various research applications. In this manuscript, we assessed the sensitivity and specificity of multiple cutoff values for phosphatidylethanol (PEth) from bloodspots relative to self-report, the Alcohol Use Disorder Identification Test (AUDIT) scores, and another alcohol use biomarker ethyl glucuronide (EtG) from fingernails in a sample of 222 pregnant women in the Western Cape Province of South Africa. Receiver operating characteristic (ROC) curves were used to assess the area under the curve (AUC) and assess PEth cutoff values of ≥2, ≥4, ≥8, ≥14, and ≥20 nanograms per milliliter (ng/ml). The highest AUC value was attained when PEth was compared to an AUDIT score of 1 or more. Depending on the cutoff used to determine alcohol consumption, PEth identified 47%–70% of the individuals as alcohol-consuming while 62.6%–75.2% were identified by self-reported measures, and 35.6% were identified by EtG. In this sample, sensitivity and accuracy were highest at less stringent PEth cutoffs when compared to self-report, AUDIT score of 1 or more, 5 or more, 8 or more, and EtG ≥ 8 picograms per milligram (pg/mg). For research purposes, less stringent cutoffs, such as PEth ≥ 8 ng/ml, may be considered a valid, positive cutoff for identifying women who consume alcohol during pregnancy in this population. A cutoff of PEth ≥ 20 ng/ml may miss individuals who reported consuming alcohol (false negatives).

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Current Research in Toxicology
Current Research in Toxicology Environmental Science-Health, Toxicology and Mutagenesis
CiteScore
4.70
自引率
3.00%
发文量
33
审稿时长
82 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信