A. Brilinskiy, G. Evdokunin, V. S. Chudny, R. I. Mingazov, T. A. Ponomarev
{"title":"干式变压器有载分接开关绝缘原因分析","authors":"A. Brilinskiy, G. Evdokunin, V. S. Chudny, R. I. Mingazov, T. A. Ponomarev","doi":"10.1109/EICONRUS.2018.8317168","DOIUrl":null,"url":null,"abstract":"The article represents the analysis of the causes of damage on the on-load tap-changer of a dry-type transformer installed at a 35 kV substation under ground fault in a network with isolated neutral. In order to analyze these processes, the well-known technique of modeling transients in a transformer [1, 2] is supplemented with account of the interturn and interwinding capacitances of the transformer determined from the picture of the electrostatic field.","PeriodicalId":6562,"journal":{"name":"2018 IEEE Conference of Russian Young Researchers in Electrical and Electronic Engineering (EIConRus)","volume":"1 1","pages":"591-597"},"PeriodicalIF":0.0000,"publicationDate":"2018-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Investigation of causes of dry-type transformer on-load tap-changer insulation\",\"authors\":\"A. Brilinskiy, G. Evdokunin, V. S. Chudny, R. I. Mingazov, T. A. Ponomarev\",\"doi\":\"10.1109/EICONRUS.2018.8317168\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The article represents the analysis of the causes of damage on the on-load tap-changer of a dry-type transformer installed at a 35 kV substation under ground fault in a network with isolated neutral. In order to analyze these processes, the well-known technique of modeling transients in a transformer [1, 2] is supplemented with account of the interturn and interwinding capacitances of the transformer determined from the picture of the electrostatic field.\",\"PeriodicalId\":6562,\"journal\":{\"name\":\"2018 IEEE Conference of Russian Young Researchers in Electrical and Electronic Engineering (EIConRus)\",\"volume\":\"1 1\",\"pages\":\"591-597\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 IEEE Conference of Russian Young Researchers in Electrical and Electronic Engineering (EIConRus)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EICONRUS.2018.8317168\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE Conference of Russian Young Researchers in Electrical and Electronic Engineering (EIConRus)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EICONRUS.2018.8317168","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Investigation of causes of dry-type transformer on-load tap-changer insulation
The article represents the analysis of the causes of damage on the on-load tap-changer of a dry-type transformer installed at a 35 kV substation under ground fault in a network with isolated neutral. In order to analyze these processes, the well-known technique of modeling transients in a transformer [1, 2] is supplemented with account of the interturn and interwinding capacitances of the transformer determined from the picture of the electrostatic field.