利用DVR提高DFIG风力机LVRT/HVRT性能

F. Bouaziz, A. Abdelkafi, Abdelkarim Masmoudi, L. Krichen
{"title":"利用DVR提高DFIG风力机LVRT/HVRT性能","authors":"F. Bouaziz, A. Abdelkafi, Abdelkarim Masmoudi, L. Krichen","doi":"10.1109/IC_ASET53395.2022.9765942","DOIUrl":null,"url":null,"abstract":"This paper proposes a method that improved the efficiency of a doubly fed induction generator (DFIG) in the case of network voltage imbalance. In the suggested configuration, a dynamic voltage restorer (DVR) is combined in series to the terminal system allowing compensating two types of fault LVRT/HVRT. The DVR device has the ability to compensate the stator voltage by injecting the appropriate at the stator that leads to keeping the generator terminal voltage at the normal level and improving the fault ride-through (FRT) ability of DFIG. Simulations in MATLAB/Simulink for a DFIG are used to verify the efficiency of the suggested control method on both types of faults.","PeriodicalId":6874,"journal":{"name":"2022 5th International Conference on Advanced Systems and Emergent Technologies (IC_ASET)","volume":"76 1","pages":"555-559"},"PeriodicalIF":0.0000,"publicationDate":"2022-03-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Improved LVRT/HVRT Capability Of DFIG Wind Turbine Using DVR\",\"authors\":\"F. Bouaziz, A. Abdelkafi, Abdelkarim Masmoudi, L. Krichen\",\"doi\":\"10.1109/IC_ASET53395.2022.9765942\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes a method that improved the efficiency of a doubly fed induction generator (DFIG) in the case of network voltage imbalance. In the suggested configuration, a dynamic voltage restorer (DVR) is combined in series to the terminal system allowing compensating two types of fault LVRT/HVRT. The DVR device has the ability to compensate the stator voltage by injecting the appropriate at the stator that leads to keeping the generator terminal voltage at the normal level and improving the fault ride-through (FRT) ability of DFIG. Simulations in MATLAB/Simulink for a DFIG are used to verify the efficiency of the suggested control method on both types of faults.\",\"PeriodicalId\":6874,\"journal\":{\"name\":\"2022 5th International Conference on Advanced Systems and Emergent Technologies (IC_ASET)\",\"volume\":\"76 1\",\"pages\":\"555-559\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-03-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 5th International Conference on Advanced Systems and Emergent Technologies (IC_ASET)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IC_ASET53395.2022.9765942\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 5th International Conference on Advanced Systems and Emergent Technologies (IC_ASET)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IC_ASET53395.2022.9765942","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

提出了一种在电网电压不平衡情况下提高双馈感应发电机效率的方法。在建议的配置中,动态电压恢复器(DVR)串联到终端系统中,可以补偿两种故障LVRT/HVRT。DVR装置具有补偿定子电压的能力,通过向定子注入适当的电压,使发电机端电压保持在正常水平,提高了DFIG的故障穿越能力。在MATLAB/Simulink中对一台DFIG进行了仿真,验证了所提出的控制方法对两种故障的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Improved LVRT/HVRT Capability Of DFIG Wind Turbine Using DVR
This paper proposes a method that improved the efficiency of a doubly fed induction generator (DFIG) in the case of network voltage imbalance. In the suggested configuration, a dynamic voltage restorer (DVR) is combined in series to the terminal system allowing compensating two types of fault LVRT/HVRT. The DVR device has the ability to compensate the stator voltage by injecting the appropriate at the stator that leads to keeping the generator terminal voltage at the normal level and improving the fault ride-through (FRT) ability of DFIG. Simulations in MATLAB/Simulink for a DFIG are used to verify the efficiency of the suggested control method on both types of faults.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信