{"title":"使用SLIPTA检查表评估实验室为国际联合委员会认证的准备情况。","authors":"Abdul K El Karaaoui,&nbsp;Nada Assaf","doi":"10.4102/ajlm.v12i1.2044","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The Stepwise Laboratory Improvement Process Towards Accreditation (SLIPTA) helps prepare laboratories in low- and middle-income countries to achieve international accreditation aligned with the ISO 15189:2012 standards. Accreditation by the Joint Commission International (JCI) is among the highest sought by hospitals worldwide. While the readiness of laboratories with a five-star SLIPTA score to undergo ISO 15189:2012 accreditation was recently assessed, the compliance of the SLIPTA checklist with JCI is still unknown.</p><p><strong>Objective: </strong>The study evaluated the SLIPTA checklist's utility in assessing laboratories to meet the JCI standards.</p><p><strong>Methods: </strong>We conducted a detailed gap analysis between SLIPTA and JCI laboratory standards from January 2021 to January 2022. We cross-matched the JCI standard requirements to SLIPTA clauses and categorised each standard into 'met', 'partially met', and 'not met'. We highlighted similarities, discrepancies, and improvement areas.</p><p><strong>Results: </strong>A total of 109 JCI standards were included. The SLIPTA checklist completely met 61 standards, partially met four, but did not meet 44. The unmet JCI standards focused on the quality planning, control, and improvement sections. Healthcare organisation management and quality control processes, including selecting an accredited reference laboratory, collecting quality management data, creating of post-analytical policies and procedures, and validating monitoring systems, constitute the basis of this preparation.</p><p><strong>Conclusion: </strong>The SLIPTA checklist covers major quality management system elements of the JCI standards for laboratories. However, some components should be addressed to assure readiness for JCI accreditation.</p><p><strong>What this study adds: </strong>This study identified additional areas not covered by the SLIPTA checklist that are required for JCI accreditation.</p>","PeriodicalId":45412,"journal":{"name":"African Journal of Laboratory Medicine","volume":null,"pages":null},"PeriodicalIF":1.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10091060/pdf/","citationCount":"1","resultStr":"{\"title\":\"Using the SLIPTA checklist to assess laboratory readiness for Joint Commission International accreditation.\",\"authors\":\"Abdul K El Karaaoui,&nbsp;Nada Assaf\",\"doi\":\"10.4102/ajlm.v12i1.2044\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The Stepwise Laboratory Improvement Process Towards Accreditation (SLIPTA) helps prepare laboratories in low- and middle-income countries to achieve international accreditation aligned with the ISO 15189:2012 standards. Accreditation by the Joint Commission International (JCI) is among the highest sought by hospitals worldwide. While the readiness of laboratories with a five-star SLIPTA score to undergo ISO 15189:2012 accreditation was recently assessed, the compliance of the SLIPTA checklist with JCI is still unknown.</p><p><strong>Objective: </strong>The study evaluated the SLIPTA checklist's utility in assessing laboratories to meet the JCI standards.</p><p><strong>Methods: </strong>We conducted a detailed gap analysis between SLIPTA and JCI laboratory standards from January 2021 to January 2022. We cross-matched the JCI standard requirements to SLIPTA clauses and categorised each standard into 'met', 'partially met', and 'not met'. We highlighted similarities, discrepancies, and improvement areas.</p><p><strong>Results: </strong>A total of 109 JCI standards were included. The SLIPTA checklist completely met 61 standards, partially met four, but did not meet 44. The unmet JCI standards focused on the quality planning, control, and improvement sections. Healthcare organisation management and quality control processes, including selecting an accredited reference laboratory, collecting quality management data, creating of post-analytical policies and procedures, and validating monitoring systems, constitute the basis of this preparation.</p><p><strong>Conclusion: </strong>The SLIPTA checklist covers major quality management system elements of the JCI standards for laboratories. However, some components should be addressed to assure readiness for JCI accreditation.</p><p><strong>What this study adds: </strong>This study identified additional areas not covered by the SLIPTA checklist that are required for JCI accreditation.</p>\",\"PeriodicalId\":45412,\"journal\":{\"name\":\"African Journal of Laboratory Medicine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10091060/pdf/\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"African Journal of Laboratory Medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4102/ajlm.v12i1.2044\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"MEDICINE, RESEARCH & EXPERIMENTAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"African Journal of Laboratory Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4102/ajlm.v12i1.2044","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 1

摘要

背景:朝向认可的逐步实验室改进过程(SLIPTA)帮助中低收入国家的实验室做好准备,以获得符合ISO 15189:2012标准的国际认可。国际联合委员会(JCI)的认证是全球医院寻求的最高认证之一。虽然最近评估了具有五星级SLIPTA分数的实验室是否准备接受ISO 15189:2012认证,但SLIPTA清单与JCI的合合性仍然未知。目的:评价SLIPTA检查表在评估实验室是否达到JCI标准中的实用性。方法:对2021年1月至2022年1月期间SLIPTA与JCI实验室标准进行了详细的差距分析。我们将JCI标准要求与SLIPTA条款进行交叉匹配,并将每个标准分为“满足”、“部分满足”和“未满足”。我们强调了相似之处、差异和改进的地方。结果:共纳入JCI标准109项。SLIPTA清单完全满足61项标准,部分满足4项,但不满足44项。未满足的JCI标准集中在质量计划、控制和改进部分。医疗保健组织的管理和质量控制过程,包括选择认可的参考实验室,收集质量管理数据,创建分析后政策和程序,以及验证监控系统,构成了这一准备的基础。结论:SLIPTA清单涵盖了JCI实验室标准的主要质量管理体系要素。但是,应该解决一些问题,以确保为JCI认证做好准备。本研究补充的内容:本研究确定了JCI认证所需的SLIPTA清单未涵盖的其他领域。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Using the SLIPTA checklist to assess laboratory readiness for Joint Commission International accreditation.

Background: The Stepwise Laboratory Improvement Process Towards Accreditation (SLIPTA) helps prepare laboratories in low- and middle-income countries to achieve international accreditation aligned with the ISO 15189:2012 standards. Accreditation by the Joint Commission International (JCI) is among the highest sought by hospitals worldwide. While the readiness of laboratories with a five-star SLIPTA score to undergo ISO 15189:2012 accreditation was recently assessed, the compliance of the SLIPTA checklist with JCI is still unknown.

Objective: The study evaluated the SLIPTA checklist's utility in assessing laboratories to meet the JCI standards.

Methods: We conducted a detailed gap analysis between SLIPTA and JCI laboratory standards from January 2021 to January 2022. We cross-matched the JCI standard requirements to SLIPTA clauses and categorised each standard into 'met', 'partially met', and 'not met'. We highlighted similarities, discrepancies, and improvement areas.

Results: A total of 109 JCI standards were included. The SLIPTA checklist completely met 61 standards, partially met four, but did not meet 44. The unmet JCI standards focused on the quality planning, control, and improvement sections. Healthcare organisation management and quality control processes, including selecting an accredited reference laboratory, collecting quality management data, creating of post-analytical policies and procedures, and validating monitoring systems, constitute the basis of this preparation.

Conclusion: The SLIPTA checklist covers major quality management system elements of the JCI standards for laboratories. However, some components should be addressed to assure readiness for JCI accreditation.

What this study adds: This study identified additional areas not covered by the SLIPTA checklist that are required for JCI accreditation.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
African Journal of Laboratory Medicine
African Journal of Laboratory Medicine MEDICINE, RESEARCH & EXPERIMENTAL-
CiteScore
1.70
自引率
9.10%
发文量
53
审稿时长
12 weeks
期刊介绍: The African Journal of Laboratory Medicine, the official journal of ASLM, focuses on the role of the laboratory and its professionals in the clinical and public healthcare sectors,and is specifically based on an African frame of reference. Emphasis is on all aspects that promote and contribute to the laboratory medicine practices of Africa. This includes, amongst others: laboratories, biomedical scientists and clinicians, medical community, public health officials and policy makers, laboratory systems and policies (translation of laboratory knowledge, practices and technologies in clinical care), interfaces of laboratory with medical science, laboratory-based epidemiology, laboratory investigations, evidence-based effectiveness in real world (actual) settings.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信