{"title":"一种简单、安全的切口下皮质抽吸的双手技术。","authors":"T. Sakamoto, K. Shiraki, Kohji Inoue, N. Yanagihara, S. Ataka, Kaori Kurita","doi":"10.3928/1542-8877-20020701-18","DOIUrl":null,"url":null,"abstract":"We developed a bimanual manipulation technique to facilitate the removal of the subincisional lens cortex in small-incision phacoemulsification cataract surgery. A separate aspiration handpiece, not connected to an aspiration tube, is passed into the anterior chamber through a side-port corneal incision. Under irrigation with a standard infusion/aspiration (I/A) handpiece through a tunnel incision, the cortex is stripped off with the separate handpiece and removed with the I/A handpiece. In 227 eyes, subincisional cortex removal and subsequent capsule polishing was performed safely with the separate handpiece. Rupture of the posterior lens capsule occurred in 3 high-risk eyes.","PeriodicalId":19509,"journal":{"name":"Ophthalmic surgery and lasers","volume":"16 1","pages":"337-9"},"PeriodicalIF":0.0000,"publicationDate":"2002-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"A simple, safe bimanual technique for subincisional cortex aspiration.\",\"authors\":\"T. Sakamoto, K. Shiraki, Kohji Inoue, N. Yanagihara, S. Ataka, Kaori Kurita\",\"doi\":\"10.3928/1542-8877-20020701-18\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We developed a bimanual manipulation technique to facilitate the removal of the subincisional lens cortex in small-incision phacoemulsification cataract surgery. A separate aspiration handpiece, not connected to an aspiration tube, is passed into the anterior chamber through a side-port corneal incision. Under irrigation with a standard infusion/aspiration (I/A) handpiece through a tunnel incision, the cortex is stripped off with the separate handpiece and removed with the I/A handpiece. In 227 eyes, subincisional cortex removal and subsequent capsule polishing was performed safely with the separate handpiece. Rupture of the posterior lens capsule occurred in 3 high-risk eyes.\",\"PeriodicalId\":19509,\"journal\":{\"name\":\"Ophthalmic surgery and lasers\",\"volume\":\"16 1\",\"pages\":\"337-9\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ophthalmic surgery and lasers\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3928/1542-8877-20020701-18\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ophthalmic surgery and lasers","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3928/1542-8877-20020701-18","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A simple, safe bimanual technique for subincisional cortex aspiration.
We developed a bimanual manipulation technique to facilitate the removal of the subincisional lens cortex in small-incision phacoemulsification cataract surgery. A separate aspiration handpiece, not connected to an aspiration tube, is passed into the anterior chamber through a side-port corneal incision. Under irrigation with a standard infusion/aspiration (I/A) handpiece through a tunnel incision, the cortex is stripped off with the separate handpiece and removed with the I/A handpiece. In 227 eyes, subincisional cortex removal and subsequent capsule polishing was performed safely with the separate handpiece. Rupture of the posterior lens capsule occurred in 3 high-risk eyes.