Duygu YALINBAŞ YETER, Erman Bozali̇, Caner. Kara, S. Sarı, Demet Dursun
{"title":"Yeni tanı konmuş dikkat eksikliği hiperaktivite bozukluğu olan çocuklarda fotoscreener ve el tipi otorefraktometrenin sikloplejik otorefraktometri ile karşılaştırılması","authors":"Duygu YALINBAŞ YETER, Erman Bozali̇, Caner. Kara, S. Sarı, Demet Dursun","doi":"10.31362/patd.1140073","DOIUrl":null,"url":null,"abstract":"Purpose: To compare non-cycloplegic refraction measurements of two photoscreeners and the hand-held autorefractometer with cycloplegic measurements of the autorefractometer in patients with attention deficit hyperactivity disorder (ADHD). \nMeterials and methods: This cross-sectional, comparative study consisted of 53 children who were newly diagnosed with ADHD. We compared spherical, cylindrical, cylindrical axis and spherical equivalent (SE) measurements in Plusoptix A12, Spot Vision Screener, and Retinomax K-plus Screen with Tonoref II. Reliability was analyzed by using the interclass correlation coefficient (ICC) and Bland-Altman plot was used to evaluate the agreement between devices. \nResults: The mean age of children was 9.45 ± 1.68. All of the devices measured spherical power and SE significantly more myopic than the Tonoref II. While The Spot Vision Screener, PlusoptiX A12, and Tonoref II provided similar cylindrical power, Retinomax K-plus Screen measured significantly lower than the Tonoref II. The excellent reliability was detected in spherical power, cylindrical power, SE and J0 between Tonoref II and PlusoptiX A12 (ICC:0.930, 0.921, 0.927 and 0.920, respectively. All of the hand-held devices showed excellent reliability in terms of cylindrical power and J0 (ICC>0.90, for all) and good reliability for J45 (ICC:0.75-0.90 for all). \nConclusion: Despite all devices having advantages or disadvantages, Plusoptix A12 showed excellent reliability for detecting refractive errors in children with ADHD.","PeriodicalId":19789,"journal":{"name":"Pamukkale Medical Journal","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pamukkale Medical Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31362/patd.1140073","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:比较两种光筛和手持式自折射仪在注意缺陷多动障碍(ADHD)患者中的非独眼性屈光测量结果与独眼性自折射仪的测量结果。材料和方法:这项横断面比较研究包括53名新诊断为ADHD的儿童。我们比较了Plusoptix A12、Spot Vision Screener和Retinomax K-plus Screen与Tonoref II的球面、圆柱、圆柱轴和球面等效(SE)测量结果。采用类间相关系数(ICC)分析信度,采用Bland-Altman图评价设备间的一致性。结果:患儿平均年龄为9.45±1.68岁。所有设备测量的球面功率和SE明显比Tonoref II近视。虽然Spot Vision Screener, PlusoptiX A12和Tonoref II提供类似的圆柱形功率,但Retinomax K-plus Screen的测量值明显低于Tonoref II。Tonoref II与PlusoptiX A12的球形功率、圆柱形功率、SE和J0均具有良好的信度(ICC分别为0.930、0.921、0.927和0.920)。所有的手持设备在圆柱功率和J0 (ICC>0.90,所有)和J45 (ICC:0.75-0.90,所有)方面都表现出良好的可靠性。结论:尽管所有设备都有优缺点,但Plusoptix A12在检测ADHD儿童屈光不正方面表现出出色的可靠性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Yeni tanı konmuş dikkat eksikliği hiperaktivite bozukluğu olan çocuklarda fotoscreener ve el tipi otorefraktometrenin sikloplejik otorefraktometri ile karşılaştırılması
Purpose: To compare non-cycloplegic refraction measurements of two photoscreeners and the hand-held autorefractometer with cycloplegic measurements of the autorefractometer in patients with attention deficit hyperactivity disorder (ADHD). Meterials and methods: This cross-sectional, comparative study consisted of 53 children who were newly diagnosed with ADHD. We compared spherical, cylindrical, cylindrical axis and spherical equivalent (SE) measurements in Plusoptix A12, Spot Vision Screener, and Retinomax K-plus Screen with Tonoref II. Reliability was analyzed by using the interclass correlation coefficient (ICC) and Bland-Altman plot was used to evaluate the agreement between devices. Results: The mean age of children was 9.45 ± 1.68. All of the devices measured spherical power and SE significantly more myopic than the Tonoref II. While The Spot Vision Screener, PlusoptiX A12, and Tonoref II provided similar cylindrical power, Retinomax K-plus Screen measured significantly lower than the Tonoref II. The excellent reliability was detected in spherical power, cylindrical power, SE and J0 between Tonoref II and PlusoptiX A12 (ICC:0.930, 0.921, 0.927 and 0.920, respectively. All of the hand-held devices showed excellent reliability in terms of cylindrical power and J0 (ICC>0.90, for all) and good reliability for J45 (ICC:0.75-0.90 for all). Conclusion: Despite all devices having advantages or disadvantages, Plusoptix A12 showed excellent reliability for detecting refractive errors in children with ADHD.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.20
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信