谐波叠加直流电压下氟化油纸绝缘热老化相关表面电荷特性

Wenbo Zhu, M. Fu, S. Hou, B. Hui, Yifan Zhang, B. Feng, Jun Chen, Le Gu, Huihong Huang
{"title":"谐波叠加直流电压下氟化油纸绝缘热老化相关表面电荷特性","authors":"Wenbo Zhu, M. Fu, S. Hou, B. Hui, Yifan Zhang, B. Feng, Jun Chen, Le Gu, Huihong Huang","doi":"10.1109/ICEMPE51623.2021.9509134","DOIUrl":null,"url":null,"abstract":"The oil-impregnated paper in the converter transformer, especially in the valve side bushing, is suffered by the complicated electric field. By reason of the power electronics and non-linear equipment, the oil-impregnated paper is subject to the harmonic voltages. The insulating aging is more prominent in contrast with the power transformer. Under this condition, the charges are capable to accumulate on the surface of oil-impregnated paper, which will lead to the distorting the electric field and accelerating the insulating degradation. Consequently, the performance deterioration of oil-paper insulation is inevitable. Surface fluorination is an effective approach of modifying the chemical components of polymer matrix. Hence, this paper is dedicated to research effects of thermal aging on the surface charge dynamic characteristics of fluorinated oil-paper insulation under the harmonic superimposed DC voltages. Some conclusions can be drawn that the comprehensive effect of harmonic voltage and thermal aging can significantly enhance the de-trapping of the surface charge in deep traps, the deep trap energy level density is greatly affected by the proportion of harmonic. As the thermal aging time is prolonged, the trapped charge becomes more difficult to detrap, the charge accumulation increases.","PeriodicalId":7083,"journal":{"name":"2021 International Conference on Electrical Materials and Power Equipment (ICEMPE)","volume":"62 1","pages":"1-4"},"PeriodicalIF":0.0000,"publicationDate":"2021-04-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Thermal Aging Dependent Surface Charge Characteristics of Fluorinated Oil-paper Insulation Under the Harmonic Superimposed DC Voltages\",\"authors\":\"Wenbo Zhu, M. Fu, S. Hou, B. Hui, Yifan Zhang, B. Feng, Jun Chen, Le Gu, Huihong Huang\",\"doi\":\"10.1109/ICEMPE51623.2021.9509134\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The oil-impregnated paper in the converter transformer, especially in the valve side bushing, is suffered by the complicated electric field. By reason of the power electronics and non-linear equipment, the oil-impregnated paper is subject to the harmonic voltages. The insulating aging is more prominent in contrast with the power transformer. Under this condition, the charges are capable to accumulate on the surface of oil-impregnated paper, which will lead to the distorting the electric field and accelerating the insulating degradation. Consequently, the performance deterioration of oil-paper insulation is inevitable. Surface fluorination is an effective approach of modifying the chemical components of polymer matrix. Hence, this paper is dedicated to research effects of thermal aging on the surface charge dynamic characteristics of fluorinated oil-paper insulation under the harmonic superimposed DC voltages. Some conclusions can be drawn that the comprehensive effect of harmonic voltage and thermal aging can significantly enhance the de-trapping of the surface charge in deep traps, the deep trap energy level density is greatly affected by the proportion of harmonic. As the thermal aging time is prolonged, the trapped charge becomes more difficult to detrap, the charge accumulation increases.\",\"PeriodicalId\":7083,\"journal\":{\"name\":\"2021 International Conference on Electrical Materials and Power Equipment (ICEMPE)\",\"volume\":\"62 1\",\"pages\":\"1-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-04-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 International Conference on Electrical Materials and Power Equipment (ICEMPE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEMPE51623.2021.9509134\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 International Conference on Electrical Materials and Power Equipment (ICEMPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEMPE51623.2021.9509134","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

换流变压器中浸渍油纸,特别是阀侧衬套中的浸渍油纸,受到复杂电场的作用。由于电力电子和非线性设备的原因,油浸纸易受谐波电压的影响。与电力变压器相比,绝缘老化更为突出。在这种情况下,电荷会积聚在油浸纸表面,导致电场扭曲,加速绝缘退化。因此,油纸绝缘材料的性能恶化是不可避免的。表面氟化是改性聚合物基体化学成分的一种有效方法。因此,本文致力于研究谐波叠加直流电压下热老化对氟化油纸绝缘表面电荷动态特性的影响。结果表明,谐波电压和热老化的综合作用能显著增强深阱中表面电荷的脱陷,深阱能级密度受谐波比例的影响较大。随着热老化时间的延长,被困电荷的脱陷难度增大,电荷积累量增大。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Thermal Aging Dependent Surface Charge Characteristics of Fluorinated Oil-paper Insulation Under the Harmonic Superimposed DC Voltages
The oil-impregnated paper in the converter transformer, especially in the valve side bushing, is suffered by the complicated electric field. By reason of the power electronics and non-linear equipment, the oil-impregnated paper is subject to the harmonic voltages. The insulating aging is more prominent in contrast with the power transformer. Under this condition, the charges are capable to accumulate on the surface of oil-impregnated paper, which will lead to the distorting the electric field and accelerating the insulating degradation. Consequently, the performance deterioration of oil-paper insulation is inevitable. Surface fluorination is an effective approach of modifying the chemical components of polymer matrix. Hence, this paper is dedicated to research effects of thermal aging on the surface charge dynamic characteristics of fluorinated oil-paper insulation under the harmonic superimposed DC voltages. Some conclusions can be drawn that the comprehensive effect of harmonic voltage and thermal aging can significantly enhance the de-trapping of the surface charge in deep traps, the deep trap energy level density is greatly affected by the proportion of harmonic. As the thermal aging time is prolonged, the trapped charge becomes more difficult to detrap, the charge accumulation increases.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信