Aml A Emam, Eglal A Abdelaleem, Fatma Magdy, Ahmed M Gouda, Fatma F Abdallah
{"title":"二甲双胍复方制剂的生态友好型色谱分析;含量均匀性测试和毒性分析。","authors":"Aml A Emam, Eglal A Abdelaleem, Fatma Magdy, Ahmed M Gouda, Fatma F Abdallah","doi":"10.1093/chromsci/bmad026","DOIUrl":null,"url":null,"abstract":"<p><p>Accurate, sensitive and green HPTLC chromatographic method was proposed for simultaneous determination of metformin, glipizide and sitagliptin in the presence of metformin potential toxic impurities melamine and cyanoguanidine. The separation was completed on silica gel HPTLC F254 plates using a mixture of ethyl acetate: methanol: ammonia: formic acid (7: 2: 0.2: 0.2, by volume) as a developing system with UV scanning for the developed bands at 235 nm. The Rf values for metformin, glipizide, sitagliptin, melamine and cyanoguanidine were 0.17, 0.84, 0.67, 0.47 and 0.75, respectively. Linear responses were observed in the ranges of 0.2-3, 0.07-1.5, 1.5-5, 0.8-4 and 0.4-2 μg/band with correlation coefficients of 0.9999, 0.9998, 0.9997, 0.9996 and 0.9998 for metformin, glipizide, sitagliptin, melamine and cyanoguanidine, respectively. The proposed method was validated as per ICH criteria with respect to linearity, accuracy, precision, specificity and robustness. The validated method was successfully applied for determination of the studied drugs in Janumet® and Engilor® tablets; also, the results were statistically compared to those obtained by the reported spectrophotometric method and no significant difference was found between them. This method permitted the accurate simultaneous determination of the studied drugs, indicating its ability to be used for routine quality control assays of these drugs.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Ecofriendly Chromatographic Assay of Metformin Combinations; Content Uniformity Tests and Toxicity Profiling.\",\"authors\":\"Aml A Emam, Eglal A Abdelaleem, Fatma Magdy, Ahmed M Gouda, Fatma F Abdallah\",\"doi\":\"10.1093/chromsci/bmad026\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Accurate, sensitive and green HPTLC chromatographic method was proposed for simultaneous determination of metformin, glipizide and sitagliptin in the presence of metformin potential toxic impurities melamine and cyanoguanidine. The separation was completed on silica gel HPTLC F254 plates using a mixture of ethyl acetate: methanol: ammonia: formic acid (7: 2: 0.2: 0.2, by volume) as a developing system with UV scanning for the developed bands at 235 nm. The Rf values for metformin, glipizide, sitagliptin, melamine and cyanoguanidine were 0.17, 0.84, 0.67, 0.47 and 0.75, respectively. Linear responses were observed in the ranges of 0.2-3, 0.07-1.5, 1.5-5, 0.8-4 and 0.4-2 μg/band with correlation coefficients of 0.9999, 0.9998, 0.9997, 0.9996 and 0.9998 for metformin, glipizide, sitagliptin, melamine and cyanoguanidine, respectively. The proposed method was validated as per ICH criteria with respect to linearity, accuracy, precision, specificity and robustness. The validated method was successfully applied for determination of the studied drugs in Janumet® and Engilor® tablets; also, the results were statistically compared to those obtained by the reported spectrophotometric method and no significant difference was found between them. This method permitted the accurate simultaneous determination of the studied drugs, indicating its ability to be used for routine quality control assays of these drugs.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2024-07-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1093/chromsci/bmad026\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1093/chromsci/bmad026","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
Ecofriendly Chromatographic Assay of Metformin Combinations; Content Uniformity Tests and Toxicity Profiling.
Accurate, sensitive and green HPTLC chromatographic method was proposed for simultaneous determination of metformin, glipizide and sitagliptin in the presence of metformin potential toxic impurities melamine and cyanoguanidine. The separation was completed on silica gel HPTLC F254 plates using a mixture of ethyl acetate: methanol: ammonia: formic acid (7: 2: 0.2: 0.2, by volume) as a developing system with UV scanning for the developed bands at 235 nm. The Rf values for metformin, glipizide, sitagliptin, melamine and cyanoguanidine were 0.17, 0.84, 0.67, 0.47 and 0.75, respectively. Linear responses were observed in the ranges of 0.2-3, 0.07-1.5, 1.5-5, 0.8-4 and 0.4-2 μg/band with correlation coefficients of 0.9999, 0.9998, 0.9997, 0.9996 and 0.9998 for metformin, glipizide, sitagliptin, melamine and cyanoguanidine, respectively. The proposed method was validated as per ICH criteria with respect to linearity, accuracy, precision, specificity and robustness. The validated method was successfully applied for determination of the studied drugs in Janumet® and Engilor® tablets; also, the results were statistically compared to those obtained by the reported spectrophotometric method and no significant difference was found between them. This method permitted the accurate simultaneous determination of the studied drugs, indicating its ability to be used for routine quality control assays of these drugs.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.