尼日利亚西南部Ado-Ekiti addebayo地区电信桅杆地下水对柴油污染脆弱性的地球物理评估

O. Olayiwola, Fagbemigun Tokunbo, Ojo Bosede, A. Joel, Oyebamiji Ajibola
{"title":"尼日利亚西南部Ado-Ekiti addebayo地区电信桅杆地下水对柴油污染脆弱性的地球物理评估","authors":"O. Olayiwola, Fagbemigun Tokunbo, Ojo Bosede, A. Joel, Oyebamiji Ajibola","doi":"10.2478/ast-2021-0001","DOIUrl":null,"url":null,"abstract":"Abstract An appraisal of the groundwater vulnerability to contamination risk at Adebayo in Ado-Ekiti, Southwestern Nigeria, was carried out using the electrical resistivity method of geophysical prospecting. Two traverses of length 100 m each were established for both vertical electrical sounding (VES) and dipole-dipole. Six (6) Vertical Electrical Sounding (VES) and 2-D dipole-dipole profiling techniques of the electrical resistivity method were adopted for the geophysical investigation. The results show variations in resistivity values, depicting four to five geologic layers: the topsoil, laterite, weathered layer, fractured, and the fresh basement. It was observed from the correlation of the geoelectric section and 2-D resistivity image along traverse 1 (TR1) that the groundwater in the study area flows towards the southwestern part, and the fractured basement serves as a migration pathway to the diesel oil in the same direction as groundwater flow. The fractured basement (Well 2) with no lateritic cover has higher resistivity values compare to the fracture zone that was found directly under the mast which was overlain by the laterite. Comparing the resistivity values of Well 1 and 2, Well 2 that was drilled into the fractured basement has more traces of the contaminant than Well 1.","PeriodicalId":7998,"journal":{"name":"Annals of Science and Technology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Geophysical Assessment of Groundwater Vulnerability to Diesel Contamination at a Telecommunication Mast in Adebayo Area, Ado-Ekiti, Southwestern Nigeria\",\"authors\":\"O. Olayiwola, Fagbemigun Tokunbo, Ojo Bosede, A. Joel, Oyebamiji Ajibola\",\"doi\":\"10.2478/ast-2021-0001\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract An appraisal of the groundwater vulnerability to contamination risk at Adebayo in Ado-Ekiti, Southwestern Nigeria, was carried out using the electrical resistivity method of geophysical prospecting. Two traverses of length 100 m each were established for both vertical electrical sounding (VES) and dipole-dipole. Six (6) Vertical Electrical Sounding (VES) and 2-D dipole-dipole profiling techniques of the electrical resistivity method were adopted for the geophysical investigation. The results show variations in resistivity values, depicting four to five geologic layers: the topsoil, laterite, weathered layer, fractured, and the fresh basement. It was observed from the correlation of the geoelectric section and 2-D resistivity image along traverse 1 (TR1) that the groundwater in the study area flows towards the southwestern part, and the fractured basement serves as a migration pathway to the diesel oil in the same direction as groundwater flow. The fractured basement (Well 2) with no lateritic cover has higher resistivity values compare to the fracture zone that was found directly under the mast which was overlain by the laterite. Comparing the resistivity values of Well 1 and 2, Well 2 that was drilled into the fractured basement has more traces of the contaminant than Well 1.\",\"PeriodicalId\":7998,\"journal\":{\"name\":\"Annals of Science and Technology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annals of Science and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2478/ast-2021-0001\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/ast-2021-0001","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

摘要利用地球物理勘探中的电阻率法,对尼日利亚西南部Ado-Ekiti地区Adebayo地区地下水污染风险脆弱性进行了评价。垂直电测深(VES)和偶极子-偶极子测深分别建立了两条长度为100 m的导线。地球物理调查采用了六(6)垂直电测深(VES)和电阻率法的二维偶极-偶极剖面技术。结果显示电阻率值的变化,描绘了四到五个地质层:表土、红土、风化层、裂缝和新鲜基底。通过地电剖面与沿导线1 (TR1)的二维电阻率成像对比发现,研究区地下水向西南方向流动,断裂基底与地下水流动方向相同,是柴油运移的通道。没有红土覆盖的裂缝基底(井2)的电阻率值高于井架下方被红土覆盖的裂缝带。对比井1和井2的电阻率值,井2钻入裂缝基底,比井1有更多的污染物痕迹。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Geophysical Assessment of Groundwater Vulnerability to Diesel Contamination at a Telecommunication Mast in Adebayo Area, Ado-Ekiti, Southwestern Nigeria
Abstract An appraisal of the groundwater vulnerability to contamination risk at Adebayo in Ado-Ekiti, Southwestern Nigeria, was carried out using the electrical resistivity method of geophysical prospecting. Two traverses of length 100 m each were established for both vertical electrical sounding (VES) and dipole-dipole. Six (6) Vertical Electrical Sounding (VES) and 2-D dipole-dipole profiling techniques of the electrical resistivity method were adopted for the geophysical investigation. The results show variations in resistivity values, depicting four to five geologic layers: the topsoil, laterite, weathered layer, fractured, and the fresh basement. It was observed from the correlation of the geoelectric section and 2-D resistivity image along traverse 1 (TR1) that the groundwater in the study area flows towards the southwestern part, and the fractured basement serves as a migration pathway to the diesel oil in the same direction as groundwater flow. The fractured basement (Well 2) with no lateritic cover has higher resistivity values compare to the fracture zone that was found directly under the mast which was overlain by the laterite. Comparing the resistivity values of Well 1 and 2, Well 2 that was drilled into the fractured basement has more traces of the contaminant than Well 1.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信