硝酸、二氧化硫和大气颗粒的几种综合采样方法的表征

K. Anlauf, H. Wiebe, P. Fellin
{"title":"硝酸、二氧化硫和大气颗粒的几种综合采样方法的表征","authors":"K. Anlauf, H. Wiebe, P. Fellin","doi":"10.1080/00022470.1986.10466107","DOIUrl":null,"url":null,"abstract":"Laboratory and field experiments were performed to evaluate integrative measurement methods for atmospheric nitrates, sulphate and sulphur dioxide. Denuder tubes and several filter media were tested under laboratory and field conditions. Effects of sampling variables such as temperature and relative humidity, flow rates, concentration, loading capacity and artifacts due to NO, NO2 and SO2 were also evaluated. The integrative filter sampling method and the ion chromatographic analytical procedure gave a measurement precision (relative standard deviation) of ±11.5 percent for particulate NO3 − on Teflon and ±15.6 percent for gaseous HNO3 on nylon; for both these constituents, the detection limit was about 0.1 μ m−3.","PeriodicalId":17188,"journal":{"name":"Journal of the Air Pollution Control Association","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1986-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"39","resultStr":"{\"title\":\"Characterization of several integrative sampling methods for nitric acid, sulphur dioxide and atmospheric particles\",\"authors\":\"K. Anlauf, H. Wiebe, P. Fellin\",\"doi\":\"10.1080/00022470.1986.10466107\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Laboratory and field experiments were performed to evaluate integrative measurement methods for atmospheric nitrates, sulphate and sulphur dioxide. Denuder tubes and several filter media were tested under laboratory and field conditions. Effects of sampling variables such as temperature and relative humidity, flow rates, concentration, loading capacity and artifacts due to NO, NO2 and SO2 were also evaluated. The integrative filter sampling method and the ion chromatographic analytical procedure gave a measurement precision (relative standard deviation) of ±11.5 percent for particulate NO3 − on Teflon and ±15.6 percent for gaseous HNO3 on nylon; for both these constituents, the detection limit was about 0.1 μ m−3.\",\"PeriodicalId\":17188,\"journal\":{\"name\":\"Journal of the Air Pollution Control Association\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1986-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"39\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the Air Pollution Control Association\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/00022470.1986.10466107\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Air Pollution Control Association","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/00022470.1986.10466107","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 39

摘要

进行了实验室和实地试验,以评估大气硝酸盐、硫酸盐和二氧化硫的综合测量方法。在实验室和现场条件下对灯芯管和几种过滤介质进行了测试。采样变量的影响,如温度和相对湿度,流量,浓度,负载能力和人工制品由于NO, NO2和SO2也进行了评估。综合过滤取样法和离子色谱分析方法对聚四氟乙烯上的NO3 -颗粒的测量精度(相对标准偏差)为±11.5%,对尼龙上的HNO3气体的测量精度为±15.6%;这两种成分的检出限均在0.1 μ m−3左右。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Characterization of several integrative sampling methods for nitric acid, sulphur dioxide and atmospheric particles
Laboratory and field experiments were performed to evaluate integrative measurement methods for atmospheric nitrates, sulphate and sulphur dioxide. Denuder tubes and several filter media were tested under laboratory and field conditions. Effects of sampling variables such as temperature and relative humidity, flow rates, concentration, loading capacity and artifacts due to NO, NO2 and SO2 were also evaluated. The integrative filter sampling method and the ion chromatographic analytical procedure gave a measurement precision (relative standard deviation) of ±11.5 percent for particulate NO3 − on Teflon and ±15.6 percent for gaseous HNO3 on nylon; for both these constituents, the detection limit was about 0.1 μ m−3.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信