刚性90°、刚性70°和柔性喉镜检查时声门闭合和前联合可视性的差异。

IF 1.1 4区 医学 Q3 AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY
Folia Phoniatrica et Logopaedica Pub Date : 2023-01-01 Epub Date: 2023-03-31 DOI:10.1159/000530454
Roland Paulus, Matthias Leonhard, Guan-Yuh Ho, Annabella Kurz, Berit Schneider-Stickler
{"title":"刚性90°、刚性70°和柔性喉镜检查时声门闭合和前联合可视性的差异。","authors":"Roland Paulus,&nbsp;Matthias Leonhard,&nbsp;Guan-Yuh Ho,&nbsp;Annabella Kurz,&nbsp;Berit Schneider-Stickler","doi":"10.1159/000530454","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>The conventional rigid-90° and rigid-70° laryngostroboscopy has been so far considered the gold standard in assessing the vibratory behavior of the vocal folds and the glottal closure configuration during phonation. Meanwhile, this rigid laryngostroboscopy is more and more replaced by flexible chip-on-tip systems. The aim of this study was to evaluate the influence of these different endoscopic techniques on glottal closure configuration and on visibility of the complete focal fold length including anterior commissure during phonation.</p><p><strong>Methods: </strong>Twenty-one euphonic subjects were enrolled (mean age 34.6 ± 9.5; m = 10, f = 11). They were examined with the three laryngoscopic techniques (conventional rigid-90°, rigid-70°, and flexible chip-on-tip laryngoscopy during low and high voice pitch with soft and loud voice intensity). For evaluating the degree of glottal closure, a modified classification of Södersten et al. was applied and the visibility of the anterior commissure was evaluated. The correlation of the three endoscopic techniques was assessed with Cohen and Fleiss' kappa.</p><p><strong>Results: </strong>In even low loud phonation, the rigid-90° and rigid-70° endoscopies revealed a complete closure of the glottis in only 47.6% of subjects but with flexible endoscopy in 81%. The complete vocal fold length with anterior commissure was best visible with flexible endoscopy in 90.5% in low-soft and high-soft phonation. The rigid-90° endoscopy showed a slight agreement in comparison with the flexible endoscopy in regard to the types of vocal fold closure with a Cohen's kappa coefficient k = 0.199. The rigid-90° endoscopy showed an almost perfect agreement with k = 0.84 when compared to the rigid-70° endoscopy. The flexible endoscopy compared to the rigid-70° endoscopy showed a fair agreement with k = 0.346.</p><p><strong>Conclusion: </strong>We found mainly corresponding results in both rigid-90° and rigid-70° endoscopic techniques which can be explained by the same transoral approach with the tongue pulled out, whereas the flexible transnasal endoscopy mainly gives a better view on the anterior commissure. The influence of transorally or transnasally guided endoscopic techniques needs to be considered in interpretation of laryngostroboscopic parameters like vocal fold closure and supraglottal hyperactivity.</p>","PeriodicalId":12114,"journal":{"name":"Folia Phoniatrica et Logopaedica","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10614229/pdf/","citationCount":"1","resultStr":"{\"title\":\"Differences in Glottal Closure and Visibility of the Anterior Commissure during Rigid-90°, Rigid-70°, and Flexible Laryngostroboscopy.\",\"authors\":\"Roland Paulus,&nbsp;Matthias Leonhard,&nbsp;Guan-Yuh Ho,&nbsp;Annabella Kurz,&nbsp;Berit Schneider-Stickler\",\"doi\":\"10.1159/000530454\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>The conventional rigid-90° and rigid-70° laryngostroboscopy has been so far considered the gold standard in assessing the vibratory behavior of the vocal folds and the glottal closure configuration during phonation. Meanwhile, this rigid laryngostroboscopy is more and more replaced by flexible chip-on-tip systems. The aim of this study was to evaluate the influence of these different endoscopic techniques on glottal closure configuration and on visibility of the complete focal fold length including anterior commissure during phonation.</p><p><strong>Methods: </strong>Twenty-one euphonic subjects were enrolled (mean age 34.6 ± 9.5; m = 10, f = 11). They were examined with the three laryngoscopic techniques (conventional rigid-90°, rigid-70°, and flexible chip-on-tip laryngoscopy during low and high voice pitch with soft and loud voice intensity). For evaluating the degree of glottal closure, a modified classification of Södersten et al. was applied and the visibility of the anterior commissure was evaluated. The correlation of the three endoscopic techniques was assessed with Cohen and Fleiss' kappa.</p><p><strong>Results: </strong>In even low loud phonation, the rigid-90° and rigid-70° endoscopies revealed a complete closure of the glottis in only 47.6% of subjects but with flexible endoscopy in 81%. The complete vocal fold length with anterior commissure was best visible with flexible endoscopy in 90.5% in low-soft and high-soft phonation. The rigid-90° endoscopy showed a slight agreement in comparison with the flexible endoscopy in regard to the types of vocal fold closure with a Cohen's kappa coefficient k = 0.199. The rigid-90° endoscopy showed an almost perfect agreement with k = 0.84 when compared to the rigid-70° endoscopy. The flexible endoscopy compared to the rigid-70° endoscopy showed a fair agreement with k = 0.346.</p><p><strong>Conclusion: </strong>We found mainly corresponding results in both rigid-90° and rigid-70° endoscopic techniques which can be explained by the same transoral approach with the tongue pulled out, whereas the flexible transnasal endoscopy mainly gives a better view on the anterior commissure. The influence of transorally or transnasally guided endoscopic techniques needs to be considered in interpretation of laryngostroboscopic parameters like vocal fold closure and supraglottal hyperactivity.</p>\",\"PeriodicalId\":12114,\"journal\":{\"name\":\"Folia Phoniatrica et Logopaedica\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10614229/pdf/\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Folia Phoniatrica et Logopaedica\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1159/000530454\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/3/31 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Folia Phoniatrica et Logopaedica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1159/000530454","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/3/31 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY","Score":null,"Total":0}
引用次数: 1

摘要

引言:到目前为止,传统的90°和70°喉镜检查被认为是评估发声过程中声带振动行为和声门闭合结构的金标准。同时,这种刚性喉镜越来越多地被柔性尖端芯片系统所取代。本研究的目的是评估这些不同的内镜技术对声门闭合结构和发音过程中包括前连合在内的完整局灶折叠长度的可见性的影响。方法:入选21名委婉语受试者(平均年龄34.6±9.5;m=10,f=11)。他们用三种喉镜技术(传统的刚性-90°、刚性-70°和柔性芯片喉镜,在声音强度柔和和响亮的低音和高音中进行检查)进行检查。为了评估声门闭合程度,采用了Södersten等人的改良分类,并评估了前连合的可见性。Cohen和Fleiss’kappa评估了三种内窥镜技术的相关性。结果:即使在低音量发音中,90°和70°的硬内镜检查显示,只有47.6%的受试者声门完全闭合,但81%的受试人的软内镜检查显示声门完全闭合。柔性内窥镜检查显示,在低柔和高柔发音中,带前连合的完整声带长度最明显,占90.5%。与柔性内窥镜相比,刚性90°内窥镜在声带闭合类型方面略有一致,Cohen’s kappa系数k=0.199。与刚性70°内镜相比,刚性90°内镜显示出几乎完美的一致性,k=0.84。柔性内窥镜与刚性70°内窥镜相比显示出相当的一致性,k=0.346。结论:我们在刚性90°和刚性70°的内窥镜技术中发现了主要的对应结果,这可以用拔出舌头的同一经口入路来解释,而柔性经鼻内窥镜主要能更好地观察前连合。在解释喉镜参数(如声带闭合和声门上多动)时,需要考虑经口或经鼻引导的内窥镜技术的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Differences in Glottal Closure and Visibility of the Anterior Commissure during Rigid-90°, Rigid-70°, and Flexible Laryngostroboscopy.

Differences in Glottal Closure and Visibility of the Anterior Commissure during Rigid-90°, Rigid-70°, and Flexible Laryngostroboscopy.

Differences in Glottal Closure and Visibility of the Anterior Commissure during Rigid-90°, Rigid-70°, and Flexible Laryngostroboscopy.

Introduction: The conventional rigid-90° and rigid-70° laryngostroboscopy has been so far considered the gold standard in assessing the vibratory behavior of the vocal folds and the glottal closure configuration during phonation. Meanwhile, this rigid laryngostroboscopy is more and more replaced by flexible chip-on-tip systems. The aim of this study was to evaluate the influence of these different endoscopic techniques on glottal closure configuration and on visibility of the complete focal fold length including anterior commissure during phonation.

Methods: Twenty-one euphonic subjects were enrolled (mean age 34.6 ± 9.5; m = 10, f = 11). They were examined with the three laryngoscopic techniques (conventional rigid-90°, rigid-70°, and flexible chip-on-tip laryngoscopy during low and high voice pitch with soft and loud voice intensity). For evaluating the degree of glottal closure, a modified classification of Södersten et al. was applied and the visibility of the anterior commissure was evaluated. The correlation of the three endoscopic techniques was assessed with Cohen and Fleiss' kappa.

Results: In even low loud phonation, the rigid-90° and rigid-70° endoscopies revealed a complete closure of the glottis in only 47.6% of subjects but with flexible endoscopy in 81%. The complete vocal fold length with anterior commissure was best visible with flexible endoscopy in 90.5% in low-soft and high-soft phonation. The rigid-90° endoscopy showed a slight agreement in comparison with the flexible endoscopy in regard to the types of vocal fold closure with a Cohen's kappa coefficient k = 0.199. The rigid-90° endoscopy showed an almost perfect agreement with k = 0.84 when compared to the rigid-70° endoscopy. The flexible endoscopy compared to the rigid-70° endoscopy showed a fair agreement with k = 0.346.

Conclusion: We found mainly corresponding results in both rigid-90° and rigid-70° endoscopic techniques which can be explained by the same transoral approach with the tongue pulled out, whereas the flexible transnasal endoscopy mainly gives a better view on the anterior commissure. The influence of transorally or transnasally guided endoscopic techniques needs to be considered in interpretation of laryngostroboscopic parameters like vocal fold closure and supraglottal hyperactivity.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Folia Phoniatrica et Logopaedica
Folia Phoniatrica et Logopaedica AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY-OTORHINOLARYNGOLOGY
CiteScore
2.30
自引率
10.00%
发文量
28
审稿时长
>12 weeks
期刊介绍: Published since 1947, ''Folia Phoniatrica et Logopaedica'' provides a forum for international research on the anatomy, physiology, and pathology of structures of the speech, language, and hearing mechanisms. Original papers published in this journal report new findings on basic function, assessment, management, and test development in communication sciences and disorders, as well as experiments designed to test specific theories of speech, language, and hearing function. Review papers of high quality are also welcomed.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信