多输入血流模型的无影非线性磁共振成像校准。

Q2 Medicine
Tomoki Saka, Toshiyuki Gotoh, Seiichiro Kagei, Tae Iwasawa, Rogerio Y Takimoto, Marcos S G Tsuzuki
{"title":"多输入血流模型的无影非线性磁共振成像校准。","authors":"Tomoki Saka,&nbsp;Toshiyuki Gotoh,&nbsp;Seiichiro Kagei,&nbsp;Tae Iwasawa,&nbsp;Rogerio Y Takimoto,&nbsp;Marcos S G Tsuzuki","doi":"10.1097/RMR.0000000000000302","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Previous work used phantoms to calibrate the nonlinear relationship between the gadolinium contrast concentration and the intensity of the magnetic resonance imaging signal. This work proposes a new nonlinear calibration procedure without phantoms and considers the variation of contrast agent mass minimum combined with the multiple input blood flow system. This also proposes a new single-input method with meaningful variables that is not influenced by reperfusion or noise generated by aliasing. The reperfusion in the lung is usually neglected and is not considered by the indicator dilution method. However, in cases of lung cancer, reperfusion cannot be neglected. A new multiple input method is formulated, and the contribution of the pulmonary artery and bronchial artery to lung perfusion can be considered and evaluated separately.</p><p><strong>Methods: </strong>The calibration procedure applies the minimum variation of contrast agent mass in 3 different regions: (1) pulmonary artery, (2) left atrium, and (3) aorta. It was compared with four dimensional computerized tomography with iodine, which has a very high proportional relationship between contrast agent concentration and signal intensity.</p><p><strong>Results: </strong>Nonlinear calibration was performed without phantoms, and it is in the range of phantom calibration. It successfully separated the contributions of the pulmonary and bronchial arteries. The proposed multiple input method was verified in 6 subjects with lung cancer, and perfusion from the bronchial artery, rich in oxygen, was identified as very high in the cancer region.</p><p><strong>Conclusions: </strong>Nonlinear calibration of the contrast agent without phantoms is possible. Separate contributions of the pulmonary artery and aorta can be determined.</p>","PeriodicalId":39381,"journal":{"name":"Topics in Magnetic Resonance Imaging","volume":"32 1","pages":"5-13"},"PeriodicalIF":0.0000,"publicationDate":"2023-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Phantom-Less Nonlinear Magnetic Resonance Imaging Calibration With Multiple Input Blood Flow Model.\",\"authors\":\"Tomoki Saka,&nbsp;Toshiyuki Gotoh,&nbsp;Seiichiro Kagei,&nbsp;Tae Iwasawa,&nbsp;Rogerio Y Takimoto,&nbsp;Marcos S G Tsuzuki\",\"doi\":\"10.1097/RMR.0000000000000302\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Previous work used phantoms to calibrate the nonlinear relationship between the gadolinium contrast concentration and the intensity of the magnetic resonance imaging signal. This work proposes a new nonlinear calibration procedure without phantoms and considers the variation of contrast agent mass minimum combined with the multiple input blood flow system. This also proposes a new single-input method with meaningful variables that is not influenced by reperfusion or noise generated by aliasing. The reperfusion in the lung is usually neglected and is not considered by the indicator dilution method. However, in cases of lung cancer, reperfusion cannot be neglected. A new multiple input method is formulated, and the contribution of the pulmonary artery and bronchial artery to lung perfusion can be considered and evaluated separately.</p><p><strong>Methods: </strong>The calibration procedure applies the minimum variation of contrast agent mass in 3 different regions: (1) pulmonary artery, (2) left atrium, and (3) aorta. It was compared with four dimensional computerized tomography with iodine, which has a very high proportional relationship between contrast agent concentration and signal intensity.</p><p><strong>Results: </strong>Nonlinear calibration was performed without phantoms, and it is in the range of phantom calibration. It successfully separated the contributions of the pulmonary and bronchial arteries. The proposed multiple input method was verified in 6 subjects with lung cancer, and perfusion from the bronchial artery, rich in oxygen, was identified as very high in the cancer region.</p><p><strong>Conclusions: </strong>Nonlinear calibration of the contrast agent without phantoms is possible. Separate contributions of the pulmonary artery and aorta can be determined.</p>\",\"PeriodicalId\":39381,\"journal\":{\"name\":\"Topics in Magnetic Resonance Imaging\",\"volume\":\"32 1\",\"pages\":\"5-13\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Topics in Magnetic Resonance Imaging\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1097/RMR.0000000000000302\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Topics in Magnetic Resonance Imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/RMR.0000000000000302","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

目的:以往的研究工作是利用幻影来校准钆造影剂浓度与磁共振成像信号强度之间的非线性关系。本文提出了一种新的非线性校正方法,并结合多输入血流系统,考虑了造影剂质量最小值的变化。这也提出了一种新的单输入方法,具有不受再灌注或混叠产生的噪声影响的有意义变量。肺的再灌注常被忽略,指标稀释法未考虑再灌注。然而,在肺癌病例中,再灌注是不可忽视的。提出了一种新的多重输入法,可以分别考虑和评价肺动脉和支气管动脉对肺灌注的贡献。方法:校准程序应用对比剂质量在3个不同区域的最小变化:(1)肺动脉,(2)左心房,(3)主动脉。它与碘的四维计算机断层扫描进行了比较,对比剂浓度与信号强度之间有很高的比例关系。结果:非线性定标无幻像,在幻像定标范围内。它成功地分离了肺动脉和支气管动脉的贡献。本文提出的多重输入法在6例肺癌患者身上进行了验证,发现肺癌区域的支气管动脉灌注量非常高,且富含氧气。结论:非线性定标造影剂无影是可行的。可以确定肺动脉和主动脉的单独作用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Phantom-Less Nonlinear Magnetic Resonance Imaging Calibration With Multiple Input Blood Flow Model.

Purpose: Previous work used phantoms to calibrate the nonlinear relationship between the gadolinium contrast concentration and the intensity of the magnetic resonance imaging signal. This work proposes a new nonlinear calibration procedure without phantoms and considers the variation of contrast agent mass minimum combined with the multiple input blood flow system. This also proposes a new single-input method with meaningful variables that is not influenced by reperfusion or noise generated by aliasing. The reperfusion in the lung is usually neglected and is not considered by the indicator dilution method. However, in cases of lung cancer, reperfusion cannot be neglected. A new multiple input method is formulated, and the contribution of the pulmonary artery and bronchial artery to lung perfusion can be considered and evaluated separately.

Methods: The calibration procedure applies the minimum variation of contrast agent mass in 3 different regions: (1) pulmonary artery, (2) left atrium, and (3) aorta. It was compared with four dimensional computerized tomography with iodine, which has a very high proportional relationship between contrast agent concentration and signal intensity.

Results: Nonlinear calibration was performed without phantoms, and it is in the range of phantom calibration. It successfully separated the contributions of the pulmonary and bronchial arteries. The proposed multiple input method was verified in 6 subjects with lung cancer, and perfusion from the bronchial artery, rich in oxygen, was identified as very high in the cancer region.

Conclusions: Nonlinear calibration of the contrast agent without phantoms is possible. Separate contributions of the pulmonary artery and aorta can be determined.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Topics in Magnetic Resonance Imaging
Topics in Magnetic Resonance Imaging Medicine-Medicine (all)
CiteScore
5.50
自引率
0.00%
发文量
24
期刊介绍: Topics in Magnetic Resonance Imaging is a leading information resource for professionals in the MRI community. This publication supplies authoritative, up-to-the-minute coverage of technical advances in this evolving field as well as practical, hands-on guidance from leading experts. Six times a year, TMRI focuses on a single timely topic of interest to radiologists. These topical issues present a variety of perspectives from top radiological authorities to provide an in-depth understanding of how MRI is being used in each area.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信