38. 氯己定漂洗后的血液污染对自蚀刻引物粘结托架粘结强度的影响——体外研究

Mymensingh medical journal : MMJ Pub Date : 2023-04-01
N Dubey, S Anjum, A Saxena, D Soni, S Marothiya, A Prakash, C Bharti
{"title":"38. 氯己定漂洗后的血液污染对自蚀刻引物粘结托架粘结强度的影响——体外研究","authors":"N Dubey,&nbsp;S Anjum,&nbsp;A Saxena,&nbsp;D Soni,&nbsp;S Marothiya,&nbsp;A Prakash,&nbsp;C Bharti","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The present invitro type of study has done to check the effect of blood contamination & chlorhexidine combination on the bond strength of brackets bonded with self-etch primer technique. The study consisted of ninety sound human upper premolars (extracted for orthodontic purpose) fixed in a self-cure acrylic block and segregated into three groups of 30 samples each. 0.022 slot metal MBT brackets (Gemini series-3M unitek) were bonded with self-etch primer using Transbond XT composite, CA, USA and light cure for 40 seconds) on clean buccal surface. Teeth were divided into 3 groups-Group A/Control group, Group B, Group C. A computer was used to record the force applied to debond the bonded bracket in the unit of Newton. The analysis of variance indicated that there were significant differences (F value = 6.891, p value=0.002) in bond strengths between the various groups tested. The highest value of shear bond strength occurred when chlorhexidine (Group C) was used to remove the blood contamination (mean=15.874 MPa). When bonding was done in ideal condition (Group A), shear bond strength obtained was slightly lower (mean=14.497 MPa) as compared to Group C. On the other hand, lowest shear bond strength among all three groups occurred when blood contamination (Group B) was removed with water (mean=11.059 MPa). Analysis of the study showed that shear bond strength of orthodontic brackets to enamel significantly decreased during bonding with self-etch primer in blood contamination condition. Self-etch primer displayed considerably superior performance with the use of chlorhexidine instead of water to wash the blood contamination.</p>","PeriodicalId":18959,"journal":{"name":"Mymensingh medical journal : MMJ","volume":"32 2","pages":"550-555"},"PeriodicalIF":0.0000,"publicationDate":"2023-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"38. Effect of Chlorhexidine Rinsed Blood Contamination on Bond Strength of Brackets Bonded with Self-etch Primer- An in Vitro Study.\",\"authors\":\"N Dubey,&nbsp;S Anjum,&nbsp;A Saxena,&nbsp;D Soni,&nbsp;S Marothiya,&nbsp;A Prakash,&nbsp;C Bharti\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The present invitro type of study has done to check the effect of blood contamination & chlorhexidine combination on the bond strength of brackets bonded with self-etch primer technique. The study consisted of ninety sound human upper premolars (extracted for orthodontic purpose) fixed in a self-cure acrylic block and segregated into three groups of 30 samples each. 0.022 slot metal MBT brackets (Gemini series-3M unitek) were bonded with self-etch primer using Transbond XT composite, CA, USA and light cure for 40 seconds) on clean buccal surface. Teeth were divided into 3 groups-Group A/Control group, Group B, Group C. A computer was used to record the force applied to debond the bonded bracket in the unit of Newton. The analysis of variance indicated that there were significant differences (F value = 6.891, p value=0.002) in bond strengths between the various groups tested. The highest value of shear bond strength occurred when chlorhexidine (Group C) was used to remove the blood contamination (mean=15.874 MPa). When bonding was done in ideal condition (Group A), shear bond strength obtained was slightly lower (mean=14.497 MPa) as compared to Group C. On the other hand, lowest shear bond strength among all three groups occurred when blood contamination (Group B) was removed with water (mean=11.059 MPa). Analysis of the study showed that shear bond strength of orthodontic brackets to enamel significantly decreased during bonding with self-etch primer in blood contamination condition. Self-etch primer displayed considerably superior performance with the use of chlorhexidine instead of water to wash the blood contamination.</p>\",\"PeriodicalId\":18959,\"journal\":{\"name\":\"Mymensingh medical journal : MMJ\",\"volume\":\"32 2\",\"pages\":\"550-555\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Mymensingh medical journal : MMJ\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Mymensingh medical journal : MMJ","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

采用自蚀刻底漆技术,研究了血液污染与氯己定联合对支架粘结强度的影响。该研究包括90颗健康的人类上颌前磨牙(用于正畸目的拔牙)固定在自固化丙烯酸块中,并分为三组,每组30个样本。将0.022槽型金属MBT支架(Gemini系列- 3m unitek)与自蚀刻处理剂(使用Transbond XT复合材料,CA, USA,光固化40秒)粘合在清洁的口腔表面。将牙分为3组:A组/对照组、B组、c组。用计算机以牛顿为单位记录对粘接托架的脱粘力。方差分析表明,各测试组之间的粘结强度存在显著差异(F值= 6.891,p值=0.002)。用氯己定(C组)去除血液污染时剪切结合强度最高(平均=15.874 MPa)。在理想状态下(A组)粘接时,获得的剪切粘接强度略低于c组(平均为14.497 MPa),而三组中剪切粘接强度最低的是用水去除血液污染(B组)时(平均为11.059 MPa)。研究分析表明,在血液污染条件下,使用自蚀底漆粘结正畸托槽时,正畸托槽与牙釉质的剪切结合强度明显降低。用氯己定代替水冲洗血液污染的自蚀刻底漆显示出相当优越的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
38. Effect of Chlorhexidine Rinsed Blood Contamination on Bond Strength of Brackets Bonded with Self-etch Primer- An in Vitro Study.

The present invitro type of study has done to check the effect of blood contamination & chlorhexidine combination on the bond strength of brackets bonded with self-etch primer technique. The study consisted of ninety sound human upper premolars (extracted for orthodontic purpose) fixed in a self-cure acrylic block and segregated into three groups of 30 samples each. 0.022 slot metal MBT brackets (Gemini series-3M unitek) were bonded with self-etch primer using Transbond XT composite, CA, USA and light cure for 40 seconds) on clean buccal surface. Teeth were divided into 3 groups-Group A/Control group, Group B, Group C. A computer was used to record the force applied to debond the bonded bracket in the unit of Newton. The analysis of variance indicated that there were significant differences (F value = 6.891, p value=0.002) in bond strengths between the various groups tested. The highest value of shear bond strength occurred when chlorhexidine (Group C) was used to remove the blood contamination (mean=15.874 MPa). When bonding was done in ideal condition (Group A), shear bond strength obtained was slightly lower (mean=14.497 MPa) as compared to Group C. On the other hand, lowest shear bond strength among all three groups occurred when blood contamination (Group B) was removed with water (mean=11.059 MPa). Analysis of the study showed that shear bond strength of orthodontic brackets to enamel significantly decreased during bonding with self-etch primer in blood contamination condition. Self-etch primer displayed considerably superior performance with the use of chlorhexidine instead of water to wash the blood contamination.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信