蒸发冷却器简化热技术计算的实验研究

Zhang Dan, Zhaohui Wei
{"title":"蒸发冷却器简化热技术计算的实验研究","authors":"Zhang Dan, Zhaohui Wei","doi":"10.1109/CCIENG.2011.6008030","DOIUrl":null,"url":null,"abstract":"Evaporative cooling is energy efficient and environment protective. However, little research has been done on the simplified and applied thermo-technical calculation method. In order to improve the practicability and advantage of evaporative cooling unit, and make the unit manufacture standard, a thermo-technical calculation for a plate indirect evaporative cooling unit and a packing direct evaporative cooling unit are simplified by experiments base on engineering optimization theory. In the experiments, an optimal water-spraying density was gained for the packing direct evaporative cooling unit, with the aluminum foil packing specific surface area of 500m2/m3; as well as an optimal water-spraying density for plate indirect evaporative cooling unit, with primary air channel length of 4mm, and secondary air channel length of 6mm.","PeriodicalId":6316,"journal":{"name":"2011 IEEE 2nd International Conference on Computing, Control and Industrial Engineering","volume":"14 1","pages":"348-351"},"PeriodicalIF":0.0000,"publicationDate":"2011-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Experimental study on simplified thermo-technical calculation for evaporative coolers\",\"authors\":\"Zhang Dan, Zhaohui Wei\",\"doi\":\"10.1109/CCIENG.2011.6008030\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Evaporative cooling is energy efficient and environment protective. However, little research has been done on the simplified and applied thermo-technical calculation method. In order to improve the practicability and advantage of evaporative cooling unit, and make the unit manufacture standard, a thermo-technical calculation for a plate indirect evaporative cooling unit and a packing direct evaporative cooling unit are simplified by experiments base on engineering optimization theory. In the experiments, an optimal water-spraying density was gained for the packing direct evaporative cooling unit, with the aluminum foil packing specific surface area of 500m2/m3; as well as an optimal water-spraying density for plate indirect evaporative cooling unit, with primary air channel length of 4mm, and secondary air channel length of 6mm.\",\"PeriodicalId\":6316,\"journal\":{\"name\":\"2011 IEEE 2nd International Conference on Computing, Control and Industrial Engineering\",\"volume\":\"14 1\",\"pages\":\"348-351\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 IEEE 2nd International Conference on Computing, Control and Industrial Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CCIENG.2011.6008030\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 IEEE 2nd International Conference on Computing, Control and Industrial Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CCIENG.2011.6008030","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

蒸发冷却既节能又环保。然而,关于简化和应用的热技术计算方法的研究很少。为了提高蒸发冷却装置的实用性和优越性,制定蒸发冷却装置的制造标准,基于工程优化理论,通过实验简化了板式间接蒸发冷却装置和填料直接蒸发冷却装置的热技术计算。实验结果表明,填料直接蒸发冷却机组的最佳喷水密度为铝箔填料比表面积为500m2/m3;以及板式间接蒸发冷却机组的最佳喷水密度,一次风道长度为4mm,二次风道长度为6mm。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Experimental study on simplified thermo-technical calculation for evaporative coolers
Evaporative cooling is energy efficient and environment protective. However, little research has been done on the simplified and applied thermo-technical calculation method. In order to improve the practicability and advantage of evaporative cooling unit, and make the unit manufacture standard, a thermo-technical calculation for a plate indirect evaporative cooling unit and a packing direct evaporative cooling unit are simplified by experiments base on engineering optimization theory. In the experiments, an optimal water-spraying density was gained for the packing direct evaporative cooling unit, with the aluminum foil packing specific surface area of 500m2/m3; as well as an optimal water-spraying density for plate indirect evaporative cooling unit, with primary air channel length of 4mm, and secondary air channel length of 6mm.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信