三维经食管超声心动图在机械假体功能障碍诊断中的作用

IF 1.7 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
V. Scollo, G. Fede, G. Abate, P. Belluardo, N. Guccione, G. Sulsenti, S. Ficili
{"title":"三维经食管超声心动图在机械假体功能障碍诊断中的作用","authors":"V. Scollo, G. Fede, G. Abate, P. Belluardo, N. Guccione, G. Sulsenti, S. Ficili","doi":"10.1093/eurheartjsupp/suad111.346","DOIUrl":null,"url":null,"abstract":"\n Infections with endocardial vegetation or the exuberant growth of neoendothelialization tissue (cloth –tissue overgrowth) in heart valve prostheses lead, among other complications, to the malfunction of the prostheses themselves due to obstruction. Among the diagnostic methods available to us, to achieve the diagnosis of prosthetic dysfunction, in recent years three–dimensional transesophageal echocardiography (3D TTE) has become increasingly imposed. We present two clinical cases of patients admitted to our Cardiology department Case 1: Patient of 62 years old, hospitalized for established congestive heart failure. In 2006 he underwent ascending aorta replacement with Dacron 28 prosthesis and aortic valve replacement with mechanical prosthesis (Sorin 25) for aortic bicuspid and ascending aortic aneurysm. During the last follow–up was observed a slight increase in the value of intraprosthetic gradients, as well as a variability in INR values. Physical examination showed signs of heart failure (NT–ProBNP >1000 pg/ml); normal inflammation indices (PCR <2.9 mg/l); ECG: sinus rhythm at 85 bpm with left ventricular overload; trans–thoracic echocardiography showed severe intraprosthetic aortic gradient (Gmax 132mmHg–Gmed 72mmHg), doubtful for cloth adhered to prosthetic discs; 3D TTE shoved hyperechoreflective image adhered to the posterior mobile element (5x9mm) which was fixed in semi–closure. Subsequently, the patient underwent prosthetic replacement surgery with biological prosthesis. Case 2: Patient of 67 years old, heavy smoker, hypertensive, with aortic mechanical prosthesis, a few weeks before hospitalized for Corynebacterium Jeikeium infection. Hospitalized again for fever with increased inflammation indices (CRP 202mg/l). A first TTE concluded for suspected endocarditis of the prosthesis; this doubt was also dissolved by 3D TTE which showed a soft protruding image of the posterior mobile element, preventing the opening and determining severe stenosis (Gmax 160mmHg–Gmed of 80 mmHg), so this patients was transferred to the cardiac surgery department.\n \n \n 3D TTE is a method of rapid and safe execution that can be exploited not only pre– or intraoperatively but also to settle diagnostic suspicions not clarified by traditional 2d methods, even managing to distinguish cloth deposits from vegetation / abscesses.\n","PeriodicalId":11956,"journal":{"name":"European Heart Journal Supplements","volume":"51 1","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"P272 ROLE OF 3D TRANSESOPHAGEAL ECHOCARDIOGRAPHY IN DIANOSIS OF DYSFUNCTION OF MECHANICAL PROSTHESES\",\"authors\":\"V. Scollo, G. Fede, G. Abate, P. Belluardo, N. Guccione, G. Sulsenti, S. Ficili\",\"doi\":\"10.1093/eurheartjsupp/suad111.346\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n Infections with endocardial vegetation or the exuberant growth of neoendothelialization tissue (cloth –tissue overgrowth) in heart valve prostheses lead, among other complications, to the malfunction of the prostheses themselves due to obstruction. Among the diagnostic methods available to us, to achieve the diagnosis of prosthetic dysfunction, in recent years three–dimensional transesophageal echocardiography (3D TTE) has become increasingly imposed. We present two clinical cases of patients admitted to our Cardiology department Case 1: Patient of 62 years old, hospitalized for established congestive heart failure. In 2006 he underwent ascending aorta replacement with Dacron 28 prosthesis and aortic valve replacement with mechanical prosthesis (Sorin 25) for aortic bicuspid and ascending aortic aneurysm. During the last follow–up was observed a slight increase in the value of intraprosthetic gradients, as well as a variability in INR values. Physical examination showed signs of heart failure (NT–ProBNP >1000 pg/ml); normal inflammation indices (PCR <2.9 mg/l); ECG: sinus rhythm at 85 bpm with left ventricular overload; trans–thoracic echocardiography showed severe intraprosthetic aortic gradient (Gmax 132mmHg–Gmed 72mmHg), doubtful for cloth adhered to prosthetic discs; 3D TTE shoved hyperechoreflective image adhered to the posterior mobile element (5x9mm) which was fixed in semi–closure. Subsequently, the patient underwent prosthetic replacement surgery with biological prosthesis. Case 2: Patient of 67 years old, heavy smoker, hypertensive, with aortic mechanical prosthesis, a few weeks before hospitalized for Corynebacterium Jeikeium infection. Hospitalized again for fever with increased inflammation indices (CRP 202mg/l). A first TTE concluded for suspected endocarditis of the prosthesis; this doubt was also dissolved by 3D TTE which showed a soft protruding image of the posterior mobile element, preventing the opening and determining severe stenosis (Gmax 160mmHg–Gmed of 80 mmHg), so this patients was transferred to the cardiac surgery department.\\n \\n \\n 3D TTE is a method of rapid and safe execution that can be exploited not only pre– or intraoperatively but also to settle diagnostic suspicions not clarified by traditional 2d methods, even managing to distinguish cloth deposits from vegetation / abscesses.\\n\",\"PeriodicalId\":11956,\"journal\":{\"name\":\"European Heart Journal Supplements\",\"volume\":\"51 1\",\"pages\":\"\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2023-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Heart Journal Supplements\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1093/eurheartjsupp/suad111.346\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Heart Journal Supplements","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/eurheartjsupp/suad111.346","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

心内膜植被感染或心脏瓣膜假体中新内皮化组织的旺盛生长(布组织过度生长),除其他并发症外,还会导致假体本身因阻塞而发生功能障碍。在我们现有的诊断方法中,为了实现对义肢功能障碍的诊断,近年来,三维经食管超声心动图(3D TTE)被越来越多地采用。我们提出两例临床病例的病人住进我们的心内科病例1:病人62岁,住院建立充血性心力衰竭。2006年因主动脉二尖瓣和升主动脉瘤行涤纶28假体的升主动脉置换术和索林25机械假体的主动脉瓣置换术。在最后一次随访中,观察到假体内梯度值略有增加,以及INR值的变异性。体格检查显示心衰迹象(NT-ProBNP >1000 pg/ml);炎症指标正常(PCR <2.9 mg/l);心电图:窦性心律85 bpm伴左心室负荷过重;经胸超声心动图显示假体内主动脉梯度严重(Gmax 132mmHg-Gmed 72mmHg),怀疑布粘附假体椎间盘;三维TTE推高反射影像粘附于半闭合固定的后部活动单元(5x9mm)。随后,患者接受了生物假体置换手术。病例2:患者67岁,重度吸烟者,高血压,主动脉机械假体,入院前数周因杰氏棒状杆菌感染。再次住院发热,炎症指数升高(CRP 202mg/l)。第一例疑似假体心内膜炎的TTE结论;3D TTE显示后活动元件软凸出,阻止打开,确定狭窄严重(Gmax 160mmHg-Gmed 80 mmHg),消除了这一怀疑,将患者转至心脏外科。3D TTE是一种快速安全的执行方法,不仅可以在术前或术中使用,还可以解决传统2d方法无法澄清的诊断怀疑,甚至可以区分布沉积物和植被/脓肿。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
P272 ROLE OF 3D TRANSESOPHAGEAL ECHOCARDIOGRAPHY IN DIANOSIS OF DYSFUNCTION OF MECHANICAL PROSTHESES
Infections with endocardial vegetation or the exuberant growth of neoendothelialization tissue (cloth –tissue overgrowth) in heart valve prostheses lead, among other complications, to the malfunction of the prostheses themselves due to obstruction. Among the diagnostic methods available to us, to achieve the diagnosis of prosthetic dysfunction, in recent years three–dimensional transesophageal echocardiography (3D TTE) has become increasingly imposed. We present two clinical cases of patients admitted to our Cardiology department Case 1: Patient of 62 years old, hospitalized for established congestive heart failure. In 2006 he underwent ascending aorta replacement with Dacron 28 prosthesis and aortic valve replacement with mechanical prosthesis (Sorin 25) for aortic bicuspid and ascending aortic aneurysm. During the last follow–up was observed a slight increase in the value of intraprosthetic gradients, as well as a variability in INR values. Physical examination showed signs of heart failure (NT–ProBNP >1000 pg/ml); normal inflammation indices (PCR <2.9 mg/l); ECG: sinus rhythm at 85 bpm with left ventricular overload; trans–thoracic echocardiography showed severe intraprosthetic aortic gradient (Gmax 132mmHg–Gmed 72mmHg), doubtful for cloth adhered to prosthetic discs; 3D TTE shoved hyperechoreflective image adhered to the posterior mobile element (5x9mm) which was fixed in semi–closure. Subsequently, the patient underwent prosthetic replacement surgery with biological prosthesis. Case 2: Patient of 67 years old, heavy smoker, hypertensive, with aortic mechanical prosthesis, a few weeks before hospitalized for Corynebacterium Jeikeium infection. Hospitalized again for fever with increased inflammation indices (CRP 202mg/l). A first TTE concluded for suspected endocarditis of the prosthesis; this doubt was also dissolved by 3D TTE which showed a soft protruding image of the posterior mobile element, preventing the opening and determining severe stenosis (Gmax 160mmHg–Gmed of 80 mmHg), so this patients was transferred to the cardiac surgery department. 3D TTE is a method of rapid and safe execution that can be exploited not only pre– or intraoperatively but also to settle diagnostic suspicions not clarified by traditional 2d methods, even managing to distinguish cloth deposits from vegetation / abscesses.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
European Heart Journal Supplements
European Heart Journal Supplements 医学-心血管系统
CiteScore
3.00
自引率
0.00%
发文量
575
审稿时长
12 months
期刊介绍: The European Heart Journal Supplements (EHJs) is a long standing member of the ESC Journal Family that serves as a publication medium for supplemental issues of the flagship European Heart Journal. Traditionally EHJs published a broad range of articles from symposia to special issues on specific topics of interest. The Editor-in-Chief, Professor Roberto Ferrari, together with his team of eminent Associate Editors: Professor Francisco Fernández-Avilés, Professors Jeroen Bax, Michael Böhm, Frank Ruschitzka, and Thomas Lüscher from the European Heart Journal, has implemented a change of focus for the journal. This entirely refreshed version of the European Heart Journal Supplements now bears the subtitle the Heart of the Matter to give recognition to the focus the journal now has. The EHJs – the Heart of the Matter intends to offer a dedicated, scientific space for the ESC, Institutions, National and Affiliate Societies, Associations, Working Groups and Councils to disseminate their important successes globally.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信