T. Nakamori, Yuga Ouchi, Risa Ogihara, T. Terasawa, Yuhei Kato, S. Shibata
{"title":"单片盖革雪崩光电二极管阵列光学光子计数成像仪的研制","authors":"T. Nakamori, Yuga Ouchi, Risa Ogihara, T. Terasawa, Yuhei Kato, S. Shibata","doi":"10.1093/pasj/psaa106","DOIUrl":null,"url":null,"abstract":"We have developed a sensor system based on an optical photon-counting imager with high timing resolution, aiming for highly time-variable astronomical phenomena. The detector is a monolithic Geiger-mode avalanche photodiode array customized in a Multi-Pixel Photon Counter with a response time on the order of nanoseconds. This paper evaluates the basic performance of the sensor and confirms the gain linearity, uniformity, and low dark count. We demonstrate the system's ability to detect the period of a flashing LED, using a data acquisition system developed to obtain the light curve with a time bin of 100 microseconds. The Crab pulsar was observed using a 35-cm telescope without cooling, and the equipment detected optical pulses with a period consistent with the data from the radio ephemeris. Although improvements to the system will be necessary for more reliability, the system has been proven to be a promising device for exploring the time-domain optical astronomy.","PeriodicalId":8459,"journal":{"name":"arXiv: Instrumentation and Methods for Astrophysics","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-10-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development of an optical photon-counting imager with a monolithic Geiger Avalanche Photodiode array\",\"authors\":\"T. Nakamori, Yuga Ouchi, Risa Ogihara, T. Terasawa, Yuhei Kato, S. Shibata\",\"doi\":\"10.1093/pasj/psaa106\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We have developed a sensor system based on an optical photon-counting imager with high timing resolution, aiming for highly time-variable astronomical phenomena. The detector is a monolithic Geiger-mode avalanche photodiode array customized in a Multi-Pixel Photon Counter with a response time on the order of nanoseconds. This paper evaluates the basic performance of the sensor and confirms the gain linearity, uniformity, and low dark count. We demonstrate the system's ability to detect the period of a flashing LED, using a data acquisition system developed to obtain the light curve with a time bin of 100 microseconds. The Crab pulsar was observed using a 35-cm telescope without cooling, and the equipment detected optical pulses with a period consistent with the data from the radio ephemeris. Although improvements to the system will be necessary for more reliability, the system has been proven to be a promising device for exploring the time-domain optical astronomy.\",\"PeriodicalId\":8459,\"journal\":{\"name\":\"arXiv: Instrumentation and Methods for Astrophysics\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-10-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"arXiv: Instrumentation and Methods for Astrophysics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1093/pasj/psaa106\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"arXiv: Instrumentation and Methods for Astrophysics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/pasj/psaa106","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Development of an optical photon-counting imager with a monolithic Geiger Avalanche Photodiode array
We have developed a sensor system based on an optical photon-counting imager with high timing resolution, aiming for highly time-variable astronomical phenomena. The detector is a monolithic Geiger-mode avalanche photodiode array customized in a Multi-Pixel Photon Counter with a response time on the order of nanoseconds. This paper evaluates the basic performance of the sensor and confirms the gain linearity, uniformity, and low dark count. We demonstrate the system's ability to detect the period of a flashing LED, using a data acquisition system developed to obtain the light curve with a time bin of 100 microseconds. The Crab pulsar was observed using a 35-cm telescope without cooling, and the equipment detected optical pulses with a period consistent with the data from the radio ephemeris. Although improvements to the system will be necessary for more reliability, the system has been proven to be a promising device for exploring the time-domain optical astronomy.