{"title":"一种基于电阻抗测量系统的两相流浓度和流速标定实验装置","authors":"Jiacheng Wu, Shihong Yue, Haitao Ma","doi":"10.1109/I2MTC50364.2021.9460020","DOIUrl":null,"url":null,"abstract":"In dredging project, the $\\gamma$-ray based source densitometer is widely used to measure the concentration in solid-liquid two-phase flow, whereas it is radiant, polluted, and inaccurate. Recently, electric densitometers based on Electric Impedance Tomography(EIT) technology has developed to replace the $\\gamma$-ray source densitometer. However, the calibration and velocity of electrical densitometer is very difficult since complex working conditions cannot be uniformly tested and reconstructed. In this paper, a simple and effective device is designed to calibrate the results of the electrical densitometer. Experiments show that the device can reconstruct typical working conditions in dredging projects and accomplish quantitative analysis.","PeriodicalId":6772,"journal":{"name":"2021 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)","volume":"86 12","pages":"1-5"},"PeriodicalIF":0.0000,"publicationDate":"2021-05-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"An experimental device for calibration of concentration and velocity of two-phase flow based on electrical impedance measurement system\",\"authors\":\"Jiacheng Wu, Shihong Yue, Haitao Ma\",\"doi\":\"10.1109/I2MTC50364.2021.9460020\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In dredging project, the $\\\\gamma$-ray based source densitometer is widely used to measure the concentration in solid-liquid two-phase flow, whereas it is radiant, polluted, and inaccurate. Recently, electric densitometers based on Electric Impedance Tomography(EIT) technology has developed to replace the $\\\\gamma$-ray source densitometer. However, the calibration and velocity of electrical densitometer is very difficult since complex working conditions cannot be uniformly tested and reconstructed. In this paper, a simple and effective device is designed to calibrate the results of the electrical densitometer. Experiments show that the device can reconstruct typical working conditions in dredging projects and accomplish quantitative analysis.\",\"PeriodicalId\":6772,\"journal\":{\"name\":\"2021 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)\",\"volume\":\"86 12\",\"pages\":\"1-5\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-05-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/I2MTC50364.2021.9460020\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/I2MTC50364.2021.9460020","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

在疏浚工程中,基于伽马射线的源密度计被广泛用于固液两相流浓度测量,但它存在辐射、污染和不准确的问题。近年来,基于电阻抗层析成像(EIT)技术的电密度计已经发展起来,以取代伽马射线源密度计。然而,由于复杂的工作条件不能统一测试和重建,电密度计的校准和速度是非常困难的。本文设计了一种简单有效的装置来校准电密度计的测量结果。实验结果表明,该装置能够模拟疏浚工程的典型工况,并能完成定量分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An experimental device for calibration of concentration and velocity of two-phase flow based on electrical impedance measurement system
In dredging project, the $\gamma$-ray based source densitometer is widely used to measure the concentration in solid-liquid two-phase flow, whereas it is radiant, polluted, and inaccurate. Recently, electric densitometers based on Electric Impedance Tomography(EIT) technology has developed to replace the $\gamma$-ray source densitometer. However, the calibration and velocity of electrical densitometer is very difficult since complex working conditions cannot be uniformly tested and reconstructed. In this paper, a simple and effective device is designed to calibrate the results of the electrical densitometer. Experiments show that the device can reconstruct typical working conditions in dredging projects and accomplish quantitative analysis.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信