考虑批量充电站和分布式发电的谐波畸变改善

S. S. Nasir, R. Ayop, J. Jamian
{"title":"考虑批量充电站和分布式发电的谐波畸变改善","authors":"S. S. Nasir, R. Ayop, J. Jamian","doi":"10.1109/PECon48942.2020.9314585","DOIUrl":null,"url":null,"abstract":"The extensive usage of the charging station (CS) due to the popularity of electric vehicle (EV) conveys the adverse influences on the existing power system. Higher penetration of CS, especially without proper coordination, may cause multiple issues such as increasing demand and introduce harmonic distortion. The present of harmonic distortion from CS based on the design of power conversion, which requires electronic devices. The harmonic from CS typically based on the state of charge (SOC) of the battery. Other than that, the CS demand pattern ordinarily difficult to control, especially for the load that has a mixed routine. Based on past research, the CS operation can be operated from residence, parking lot and specific station. This research focuses on minimization total harmonic distortion (THD) for voltage and current parameters by seeing CS from residential. The simulation-based on the 48-bus radial distribution system with two residential areas. Then, suitable sizing and placement of multiple passive filters used to minimize harmonic distortion with assistance metaheuristic technique approach. From results, the proposed method able to reduce THD voltage and current concurrently for overall busses and medium voltage lines. The proposed method is useful to assist utility to mitigate high penetration harmonic distortion issues.","PeriodicalId":6768,"journal":{"name":"2020 IEEE International Conference on Power and Energy (PECon)","volume":"3 1","pages":"276-281"},"PeriodicalIF":0.0000,"publicationDate":"2020-12-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Harmonic Distortion Improvement Considering Bulk Charging Station and Distributed Generation\",\"authors\":\"S. S. Nasir, R. Ayop, J. Jamian\",\"doi\":\"10.1109/PECon48942.2020.9314585\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The extensive usage of the charging station (CS) due to the popularity of electric vehicle (EV) conveys the adverse influences on the existing power system. Higher penetration of CS, especially without proper coordination, may cause multiple issues such as increasing demand and introduce harmonic distortion. The present of harmonic distortion from CS based on the design of power conversion, which requires electronic devices. The harmonic from CS typically based on the state of charge (SOC) of the battery. Other than that, the CS demand pattern ordinarily difficult to control, especially for the load that has a mixed routine. Based on past research, the CS operation can be operated from residence, parking lot and specific station. This research focuses on minimization total harmonic distortion (THD) for voltage and current parameters by seeing CS from residential. The simulation-based on the 48-bus radial distribution system with two residential areas. Then, suitable sizing and placement of multiple passive filters used to minimize harmonic distortion with assistance metaheuristic technique approach. From results, the proposed method able to reduce THD voltage and current concurrently for overall busses and medium voltage lines. The proposed method is useful to assist utility to mitigate high penetration harmonic distortion issues.\",\"PeriodicalId\":6768,\"journal\":{\"name\":\"2020 IEEE International Conference on Power and Energy (PECon)\",\"volume\":\"3 1\",\"pages\":\"276-281\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-12-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE International Conference on Power and Energy (PECon)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PECon48942.2020.9314585\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE International Conference on Power and Energy (PECon)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PECon48942.2020.9314585","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

随着电动汽车的普及,充电站的广泛使用对现有的电力系统产生了不利的影响。CS的高渗透,特别是没有适当的协调,可能会导致需求增加和谐波失真等多重问题。基于功率转换设计的CS谐波失真问题,需要电子器件来解决。来自CS的谐波通常基于电池的充电状态(SOC)。除此之外,CS需求模式通常难以控制,特别是对于具有混合例程的负载。根据以往的研究,CS操作可以从住宅、停车场和特定车站进行操作。本研究的重点是通过观察住宅的CS来最小化电压和电流参数的总谐波失真(THD)。基于48总线径向配电系统的两个居民区的仿真。然后,采用辅助元启发式方法,采用合适的尺寸和位置的多个无源滤波器来最小化谐波失真。结果表明,该方法能够同时降低总母线和中压线路的THD电压和电流。该方法有助于缓解高穿通谐波失真问题。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Harmonic Distortion Improvement Considering Bulk Charging Station and Distributed Generation
The extensive usage of the charging station (CS) due to the popularity of electric vehicle (EV) conveys the adverse influences on the existing power system. Higher penetration of CS, especially without proper coordination, may cause multiple issues such as increasing demand and introduce harmonic distortion. The present of harmonic distortion from CS based on the design of power conversion, which requires electronic devices. The harmonic from CS typically based on the state of charge (SOC) of the battery. Other than that, the CS demand pattern ordinarily difficult to control, especially for the load that has a mixed routine. Based on past research, the CS operation can be operated from residence, parking lot and specific station. This research focuses on minimization total harmonic distortion (THD) for voltage and current parameters by seeing CS from residential. The simulation-based on the 48-bus radial distribution system with two residential areas. Then, suitable sizing and placement of multiple passive filters used to minimize harmonic distortion with assistance metaheuristic technique approach. From results, the proposed method able to reduce THD voltage and current concurrently for overall busses and medium voltage lines. The proposed method is useful to assist utility to mitigate high penetration harmonic distortion issues.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信