电化学免疫传感器灵敏测定尿液中TGF β1

E. Sánchez-Tirado, A. González-Cortés, P. Yánez-Sedeño, J.M. Pingarrón
{"title":"电化学免疫传感器灵敏测定尿液中TGF β1","authors":"E. Sánchez-Tirado,&nbsp;A. González-Cortés,&nbsp;P. Yánez-Sedeño,&nbsp;J.M. Pingarrón","doi":"10.1016/j.protcy.2017.04.035","DOIUrl":null,"url":null,"abstract":"<div><p>The first amperometric immunosensor for the quantification of TGF–<em>β</em>1 is described in this work. The immunosensor design involves disposable devices using carboxylic acid–functionalized magnetic microparticles supported onto screen–printed carbon electrodes and covalent immobilization of the specific antibody for TGF–<em>β</em>1 using Mix&amp;Go<sup>TM</sup> polymer. A sandwich–type immunoassay was performed using peroxidase–labeled streptavidin (Poly–HRP–Strept) polymer for signal amplification. The calibration plot allowed a range of linearity extending between 15 and 3000 pg/mL TGF–<em>β</em>1 (LOD 10 pg/mL). The usefulness of the immunosensor was evaluated by analyzing spiked urine at different pg/mL concentration levels.</p></div>","PeriodicalId":101042,"journal":{"name":"Procedia Technology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2017-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.protcy.2017.04.035","citationCount":"3","resultStr":"{\"title\":\"Electrochemical Immunosensor for Sensitive Determination of TGF β1 in Urine\",\"authors\":\"E. Sánchez-Tirado,&nbsp;A. González-Cortés,&nbsp;P. Yánez-Sedeño,&nbsp;J.M. Pingarrón\",\"doi\":\"10.1016/j.protcy.2017.04.035\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The first amperometric immunosensor for the quantification of TGF–<em>β</em>1 is described in this work. The immunosensor design involves disposable devices using carboxylic acid–functionalized magnetic microparticles supported onto screen–printed carbon electrodes and covalent immobilization of the specific antibody for TGF–<em>β</em>1 using Mix&amp;Go<sup>TM</sup> polymer. A sandwich–type immunoassay was performed using peroxidase–labeled streptavidin (Poly–HRP–Strept) polymer for signal amplification. The calibration plot allowed a range of linearity extending between 15 and 3000 pg/mL TGF–<em>β</em>1 (LOD 10 pg/mL). The usefulness of the immunosensor was evaluated by analyzing spiked urine at different pg/mL concentration levels.</p></div>\",\"PeriodicalId\":101042,\"journal\":{\"name\":\"Procedia Technology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/j.protcy.2017.04.035\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Procedia Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2212017317300361\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Procedia Technology","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2212017317300361","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

本文描述了第一种用于定量TGF -β1的安培免疫传感器。免疫传感器的设计包括使用羧酸功能化的磁性微粒支撑在丝网印刷的碳电极上的一次性装置,以及使用Mix&GoTM聚合物将TGF -β1特异性抗体共价固定。使用过氧化物酶标记的链亲和素(Poly-HRP-Strept)聚合物进行三明治式免疫分析,用于信号放大。校准图允许线性范围在15至3000 pg/mL之间扩展TGF -β1 (LOD为10 pg/mL)。通过分析不同pg/mL浓度水平的加标尿液来评估免疫传感器的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Electrochemical Immunosensor for Sensitive Determination of TGF β1 in Urine

The first amperometric immunosensor for the quantification of TGF–β1 is described in this work. The immunosensor design involves disposable devices using carboxylic acid–functionalized magnetic microparticles supported onto screen–printed carbon electrodes and covalent immobilization of the specific antibody for TGF–β1 using Mix&GoTM polymer. A sandwich–type immunoassay was performed using peroxidase–labeled streptavidin (Poly–HRP–Strept) polymer for signal amplification. The calibration plot allowed a range of linearity extending between 15 and 3000 pg/mL TGF–β1 (LOD 10 pg/mL). The usefulness of the immunosensor was evaluated by analyzing spiked urine at different pg/mL concentration levels.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信