{"title":"流动注射分光光度法测定Perazine","authors":"W. Misiuk, P. Hałaburda","doi":"10.1081/TMA-120017896","DOIUrl":null,"url":null,"abstract":"Abstract The flow injection method, involving spectrophotometric detection, is proposed for the determination of perazine. The procedure is based on the oxidation of perazine by cerium(IV) sulphate(VI). Concentrations with perazine in the range 120–300 ppm have been determined with the relative standard deviation of 1.0%. The presented method was applied to the determination of perazine in pharmaceutical formulations.","PeriodicalId":17525,"journal":{"name":"Journal of Trace and Microprobe Techniques","volume":"95 1","pages":"102 - 95"},"PeriodicalIF":0.0000,"publicationDate":"2003-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Flow Injection Spectrophotometric Determination of Perazine\",\"authors\":\"W. Misiuk, P. Hałaburda\",\"doi\":\"10.1081/TMA-120017896\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract The flow injection method, involving spectrophotometric detection, is proposed for the determination of perazine. The procedure is based on the oxidation of perazine by cerium(IV) sulphate(VI). Concentrations with perazine in the range 120–300 ppm have been determined with the relative standard deviation of 1.0%. The presented method was applied to the determination of perazine in pharmaceutical formulations.\",\"PeriodicalId\":17525,\"journal\":{\"name\":\"Journal of Trace and Microprobe Techniques\",\"volume\":\"95 1\",\"pages\":\"102 - 95\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-01-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Trace and Microprobe Techniques\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1081/TMA-120017896\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Trace and Microprobe Techniques","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1081/TMA-120017896","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Flow Injection Spectrophotometric Determination of Perazine
Abstract The flow injection method, involving spectrophotometric detection, is proposed for the determination of perazine. The procedure is based on the oxidation of perazine by cerium(IV) sulphate(VI). Concentrations with perazine in the range 120–300 ppm have been determined with the relative standard deviation of 1.0%. The presented method was applied to the determination of perazine in pharmaceutical formulations.