超声引导下预防性腹主动脉球囊闭塞治疗胎盘增生谱系障碍:一个病例系列。

IF 1.1 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Mandeep Grewal, Michael Magro, Krishna Prasad Bellam Premnath, Sorina Bologa, Chineze Otigbah
{"title":"超声引导下预防性腹主动脉球囊闭塞治疗胎盘增生谱系障碍:一个病例系列。","authors":"Mandeep Grewal,&nbsp;Michael Magro,&nbsp;Krishna Prasad Bellam Premnath,&nbsp;Sorina Bologa,&nbsp;Chineze Otigbah","doi":"10.25259/JCIS_141_2022","DOIUrl":null,"url":null,"abstract":"<p><p>Placenta accreta spectrum (PAS) disorder is one of the most dangerous conditions that can affect pregnancy and its incidence is increasing secondary to rising cesarean section rates worldwide. The standard treatment is frequently elective hysterectomy at the time of cesarean delivery; however, uterine and fertility preserving surgery is becoming more common. In the pursuit of a reduction in blood loss and associated maternal morbidity, occlusive vascular balloons are increasingly used at the time of surgery, usually placed with fluoroscopic guidance. Occlusive balloons placed in the infrarenal aorta have been shown in the literature to be superior in terms of blood loss and hysterectomy rates than those placed more distally, such as within iliac or uterine arteries. We present the first five cases performed in Europe of ultrasound-guided infrarenal aortic balloon placement before cesarean for PAS disorder, and describe the technique we used, which provided reduced blood loss, a clearer operating field and avoided fetal and maternal exposure to radiation and intravenous contrast.</p>","PeriodicalId":15512,"journal":{"name":"Journal of Clinical Imaging Science","volume":"13 ","pages":"9"},"PeriodicalIF":1.1000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/5c/25/JCIS-13-9.PMC9990842.pdf","citationCount":"0","resultStr":"{\"title\":\"Ultrasound-guided prophylactic abdominal aortic balloon occlusion for placenta accreta spectrum disorder: A case series.\",\"authors\":\"Mandeep Grewal,&nbsp;Michael Magro,&nbsp;Krishna Prasad Bellam Premnath,&nbsp;Sorina Bologa,&nbsp;Chineze Otigbah\",\"doi\":\"10.25259/JCIS_141_2022\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Placenta accreta spectrum (PAS) disorder is one of the most dangerous conditions that can affect pregnancy and its incidence is increasing secondary to rising cesarean section rates worldwide. The standard treatment is frequently elective hysterectomy at the time of cesarean delivery; however, uterine and fertility preserving surgery is becoming more common. In the pursuit of a reduction in blood loss and associated maternal morbidity, occlusive vascular balloons are increasingly used at the time of surgery, usually placed with fluoroscopic guidance. Occlusive balloons placed in the infrarenal aorta have been shown in the literature to be superior in terms of blood loss and hysterectomy rates than those placed more distally, such as within iliac or uterine arteries. We present the first five cases performed in Europe of ultrasound-guided infrarenal aortic balloon placement before cesarean for PAS disorder, and describe the technique we used, which provided reduced blood loss, a clearer operating field and avoided fetal and maternal exposure to radiation and intravenous contrast.</p>\",\"PeriodicalId\":15512,\"journal\":{\"name\":\"Journal of Clinical Imaging Science\",\"volume\":\"13 \",\"pages\":\"9\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/5c/25/JCIS-13-9.PMC9990842.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Clinical Imaging Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.25259/JCIS_141_2022\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Imaging Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25259/JCIS_141_2022","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

胎盘增生谱(PAS)障碍是影响妊娠的最危险的疾病之一,其发病率随着全世界剖宫产率的上升而增加。标准的治疗通常是在剖宫产时选择子宫切除术;然而,保留子宫和生育能力的手术正变得越来越普遍。为了减少失血和相关的产妇发病率,手术时越来越多地使用闭塞性血管球囊,通常在透视指导下放置。文献显示,在肾下主动脉放置闭塞性球囊,在失血量和子宫切除术率方面优于放置更远端的球囊,如髂动脉或子宫动脉。我们介绍了在欧洲进行的前5例超声引导下肾下主动脉球囊放置在剖宫产前治疗PAS疾病的病例,并描述了我们使用的技术,该技术提供了减少失血,更清晰的手术区域,避免了胎儿和母亲暴露于辐射和静脉造影剂。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Ultrasound-guided prophylactic abdominal aortic balloon occlusion for placenta accreta spectrum disorder: A case series.

Ultrasound-guided prophylactic abdominal aortic balloon occlusion for placenta accreta spectrum disorder: A case series.

Ultrasound-guided prophylactic abdominal aortic balloon occlusion for placenta accreta spectrum disorder: A case series.

Placenta accreta spectrum (PAS) disorder is one of the most dangerous conditions that can affect pregnancy and its incidence is increasing secondary to rising cesarean section rates worldwide. The standard treatment is frequently elective hysterectomy at the time of cesarean delivery; however, uterine and fertility preserving surgery is becoming more common. In the pursuit of a reduction in blood loss and associated maternal morbidity, occlusive vascular balloons are increasingly used at the time of surgery, usually placed with fluoroscopic guidance. Occlusive balloons placed in the infrarenal aorta have been shown in the literature to be superior in terms of blood loss and hysterectomy rates than those placed more distally, such as within iliac or uterine arteries. We present the first five cases performed in Europe of ultrasound-guided infrarenal aortic balloon placement before cesarean for PAS disorder, and describe the technique we used, which provided reduced blood loss, a clearer operating field and avoided fetal and maternal exposure to radiation and intravenous contrast.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Clinical Imaging Science
Journal of Clinical Imaging Science RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
2.00
自引率
0.00%
发文量
65
期刊介绍: The Journal of Clinical Imaging Science (JCIS) is an open access peer-reviewed journal committed to publishing high-quality articles in the field of Imaging Science. The journal aims to present Imaging Science and relevant clinical information in an understandable and useful format. The journal is owned and published by the Scientific Scholar. Audience Our audience includes Radiologists, Researchers, Clinicians, medical professionals and students. Review process JCIS has a highly rigorous peer-review process that makes sure that manuscripts are scientifically accurate, relevant, novel and important. Authors disclose all conflicts, affiliations and financial associations such that the published content is not biased.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信