影响气提法污水处理厂氨氮去除效率的影响因素研究

A. Zangeneh, S. Sabzalipour, A. Takdastan, R. J. Yengejeh, Morteza Abullatif Khafaie
{"title":"影响气提法污水处理厂氨氮去除效率的影响因素研究","authors":"A. Zangeneh, S. Sabzalipour, A. Takdastan, R. J. Yengejeh, Morteza Abullatif Khafaie","doi":"10.22034/JEST.2021.57356.5238","DOIUrl":null,"url":null,"abstract":"Removal of ammonia from wastewater in the wastewater treatment plants due to its dangerous and toxic effects on human health and biotic resources is essential. This study was aimed to investigate the effective operational parameters on the efficiency of the air stripping process, determine their priority and degree of effect on ammonia removal and compare the ammonia removal efficiency during the air stripping process in the municipal treatment plants using synthetic and real wastewater.In this study, the effect of each operating parameter on the ammonia removal efficiency including initial ammonia concentration, pH and temperature during the air stripping process for synthetic and real wastewater, respectively, based on standard methods (the Nesslerization method, preparation of standard solutions) using a spectrophotometer, pH meter and temperature module were evaluated.The results of this study showed that the maximum of ARE for synthetic wastewater with Air to water ratio 80 and an initial ammonia concentration of 59. 6 mg /l, pH 12.05 and temperature 46.3°C was %91. Also, the results of the study on the ARE during the air stripping process showed that the maximum of ARE (%91) for real wastewater (primary sedimentation tank effluent (PST)) with Air to water ratio 80 and an initial ammonia concentration of 61.04 mg/l, pH 12.53 and temperature 45.9 ° C was obtained.Based on the results of univariate regression model, initial ammonia concentration˃ temperature˃ pH have the greatest effect on the ammonia removal efficiency in synthetic wastewater and real wastewater, respectively. In the multivariate regression model, the effect of temperature and pH on the ammonia removal efficiency in synthetic and real wastewater is increasing and decreasing, respectively. Based on the findings of this study, the air stripping process can be successfully used to remove ammonia from wastewater in the municipal treatment plants, especially in the tropics.","PeriodicalId":15762,"journal":{"name":"Journal of Environmental Science and Technology","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-02-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Investigation of effective factors on the ammonia removal efficiency in the wastewater treatment plants using the air stripping process\",\"authors\":\"A. Zangeneh, S. Sabzalipour, A. Takdastan, R. J. Yengejeh, Morteza Abullatif Khafaie\",\"doi\":\"10.22034/JEST.2021.57356.5238\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Removal of ammonia from wastewater in the wastewater treatment plants due to its dangerous and toxic effects on human health and biotic resources is essential. This study was aimed to investigate the effective operational parameters on the efficiency of the air stripping process, determine their priority and degree of effect on ammonia removal and compare the ammonia removal efficiency during the air stripping process in the municipal treatment plants using synthetic and real wastewater.In this study, the effect of each operating parameter on the ammonia removal efficiency including initial ammonia concentration, pH and temperature during the air stripping process for synthetic and real wastewater, respectively, based on standard methods (the Nesslerization method, preparation of standard solutions) using a spectrophotometer, pH meter and temperature module were evaluated.The results of this study showed that the maximum of ARE for synthetic wastewater with Air to water ratio 80 and an initial ammonia concentration of 59. 6 mg /l, pH 12.05 and temperature 46.3°C was %91. Also, the results of the study on the ARE during the air stripping process showed that the maximum of ARE (%91) for real wastewater (primary sedimentation tank effluent (PST)) with Air to water ratio 80 and an initial ammonia concentration of 61.04 mg/l, pH 12.53 and temperature 45.9 ° C was obtained.Based on the results of univariate regression model, initial ammonia concentration˃ temperature˃ pH have the greatest effect on the ammonia removal efficiency in synthetic wastewater and real wastewater, respectively. In the multivariate regression model, the effect of temperature and pH on the ammonia removal efficiency in synthetic and real wastewater is increasing and decreasing, respectively. Based on the findings of this study, the air stripping process can be successfully used to remove ammonia from wastewater in the municipal treatment plants, especially in the tropics.\",\"PeriodicalId\":15762,\"journal\":{\"name\":\"Journal of Environmental Science and Technology\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-02-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Environmental Science and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.22034/JEST.2021.57356.5238\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Environmental Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22034/JEST.2021.57356.5238","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

由于氨对人类健康和生物资源具有危险和毒性影响,废水处理厂必须从废水中去除氨。本研究旨在探讨影响空气汽提工艺效率的有效操作参数,确定其对氨氮去除的优先级和影响程度,并比较城市污水处理厂使用合成废水和真实废水进行空气汽提工艺的氨氮去除效率。本研究采用分光光度计、pH计和温度模块,分别以标准方法(neslerization法、标准溶液制备)为基础,评价了合成废水和真实废水气提过程中初始氨浓度、pH值和温度等各操作参数对氨脱效率的影响。本研究结果表明,当空气与水比为80、初始氨浓度为59时,合成废水的最大ARE。6 mg /l, pH 12.05,温度46.3℃,%91。同时,对气提过程的ARE进行了研究,结果表明,在空气与水比为80、初始氨浓度为61.04 mg/l、pH为12.53、温度为45.9℃的条件下,实际废水(初级沉淀池出水)的ARE最高为91%。单变量回归模型结果表明,初始氨浓度、温度、pH对合成废水和真实废水中氨的去除率影响最大。在多元回归模型中,温度和pH对合成废水和真实废水中氨氮去除率的影响分别呈增大和减小的趋势。基于本研究的结果,空气汽提工艺可以成功地用于去除城市处理厂废水中的氨,特别是在热带地区。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Investigation of effective factors on the ammonia removal efficiency in the wastewater treatment plants using the air stripping process
Removal of ammonia from wastewater in the wastewater treatment plants due to its dangerous and toxic effects on human health and biotic resources is essential. This study was aimed to investigate the effective operational parameters on the efficiency of the air stripping process, determine their priority and degree of effect on ammonia removal and compare the ammonia removal efficiency during the air stripping process in the municipal treatment plants using synthetic and real wastewater.In this study, the effect of each operating parameter on the ammonia removal efficiency including initial ammonia concentration, pH and temperature during the air stripping process for synthetic and real wastewater, respectively, based on standard methods (the Nesslerization method, preparation of standard solutions) using a spectrophotometer, pH meter and temperature module were evaluated.The results of this study showed that the maximum of ARE for synthetic wastewater with Air to water ratio 80 and an initial ammonia concentration of 59. 6 mg /l, pH 12.05 and temperature 46.3°C was %91. Also, the results of the study on the ARE during the air stripping process showed that the maximum of ARE (%91) for real wastewater (primary sedimentation tank effluent (PST)) with Air to water ratio 80 and an initial ammonia concentration of 61.04 mg/l, pH 12.53 and temperature 45.9 ° C was obtained.Based on the results of univariate regression model, initial ammonia concentration˃ temperature˃ pH have the greatest effect on the ammonia removal efficiency in synthetic wastewater and real wastewater, respectively. In the multivariate regression model, the effect of temperature and pH on the ammonia removal efficiency in synthetic and real wastewater is increasing and decreasing, respectively. Based on the findings of this study, the air stripping process can be successfully used to remove ammonia from wastewater in the municipal treatment plants, especially in the tropics.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信