Dong Yong Park, JiYoon Ahn, Hyeon Jeong Park, Doo Suk Lee, Dae-Hyun Jo, Jonghoon Kim, Choulmin Kim, Heebum Chung, Ji Hye Hwang
{"title":"韩国使用的各种一次性针灸针的形态和化学分析。","authors":"Dong Yong Park, JiYoon Ahn, Hyeon Jeong Park, Doo Suk Lee, Dae-Hyun Jo, Jonghoon Kim, Choulmin Kim, Heebum Chung, Ji Hye Hwang","doi":"10.3831/KPI.2022.25.4.382","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The Korean Industrial Standard (KS) for sterile acupuncture needles was established in 2009 based on research on the quality control of acupuncture needles. We aimed to determine the quality of acupuncture needles available in South Korea in 2021 by examining their surface condition and chemical composition using field-emission scanning electron microscopy (FE-SEM) and energy-dispersive X-ray spectroscopy (EDS).</p><p><strong>Methods: </strong>In South Korea, there are 23 brands of acupuncture needles, and we examined 10-15 needles from each brand, resulting in a total of 285 needles. The microstructures of the needles were assessed by SEM. Using SEM images, we evaluated the acupuncture needle tips for the following defects/aspects scratches, lumps, detached coating, bent tip, and tip sharpness. EDS was used to determine the chemical composition of the selected acupuncture needles.</p><p><strong>Results: </strong>Overall, 88.4% of 285 needles were found to have at least one type of abnormality. The most frequently observed abnormalities were scratches and dents on the surface (68.1%), followed by detached coating (63.2%), and lumps (61.8%); blunt tips were observed in about 24% of them. Of 252 needles with at least one defect, 86.9% had two or more types of defects. The ratio of the number of needles with any defect to that of needles without any defect varied among brands, ranging from 50% to 100%. Regarding foreign materials, higher proportions of Si and O were observed on the needles, indicating incomplete or detached silicone coating.</p><p><strong>Conclusion: </strong>The quality of acupuncture needles varied among brands, suggesting that further improvements can be made through various inspection methods.</p>","PeriodicalId":16769,"journal":{"name":"Journal of Pharmacopuncture","volume":"25 4","pages":"382-389"},"PeriodicalIF":1.2000,"publicationDate":"2022-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/88/ec/jop-25-4-382.PMC9806154.pdf","citationCount":"0","resultStr":"{\"title\":\"Morphological and Chemical Analysis of Various Disposable Acupuncture Needles Used in South Korea.\",\"authors\":\"Dong Yong Park, JiYoon Ahn, Hyeon Jeong Park, Doo Suk Lee, Dae-Hyun Jo, Jonghoon Kim, Choulmin Kim, Heebum Chung, Ji Hye Hwang\",\"doi\":\"10.3831/KPI.2022.25.4.382\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>The Korean Industrial Standard (KS) for sterile acupuncture needles was established in 2009 based on research on the quality control of acupuncture needles. We aimed to determine the quality of acupuncture needles available in South Korea in 2021 by examining their surface condition and chemical composition using field-emission scanning electron microscopy (FE-SEM) and energy-dispersive X-ray spectroscopy (EDS).</p><p><strong>Methods: </strong>In South Korea, there are 23 brands of acupuncture needles, and we examined 10-15 needles from each brand, resulting in a total of 285 needles. The microstructures of the needles were assessed by SEM. Using SEM images, we evaluated the acupuncture needle tips for the following defects/aspects scratches, lumps, detached coating, bent tip, and tip sharpness. EDS was used to determine the chemical composition of the selected acupuncture needles.</p><p><strong>Results: </strong>Overall, 88.4% of 285 needles were found to have at least one type of abnormality. The most frequently observed abnormalities were scratches and dents on the surface (68.1%), followed by detached coating (63.2%), and lumps (61.8%); blunt tips were observed in about 24% of them. Of 252 needles with at least one defect, 86.9% had two or more types of defects. The ratio of the number of needles with any defect to that of needles without any defect varied among brands, ranging from 50% to 100%. Regarding foreign materials, higher proportions of Si and O were observed on the needles, indicating incomplete or detached silicone coating.</p><p><strong>Conclusion: </strong>The quality of acupuncture needles varied among brands, suggesting that further improvements can be made through various inspection methods.</p>\",\"PeriodicalId\":16769,\"journal\":{\"name\":\"Journal of Pharmacopuncture\",\"volume\":\"25 4\",\"pages\":\"382-389\"},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2022-12-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/88/ec/jop-25-4-382.PMC9806154.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Pharmacopuncture\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3831/KPI.2022.25.4.382\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"INTEGRATIVE & COMPLEMENTARY MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Pharmacopuncture","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3831/KPI.2022.25.4.382","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INTEGRATIVE & COMPLEMENTARY MEDICINE","Score":null,"Total":0}
Morphological and Chemical Analysis of Various Disposable Acupuncture Needles Used in South Korea.
Objectives: The Korean Industrial Standard (KS) for sterile acupuncture needles was established in 2009 based on research on the quality control of acupuncture needles. We aimed to determine the quality of acupuncture needles available in South Korea in 2021 by examining their surface condition and chemical composition using field-emission scanning electron microscopy (FE-SEM) and energy-dispersive X-ray spectroscopy (EDS).
Methods: In South Korea, there are 23 brands of acupuncture needles, and we examined 10-15 needles from each brand, resulting in a total of 285 needles. The microstructures of the needles were assessed by SEM. Using SEM images, we evaluated the acupuncture needle tips for the following defects/aspects scratches, lumps, detached coating, bent tip, and tip sharpness. EDS was used to determine the chemical composition of the selected acupuncture needles.
Results: Overall, 88.4% of 285 needles were found to have at least one type of abnormality. The most frequently observed abnormalities were scratches and dents on the surface (68.1%), followed by detached coating (63.2%), and lumps (61.8%); blunt tips were observed in about 24% of them. Of 252 needles with at least one defect, 86.9% had two or more types of defects. The ratio of the number of needles with any defect to that of needles without any defect varied among brands, ranging from 50% to 100%. Regarding foreign materials, higher proportions of Si and O were observed on the needles, indicating incomplete or detached silicone coating.
Conclusion: The quality of acupuncture needles varied among brands, suggesting that further improvements can be made through various inspection methods.
期刊介绍:
The Journal of Pharmacopuncture covers a wide range of basic and clinical science research relevant to all aspects of the biotechnology of integrated approaches using both pharmacology and acupuncture therapeutics, including research involving pharmacology, acupuncture studies and pharmacopuncture studies. The subjects are mainly divided into three categories: pharmacology (applied phytomedicine, plant sciences, pharmacology, toxicology, medicinal plants, traditional medicines, herbal medicine, Sasang constitutional medicine, herbal formulae, foods, agricultural technologies, naturopathy, etc.), acupuncture (acupressure, electroacupuncture, laser acupuncture, moxibustion, cupping, etc.), and pharmacopuncture (aqua-acupuncture, meridian pharmacopuncture, eight-principles pharmacopuncture, animal-based pharmacopuncture, mountain ginseng pharmacopuncture, bee venom therapy, needle embedding therapy, implant therapy, etc.). Other categories include chuna treatment, veterinary acupuncture and related animal studies, alternative medicines for treating cancer and cancer-related symptoms, etc. Broader topical coverage on the effects of acupuncture, the medical plants used in traditional and alternative medicine, pharmacological action and other related modalities, such as anthroposophy, homeopathy, ayurveda, bioelectromagnetic therapy, chiropractic, neural therapy and meditation, can be considered to be within the journal’s scope if based on acupoints and meridians. Submissions of original articles, review articles, systematic reviews, case reports, brief reports, opinions, commentaries, medical lectures, letters to the editor, photo-essays, technical notes, and book reviews are encouraged. Providing free access to the full text of all current and archived articles on its website (www.journal.ac), also searchable through a Google Scholar search.