{"title":"197au在30kev和64kev中子能量下的(n, γ)截面","authors":"W. Pönitz","doi":"10.1016/0368-3230(66)90117-0","DOIUrl":null,"url":null,"abstract":"<div><p>The neutron capture cross section of <sup>197</sup>Au was measured at 30 and 64 keV neutron energy using the activation method. Two different methods were used at 30 keV for the absolute neutron flux determination. The results are σ<sub>n,γ</sub><sup>Au</sup> (30 keV) = (0600 ± 0·009) barn and σ<sub>n,γ</sub><sup>Au</sup> (64 keV) = (0·357 ± 0·009) barn.</p></div>","PeriodicalId":100815,"journal":{"name":"Journal of Nuclear Energy. Parts A/B. Reactor Science and Technology","volume":"20 10","pages":"Pages 825-834"},"PeriodicalIF":0.0000,"publicationDate":"1966-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0368-3230(66)90117-0","citationCount":"8","resultStr":"{\"title\":\"The (n, γ) cross section of 197au at 30 and 64 keV neutron energy\",\"authors\":\"W. Pönitz\",\"doi\":\"10.1016/0368-3230(66)90117-0\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The neutron capture cross section of <sup>197</sup>Au was measured at 30 and 64 keV neutron energy using the activation method. Two different methods were used at 30 keV for the absolute neutron flux determination. The results are σ<sub>n,γ</sub><sup>Au</sup> (30 keV) = (0600 ± 0·009) barn and σ<sub>n,γ</sub><sup>Au</sup> (64 keV) = (0·357 ± 0·009) barn.</p></div>\",\"PeriodicalId\":100815,\"journal\":{\"name\":\"Journal of Nuclear Energy. Parts A/B. Reactor Science and Technology\",\"volume\":\"20 10\",\"pages\":\"Pages 825-834\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1966-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/0368-3230(66)90117-0\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Nuclear Energy. Parts A/B. Reactor Science and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/0368323066901170\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Nuclear Energy. Parts A/B. Reactor Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/0368323066901170","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The (n, γ) cross section of 197au at 30 and 64 keV neutron energy
The neutron capture cross section of 197Au was measured at 30 and 64 keV neutron energy using the activation method. Two different methods were used at 30 keV for the absolute neutron flux determination. The results are σn,γAu (30 keV) = (0600 ± 0·009) barn and σn,γAu (64 keV) = (0·357 ± 0·009) barn.