{"title":"海上电力系统中异型发电机中性点接地","authors":"S. Pragasam","doi":"10.2118/193100-MS","DOIUrl":null,"url":null,"abstract":"\n Designing neutral grounding systems for Generators require careful consideration of various aspects, which are mainly related to the Generators themselves and, also with respect to other aspects of the overall system design. More importantly, when the Generators to be operated in parallel have dissimilar design, the neutral grounding design must address a whole array of issues and technical requirements. While there are solutions to mitigate these issues, some of them are not appropriate for offshore installations.","PeriodicalId":11079,"journal":{"name":"Day 4 Thu, November 15, 2018","volume":"14 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2018-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Neutral Grounding of Dissimilar Generators in Offshore Power Systems\",\"authors\":\"S. Pragasam\",\"doi\":\"10.2118/193100-MS\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n Designing neutral grounding systems for Generators require careful consideration of various aspects, which are mainly related to the Generators themselves and, also with respect to other aspects of the overall system design. More importantly, when the Generators to be operated in parallel have dissimilar design, the neutral grounding design must address a whole array of issues and technical requirements. While there are solutions to mitigate these issues, some of them are not appropriate for offshore installations.\",\"PeriodicalId\":11079,\"journal\":{\"name\":\"Day 4 Thu, November 15, 2018\",\"volume\":\"14 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-11-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Day 4 Thu, November 15, 2018\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2118/193100-MS\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Day 4 Thu, November 15, 2018","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2118/193100-MS","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Neutral Grounding of Dissimilar Generators in Offshore Power Systems
Designing neutral grounding systems for Generators require careful consideration of various aspects, which are mainly related to the Generators themselves and, also with respect to other aspects of the overall system design. More importantly, when the Generators to be operated in parallel have dissimilar design, the neutral grounding design must address a whole array of issues and technical requirements. While there are solutions to mitigate these issues, some of them are not appropriate for offshore installations.