Katarzyna Nowomiejska, Fadi Nasser, Agnieszka Brzozowska, Robert Rejdak, Eberhart Zrenner
{"title":"Farnsworth二分D-15面板试验的精细评估有助于区分最佳葡萄状黄斑营养不良和常染色体隐性营养不良。","authors":"Katarzyna Nowomiejska, Fadi Nasser, Agnieszka Brzozowska, Robert Rejdak, Eberhart Zrenner","doi":"10.1159/000528615","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>The colour vision in bestrophinopathies has not been assessed in detail so far. The aim of this study was to explore the extent to which distinct types of bestrophinopathies differ in regard to colour vision deficiencies using Farnsworth Dichotomous D-15 and Lanthony Desaturated D-15 panel tests.</p><p><strong>Methods: </strong>Both D-15 tests were performed in 52 eyes of 26 patients with Best vitelliform macular dystrophy (BVMD) and 10 eyes of 5 patients with autosomal recessive bestrophinopathy (ARB). Two methods were used for a quantitative assessment of the colour vision deficiencies: moment of inertia method and Bowman method. The following parameters were calculated: confusion angle, confusion index (C-index), selectivity index (S-index), total error score (TES), and colour confusion index (CCI).</p><p><strong>Results: </strong>The median value of confusion angle for all stages of BVMD fell into a narrow range around 62, indicating normal results. The median confusion angle value was 57 in ARB patients within a very wide range down to -82, indicating non-specific deficits. These differences were statistically significant. Significantly abnormal C-index and CCI values were found only in ARB patients, being 2.0 and 1.49, respectively. The majority of parameters of D-15 tests were independent of the visual acuity in both bestrophinopathies.</p><p><strong>Conclusions: </strong>Elaborate evaluation of the D-15 panel tests might help establish a differential diagnosis between different bestrophinopathies, as the pattern of the colour vision loss is different between BVMD and ARB. The quantitative parameters of colour vision tests in bestrophinopathies are independent of the visual acuity.</p>","PeriodicalId":19662,"journal":{"name":"Ophthalmic Research","volume":" ","pages":"481-488"},"PeriodicalIF":2.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11149457/pdf/","citationCount":"0","resultStr":"{\"title\":\"Elaborate Evaluation of Farnsworth Dichotomous D-15 Panel Test Can Help Differentiate between Best Vitelliform Macular Dystrophy and Autosomal Recessive Bestrophinopathy.\",\"authors\":\"Katarzyna Nowomiejska, Fadi Nasser, Agnieszka Brzozowska, Robert Rejdak, Eberhart Zrenner\",\"doi\":\"10.1159/000528615\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>The colour vision in bestrophinopathies has not been assessed in detail so far. The aim of this study was to explore the extent to which distinct types of bestrophinopathies differ in regard to colour vision deficiencies using Farnsworth Dichotomous D-15 and Lanthony Desaturated D-15 panel tests.</p><p><strong>Methods: </strong>Both D-15 tests were performed in 52 eyes of 26 patients with Best vitelliform macular dystrophy (BVMD) and 10 eyes of 5 patients with autosomal recessive bestrophinopathy (ARB). Two methods were used for a quantitative assessment of the colour vision deficiencies: moment of inertia method and Bowman method. The following parameters were calculated: confusion angle, confusion index (C-index), selectivity index (S-index), total error score (TES), and colour confusion index (CCI).</p><p><strong>Results: </strong>The median value of confusion angle for all stages of BVMD fell into a narrow range around 62, indicating normal results. The median confusion angle value was 57 in ARB patients within a very wide range down to -82, indicating non-specific deficits. These differences were statistically significant. Significantly abnormal C-index and CCI values were found only in ARB patients, being 2.0 and 1.49, respectively. The majority of parameters of D-15 tests were independent of the visual acuity in both bestrophinopathies.</p><p><strong>Conclusions: </strong>Elaborate evaluation of the D-15 panel tests might help establish a differential diagnosis between different bestrophinopathies, as the pattern of the colour vision loss is different between BVMD and ARB. The quantitative parameters of colour vision tests in bestrophinopathies are independent of the visual acuity.</p>\",\"PeriodicalId\":19662,\"journal\":{\"name\":\"Ophthalmic Research\",\"volume\":\" \",\"pages\":\"481-488\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11149457/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ophthalmic Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1159/000528615\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/1/12 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ophthalmic Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1159/000528615","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/1/12 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
Elaborate Evaluation of Farnsworth Dichotomous D-15 Panel Test Can Help Differentiate between Best Vitelliform Macular Dystrophy and Autosomal Recessive Bestrophinopathy.
Introduction: The colour vision in bestrophinopathies has not been assessed in detail so far. The aim of this study was to explore the extent to which distinct types of bestrophinopathies differ in regard to colour vision deficiencies using Farnsworth Dichotomous D-15 and Lanthony Desaturated D-15 panel tests.
Methods: Both D-15 tests were performed in 52 eyes of 26 patients with Best vitelliform macular dystrophy (BVMD) and 10 eyes of 5 patients with autosomal recessive bestrophinopathy (ARB). Two methods were used for a quantitative assessment of the colour vision deficiencies: moment of inertia method and Bowman method. The following parameters were calculated: confusion angle, confusion index (C-index), selectivity index (S-index), total error score (TES), and colour confusion index (CCI).
Results: The median value of confusion angle for all stages of BVMD fell into a narrow range around 62, indicating normal results. The median confusion angle value was 57 in ARB patients within a very wide range down to -82, indicating non-specific deficits. These differences were statistically significant. Significantly abnormal C-index and CCI values were found only in ARB patients, being 2.0 and 1.49, respectively. The majority of parameters of D-15 tests were independent of the visual acuity in both bestrophinopathies.
Conclusions: Elaborate evaluation of the D-15 panel tests might help establish a differential diagnosis between different bestrophinopathies, as the pattern of the colour vision loss is different between BVMD and ARB. The quantitative parameters of colour vision tests in bestrophinopathies are independent of the visual acuity.
期刊介绍:
''Ophthalmic Research'' features original papers and reviews reporting on translational and clinical studies. Authors from throughout the world cover research topics on every field in connection with physical, physiologic, pharmacological, biochemical and molecular biological aspects of ophthalmology. This journal also aims to provide a record of international clinical research for both researchers and clinicians in ophthalmology. Finally, the transfer of information from fundamental research to clinical research and clinical practice is particularly welcome.