反振荡流孔板原位标定及改进的振荡水柱模型试验性能预测

Alan Fleming, Gregor Macfarlane
{"title":"反振荡流孔板原位标定及改进的振荡水柱模型试验性能预测","authors":"Alan Fleming,&nbsp;Gregor Macfarlane","doi":"10.1016/j.ijome.2017.01.005","DOIUrl":null,"url":null,"abstract":"<div><p>Performance characterization of oscillating water column (OWC) wave energy converters (WEC) is commonly assessed by conducting physical scale model experiments of OWC models fitted with orifice plates to the air chamber to both; simulate the power take off (PTO), and measure the air flow rate. Generally it is assumed that a single calibration factor can be used for bi-directional air flow measurement, however this paper shows the assumption can be in-accurate and that it is necessary to have separate inflow and outflow calibration factors. This paper presents (i) a novel method for in-situ calibration of an orifice and (ii) a simple algorithm to reduce noise during air flow reversal (low air chamber pressure differential). Application of this technique results in more accurate flow rate prediction and consequently, better prediction of the power absorbed by the power take-off for OWCs.</p></div>","PeriodicalId":100705,"journal":{"name":"International Journal of Marine Energy","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2017-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.ijome.2017.01.005","citationCount":"14","resultStr":"{\"title\":\"In-situ orifice calibration for reversing oscillating flow and improved performance prediction for oscillating water column model test experiments\",\"authors\":\"Alan Fleming,&nbsp;Gregor Macfarlane\",\"doi\":\"10.1016/j.ijome.2017.01.005\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Performance characterization of oscillating water column (OWC) wave energy converters (WEC) is commonly assessed by conducting physical scale model experiments of OWC models fitted with orifice plates to the air chamber to both; simulate the power take off (PTO), and measure the air flow rate. Generally it is assumed that a single calibration factor can be used for bi-directional air flow measurement, however this paper shows the assumption can be in-accurate and that it is necessary to have separate inflow and outflow calibration factors. This paper presents (i) a novel method for in-situ calibration of an orifice and (ii) a simple algorithm to reduce noise during air flow reversal (low air chamber pressure differential). Application of this technique results in more accurate flow rate prediction and consequently, better prediction of the power absorbed by the power take-off for OWCs.</p></div>\",\"PeriodicalId\":100705,\"journal\":{\"name\":\"International Journal of Marine Energy\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/j.ijome.2017.01.005\",\"citationCount\":\"14\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Marine Energy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S221416691730005X\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Marine Energy","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S221416691730005X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 14

摘要

振荡水柱(OWC)波浪能转换器(WEC)的性能特性通常是通过在气室上安装孔板的OWC模型进行物理比例模型实验来评估的;模拟动力起飞(PTO),并测量空气流量。通常假设双向气流测量可以使用单个校准因子,但本文表明该假设可能不准确,需要单独设置流入和流出校准因子。本文提出了(i)一种新的孔板原位校准方法和(ii)一种简单的算法来降低气流反转时的噪声(低气室压差)。应用该技术可以更准确地预测流量,从而更好地预测空压机功率输出所吸收的功率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
In-situ orifice calibration for reversing oscillating flow and improved performance prediction for oscillating water column model test experiments

Performance characterization of oscillating water column (OWC) wave energy converters (WEC) is commonly assessed by conducting physical scale model experiments of OWC models fitted with orifice plates to the air chamber to both; simulate the power take off (PTO), and measure the air flow rate. Generally it is assumed that a single calibration factor can be used for bi-directional air flow measurement, however this paper shows the assumption can be in-accurate and that it is necessary to have separate inflow and outflow calibration factors. This paper presents (i) a novel method for in-situ calibration of an orifice and (ii) a simple algorithm to reduce noise during air flow reversal (low air chamber pressure differential). Application of this technique results in more accurate flow rate prediction and consequently, better prediction of the power absorbed by the power take-off for OWCs.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信