原位电化学监测:从远程传感器到潜水微实验室

Joseph Wang
{"title":"原位电化学监测:从远程传感器到潜水微实验室","authors":"Joseph Wang","doi":"10.1002/1098-2728(2000)12:4<178::AID-LRA2>3.0.CO;2-K","DOIUrl":null,"url":null,"abstract":"<p>This article reviews new concepts for in situ environmental analysis based on novel electrochemical sensing strategies. Several new strategies are covered, including the use of remotely deployed sensors and submersible (“lab-on-cable”) analyzers. These devices offer a fast return of the chemical information in a safe and timely manner. The new concepts are discussed in connection to the in situ monitoring of priority organic and inorganic contaminants. Such devices should have an enormous impact upon pollution control and prevention, because they should lead to a substantially more effective and economic monitoring of priority pollutants. © 2000 John Wiley &amp; Sons, Inc. Lab Robotics and Automation 12:178–182, 2000</p>","PeriodicalId":100863,"journal":{"name":"Laboratory Robotics and Automation","volume":"12 4","pages":"178-182"},"PeriodicalIF":0.0000,"publicationDate":"2000-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/1098-2728(2000)12:4<178::AID-LRA2>3.0.CO;2-K","citationCount":"11","resultStr":"{\"title\":\"In situ electrochemical monitoring: from remote sensors to submersible microlaboratories\",\"authors\":\"Joseph Wang\",\"doi\":\"10.1002/1098-2728(2000)12:4<178::AID-LRA2>3.0.CO;2-K\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>This article reviews new concepts for in situ environmental analysis based on novel electrochemical sensing strategies. Several new strategies are covered, including the use of remotely deployed sensors and submersible (“lab-on-cable”) analyzers. These devices offer a fast return of the chemical information in a safe and timely manner. The new concepts are discussed in connection to the in situ monitoring of priority organic and inorganic contaminants. Such devices should have an enormous impact upon pollution control and prevention, because they should lead to a substantially more effective and economic monitoring of priority pollutants. © 2000 John Wiley &amp; Sons, Inc. Lab Robotics and Automation 12:178–182, 2000</p>\",\"PeriodicalId\":100863,\"journal\":{\"name\":\"Laboratory Robotics and Automation\",\"volume\":\"12 4\",\"pages\":\"178-182\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-08-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1002/1098-2728(2000)12:4<178::AID-LRA2>3.0.CO;2-K\",\"citationCount\":\"11\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Laboratory Robotics and Automation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/1098-2728%282000%2912%3A4%3C178%3A%3AAID-LRA2%3E3.0.CO%3B2-K\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Laboratory Robotics and Automation","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/1098-2728%282000%2912%3A4%3C178%3A%3AAID-LRA2%3E3.0.CO%3B2-K","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

摘要

本文综述了基于新型电化学传感策略的原位环境分析新概念。介绍了几种新策略,包括使用远程部署的传感器和潜水式(“实验室-电缆”)分析仪。这些设备可以安全、及时地快速返回化学信息。讨论了重点有机和无机污染物现场监测的新概念。这种装置应对污染控制和预防产生巨大影响,因为它们应导致对优先污染物进行更有效和更经济的监测。©2000 John Wiley &儿子,Inc。实验室机器人与自动化,2000
本文章由计算机程序翻译,如有差异,请以英文原文为准。
In situ electrochemical monitoring: from remote sensors to submersible microlaboratories

This article reviews new concepts for in situ environmental analysis based on novel electrochemical sensing strategies. Several new strategies are covered, including the use of remotely deployed sensors and submersible (“lab-on-cable”) analyzers. These devices offer a fast return of the chemical information in a safe and timely manner. The new concepts are discussed in connection to the in situ monitoring of priority organic and inorganic contaminants. Such devices should have an enormous impact upon pollution control and prevention, because they should lead to a substantially more effective and economic monitoring of priority pollutants. © 2000 John Wiley & Sons, Inc. Lab Robotics and Automation 12:178–182, 2000

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信