N Dubey, S Anjum, A Saxena, D Soni, S Marothiya, A Prakash, C Bharti
{"title":"38. 氯己定漂洗后的血液污染对自蚀刻引物粘结托架粘结强度的影响——体外研究","authors":"N Dubey, S Anjum, A Saxena, D Soni, S Marothiya, A Prakash, C Bharti","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The present invitro type of study has done to check the effect of blood contamination & chlorhexidine combination on the bond strength of brackets bonded with self-etch primer technique. The study consisted of ninety sound human upper premolars (extracted for orthodontic purpose) fixed in a self-cure acrylic block and segregated into three groups of 30 samples each. 0.022 slot metal MBT brackets (Gemini series-3M unitek) were bonded with self-etch primer using Transbond XT composite, CA, USA and light cure for 40 seconds) on clean buccal surface. Teeth were divided into 3 groups-Group A/Control group, Group B, Group C. A computer was used to record the force applied to debond the bonded bracket in the unit of Newton. The analysis of variance indicated that there were significant differences (F value = 6.891, p value=0.002) in bond strengths between the various groups tested. The highest value of shear bond strength occurred when chlorhexidine (Group C) was used to remove the blood contamination (mean=15.874 MPa). When bonding was done in ideal condition (Group A), shear bond strength obtained was slightly lower (mean=14.497 MPa) as compared to Group C. On the other hand, lowest shear bond strength among all three groups occurred when blood contamination (Group B) was removed with water (mean=11.059 MPa). Analysis of the study showed that shear bond strength of orthodontic brackets to enamel significantly decreased during bonding with self-etch primer in blood contamination condition. Self-etch primer displayed considerably superior performance with the use of chlorhexidine instead of water to wash the blood contamination.</p>","PeriodicalId":18959,"journal":{"name":"Mymensingh medical journal : MMJ","volume":"32 2","pages":"550-555"},"PeriodicalIF":0.0000,"publicationDate":"2023-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"38. Effect of Chlorhexidine Rinsed Blood Contamination on Bond Strength of Brackets Bonded with Self-etch Primer- An in Vitro Study.\",\"authors\":\"N Dubey, S Anjum, A Saxena, D Soni, S Marothiya, A Prakash, C Bharti\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The present invitro type of study has done to check the effect of blood contamination & chlorhexidine combination on the bond strength of brackets bonded with self-etch primer technique. The study consisted of ninety sound human upper premolars (extracted for orthodontic purpose) fixed in a self-cure acrylic block and segregated into three groups of 30 samples each. 0.022 slot metal MBT brackets (Gemini series-3M unitek) were bonded with self-etch primer using Transbond XT composite, CA, USA and light cure for 40 seconds) on clean buccal surface. Teeth were divided into 3 groups-Group A/Control group, Group B, Group C. A computer was used to record the force applied to debond the bonded bracket in the unit of Newton. The analysis of variance indicated that there were significant differences (F value = 6.891, p value=0.002) in bond strengths between the various groups tested. The highest value of shear bond strength occurred when chlorhexidine (Group C) was used to remove the blood contamination (mean=15.874 MPa). When bonding was done in ideal condition (Group A), shear bond strength obtained was slightly lower (mean=14.497 MPa) as compared to Group C. On the other hand, lowest shear bond strength among all three groups occurred when blood contamination (Group B) was removed with water (mean=11.059 MPa). Analysis of the study showed that shear bond strength of orthodontic brackets to enamel significantly decreased during bonding with self-etch primer in blood contamination condition. Self-etch primer displayed considerably superior performance with the use of chlorhexidine instead of water to wash the blood contamination.</p>\",\"PeriodicalId\":18959,\"journal\":{\"name\":\"Mymensingh medical journal : MMJ\",\"volume\":\"32 2\",\"pages\":\"550-555\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Mymensingh medical journal : MMJ\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Mymensingh medical journal : MMJ","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
38. Effect of Chlorhexidine Rinsed Blood Contamination on Bond Strength of Brackets Bonded with Self-etch Primer- An in Vitro Study.
The present invitro type of study has done to check the effect of blood contamination & chlorhexidine combination on the bond strength of brackets bonded with self-etch primer technique. The study consisted of ninety sound human upper premolars (extracted for orthodontic purpose) fixed in a self-cure acrylic block and segregated into three groups of 30 samples each. 0.022 slot metal MBT brackets (Gemini series-3M unitek) were bonded with self-etch primer using Transbond XT composite, CA, USA and light cure for 40 seconds) on clean buccal surface. Teeth were divided into 3 groups-Group A/Control group, Group B, Group C. A computer was used to record the force applied to debond the bonded bracket in the unit of Newton. The analysis of variance indicated that there were significant differences (F value = 6.891, p value=0.002) in bond strengths between the various groups tested. The highest value of shear bond strength occurred when chlorhexidine (Group C) was used to remove the blood contamination (mean=15.874 MPa). When bonding was done in ideal condition (Group A), shear bond strength obtained was slightly lower (mean=14.497 MPa) as compared to Group C. On the other hand, lowest shear bond strength among all three groups occurred when blood contamination (Group B) was removed with water (mean=11.059 MPa). Analysis of the study showed that shear bond strength of orthodontic brackets to enamel significantly decreased during bonding with self-etch primer in blood contamination condition. Self-etch primer displayed considerably superior performance with the use of chlorhexidine instead of water to wash the blood contamination.